Closure of the subclavian artery puncture site with a percutaneous suture device after removal of an arterial pacemaker lead
العنوان: | Closure of the subclavian artery puncture site with a percutaneous suture device after removal of an arterial pacemaker lead |
---|---|
المؤلفون: | Juergen Meyhoefer, Christian Butter, Heiko Lehmann, Hans-Heinrich Minden |
المصدر: | EP Europace. 8:1070-1072 |
بيانات النشر: | Oxford University Press (OUP), 2006. |
سنة النشر: | 2006 |
مصطلحات موضوعية: | Male, Pacemaker, Artificial, medicine.medical_specialty, Percutaneous, Subclavian Artery, Punctures, Femoral artery, Suture (anatomy), Physiology (medical), medicine.artery, Catheterization, Peripheral, Humans, Medicine, Subclavian artery, Aged, Aorta, Sutures, medicine.diagnostic_test, business.industry, Suture Techniques, Angiography, Femoral Artery, medicine.anatomical_structure, Ventricle, cardiovascular system, Radiology, Cardiology and Cardiovascular Medicine, business, Artery |
الوصف: | We describe the closure of a subclavian artery puncture site with a percutaneous suture device after removal of a pacemaker lead 1 week after its inadvertent positioning in the left ventricle via the subclavian artery. The lead was retracted from the left ventricle into the aorta and linked to a guiding catheter introduced via femoral artery access. The lead and the guiding catheter were removed from the artery to the subclavian area. This manoeuvre allowed the placement of a percutaneous arterial suture device (Perclose) to close the puncture site. |
تدمد: | 1532-2092 1099-5129 |
الوصول الحر: | https://explore.openaire.eu/search/publication?articleId=doi_dedup___::04de45761a279084ba5556b4961445faTest https://doi.org/10.1093/europace/eul129Test |
حقوق: | OPEN |
رقم الانضمام: | edsair.doi.dedup.....04de45761a279084ba5556b4961445fa |
قاعدة البيانات: | OpenAIRE |
تدمد: | 15322092 10995129 |
---|