MR Imaging Detection of Superparamagnetic Iron Oxide–loaded Tris-acryl Embolization Microspheres

التفاصيل البيبلوغرافية
العنوان: MR Imaging Detection of Superparamagnetic Iron Oxide–loaded Tris-acryl Embolization Microspheres
المؤلفون: Michel Wassef, Julien Namur, Jean-Pierre Pelage, Denis Labarre, Alex Laurent, François Langevin, René Chapot
المصدر: Journal of Vascular and Interventional Radiology. 18:1287-1295
بيانات النشر: Elsevier BV, 2007.
سنة النشر: 2007
مصطلحات موضوعية: Tris, Pathology, medicine.medical_specialty, Swine, Iron, medicine.medical_treatment, Acrylic Resins, Kidney, Renal Circulation, Microsphere, chemistry.chemical_compound, Renal Artery, In vivo, medicine.artery, medicine, Animals, Infusions, Intra-Arterial, Radiology, Nuclear Medicine and imaging, Embolization, Particle Size, Renal artery, Sheep, medicine.diagnostic_test, business.industry, Oxides, Magnetic resonance imaging, Embolization, Therapeutic, Magnetic Resonance Imaging, Microspheres, digestive system diseases, chemistry, Gelatin, Cardiology and Cardiovascular Medicine, business, Nuclear medicine, Superparamagnetic iron oxide, Ex vivo
الوصف: Purpose To assess by magnetic resonance (MR) imaging the detectability of superparamagnetic iron oxide (SPIO)-labeled microspheres (MSs) in vitro on gelose, ex vivo in kidneys from embolized sheep, and in vivo in kidneys from embolized pigs. Materials and Methods With various sizes of SPIO-labeled MSs, common neck and pelvic spin-echo and gradient-echo sequences were acquired on a 1.5-T MR unit. SPIO-labeled MSs of four sizes were embedded in a hydrogel as single MSs or in multiple units, or multiplets. Detection rate on MR imaging was assessed according to the real size and number of MSs. SPIO-loaded and unloaded MSs of four sizes were injected into eight sheep kidneys, which underwent MR and pathologic examinations. For each size, the location of MSs in renal vasculature was determined and compared according to the technique used. Kidneys were embolized in pigs with various amounts of MSs in three sizes. MR was performed immediately after embolization and SPIO-labeled MS detection was assessed according to size, organ, and amount injected. Results SPIO-labeled MSs provide a low signal intensity on T1-weighted sequences, without distortion. In vitro, 28% of 100–300-μm single MSs were detected and more than 80% were detected for larger sizes. MS multiplets were all detected in all sizes. Ex vivo, all sizes of MSs were detected by MR imaging in kidneys, whereas control MSs were not observed. Histologic analysis showed that there was no difference in vascular distribution between SPIO-labeled MS and control MSs, and therefore for each caliber ( P > .05). Arterial location of SPIO-labeled MSs was the same on MR imaging and histologic analysis. In vivo, SPIO-labeled MS were detected in the kidney vasculature when volumes greater than 1 mL of 100–300-μm or 500–700-μm MSs were injected. Volumes lower than 1 mL SPIO-labeled MSs were hardly detected in kidneys, regardless of MS size. Conclusions SPIO-labeled MSs are detected by MR imaging with common gradient-echo sequences in vitro in gelose and ex vivo and in vivo in kidneys. SPIO-labeled MSs could allow better control of embolization and thereby enhance efficacy and safety of the procedure.
تدمد: 1051-0443
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::064dd28b90a7cc43718f4c09c1107cf7Test
https://doi.org/10.1016/j.jvir.2007.07.015Test
حقوق: CLOSED
رقم الانضمام: edsair.doi.dedup.....064dd28b90a7cc43718f4c09c1107cf7
قاعدة البيانات: OpenAIRE