Signal quality of biometry in silicone oil-filled eyes using partial coherence laser interferometry

التفاصيل البيبلوغرافية
العنوان: Signal quality of biometry in silicone oil-filled eyes using partial coherence laser interferometry
المؤلفون: Philipp C. Jacobi, Thomas S. Dietlein, Christoph Lüke, Sigrid Roters, S. Dinslage, Guenter K. Krieglstein, Peter Walter, Gernot F Roessler
المصدر: Journal of cataract and refractive surgery. 31(5)
سنة النشر: 2004
مصطلحات موضوعية: medicine.medical_specialty, Biometry, genetic structures, Pseudophakia, medicine.medical_treatment, Intraocular lens, Eye, Refraction, Ocular, chemistry.chemical_compound, Silicone, Retinal Diseases, Ophthalmology, medicine, Humans, Silicone Oils, Body Weights and Measures, business.industry, Lasers, Retinal detachment, Cataract surgery, medicine.disease, Refraction, eye diseases, Sensory Systems, Silicone oil, Interferometry, chemistry, Vitreous hemorrhage, Surgery, sense organs, Tamponade, business
الوصف: Purpose To assess the practical feasibility and signal quality of axial length measurements by partial coherence laser interferometry in silicone oil–filled eyes with previous complicated vitreoretinal surgery. Settings Department of Ophthalmology, University Cologne, Cologne, Germany. Methods Using a Zeiss IOLMaster, axial length measurements and signal-to-noise ratios of optical biometry in silicone oil–filled eyes (n=45) and contralateral eyes without tamponade (n=41) were analyzed. Results Axial length measurements with signal-to-noise ratio ≥2 were feasible in 41 of 45 silicone oil–filled eyes (91%) and 37 of 41 eyes without tamponade (90%). Cataract, central retinal detachment, vitreous hemorrhage, and emulsified oil droplets attached to the intraocular lens were reasons for failure of partial coherence laser interferometry. The signal-to-noise ratio of the first 2 measurements was significantly smaller ( P =.04) in silicone-filled eyes (4.4 ± 2.0) than in eyes without tamponade (5.5 ± 3.0). Axial lengths of the oil–filled eye and the contralateral eye showed a significant intraindividual correlation ( P r =0.84). Conclusions Partial coherence laser interferometry shows good clinical practicability in silicone oil–filled eyes with previous complicated vitreoretinal surgery. Further studies are needed to assess the reliability of these measurements with regard to postoperative refraction after combined oil removal and cataract surgery.
تدمد: 0886-3350
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::264231b94d8afc3735589cc8e6bf2d85Test
https://pubmed.ncbi.nlm.nih.gov/15975470Test
حقوق: CLOSED
رقم الانضمام: edsair.doi.dedup.....264231b94d8afc3735589cc8e6bf2d85
قاعدة البيانات: OpenAIRE