Correlation between the concentration of TeO2and the radiation shielding properties in the TeO2–MoO3–V2O5glass system

التفاصيل البيبلوغرافية
العنوان: Correlation between the concentration of TeO2and the radiation shielding properties in the TeO2–MoO3–V2O5glass system
المؤلفون: Al-Hadeethi, Y., Sayyed, M.I.
المصدر: Nuclear Engineering and Technology; April 2023, Vol. 55 Issue: 4 p1218-1224, 7p
مستخلص: We investigated the radiation shielding competence for TeO2–V2O5–MoO3glasses. The Phy-X software was used to report the radiation shielding parameters for the present glasses. With an increase in TeO2and MoO3content, the samples' linear attenuation coefficient improves. However, at low energies, this change is more apparent. At low energy, the present samples have an effective atomic number (Zeff) that is relatively high (in order of 16.17–24.48 at 0.347 MeV). In addition, the findings demonstrated that the density of the samples is a very critical factor in determining the half value layer (HVL). The minimal HVL for each sample can be found at 0.347 MeV and corresponds to 1.776, 1.519, 1.391, 1.210 and 1.167 cm for Te1 to Te5 respectively. However, the highest HVL of these glasses is recorded at 1.33 MeV, which corresponds to 3.773, 3.365, 3.218, 2.925 and 2.908 cm respectively. The tenth value layer results indicate that the thickness of the specimens needs to be increased in order to shield the photons that have a greater energy. Also, the TVL results demonstrated that the sample with the greatest TeO2and MoO3concentration has a higher capacity to attenuate photons.