Development of a fast kinetic method for the determination of carboxypeptidase U (TAFIa) using C-terminal arginine containing peptides as substrate

التفاصيل البيبلوغرافية
العنوان: Development of a fast kinetic method for the determination of carboxypeptidase U (TAFIa) using C-terminal arginine containing peptides as substrate
المؤلفون: J. L. Willemse, Dirk Hendriks, Robert Verkerk, Judith Leurs
المصدر: Analytical biochemistry
سنة النشر: 2004
مصطلحات موضوعية: Carboxypeptidase B2, Time Factors, Arginine, Pyruvate Kinase, Biophysics, Peptide, Bradykinin, Biochemistry, Sensitivity and Specificity, Substrate Specificity, Zymogen, Amino Acid Sequence, Molecular Biology, Peptide sequence, Chromatography, High Pressure Liquid, chemistry.chemical_classification, Enzyme Precursors, biology, L-Lactate Dehydrogenase, Substrate (chemistry), Reproducibility of Results, Cell Biology, Arginine Kinase, Arginine kinase, Kinetics, Enzyme, chemistry, biology.protein, Tuftsin, Peptides, Pyruvate kinase
الوصف: Carboxypeptidase U (CPU, TAFIa) is a novel determinant of the fibrinolytic rate. It circulates in blood as an inactive zymogen, procarboxypeptidase U, which is activated during the process of coagulation and fibrinolysis. CPU has a very short half-life at 37 degrees C. Its intrinsic instability complicates the determination of kinetic parameters of different substrates using an endpoint method. We developed a fast kinetic assay for measuring continuously the release of the C-terminal arginine by CPU independent of the nature of the substrate peptide used, allowing us to perform substrate specificity studies of CPU. This method uses arginine kinase, pyruvate kinase, and lactate dehydrogenase as auxiliary enzymes. The CPU activities measured using this kinetic assay were in the range of 97-103% of those determined with our HPLC-assisted reference assay, and the obtained K(m) and k(cat) values for hippuryl-l-arginine and bradykinin were in good accordance with those described in the literature. As expected, no arginine cleaving was seen using dipeptides and peptide substrates with a proline in the penultimate position. The presented kinetic assay enables the fast screening of substrates with a C-terminal arginine and is a valuable new tool for the kinetic evaluation of both synthetic and physiological substrates of CPU.
تدمد: 0003-2697
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::19acf29d7b66110aed8853eff537e55dTest
https://pubmed.ncbi.nlm.nih.gov/15802136Test
حقوق: CLOSED
رقم الانضمام: edsair.doi.dedup.....19acf29d7b66110aed8853eff537e55d
قاعدة البيانات: OpenAIRE