العنوان: Comparison of body weight and composition measured by two different dual energy X-ray absorptiometry devices and three acquisition modes in obese women.
المؤلفون: Genton, Laurence, Karsegard, Véronique L., Zawadynski, Sophie, Kyle, Ursula G., Pichard, Claude, Golay, Alain, Hans, Didier B.
المصدر: Clinical Nutrition; Jun2006, Vol. 25 Issue 3, p428-437, 10p
مستخلص: Summary: Background & aims: Weight measured by dual-energy X-ray (DXA) was shown to be increasingly underestimated in subjects over 75kg compared to an electronic scale. This study compares body weight and composition measured by balance beam scale and three DXA acquisition modes in obese subjects. Methods: In 39 obese, body weight was measured by balance beam scale, and body weight and composition by DXA Hologic QDR4500A® in normal (NPM) and high power mode (HPM) (Enhanced v8.26 and v8.26* softwares) and DXA GE-Lunar Prodigy® (v6.5 software). To ensure linearity of body weight and composition measured by the different DXA acquisitions, we also measured 13 women with a body mass index (BMI) of 25–30kg/m2. Results: While QDR4500A HPM overestimates scale weight by about 2kg over the whole BMI spectrum, QDR4500A NPM underestimates scale weight as a weight-dependent response (−1.7±1.8kg overall, −4.1±1.6kg in morbidly obese women). These results suggest switching from one mode to the other at a specific threshold, i.e. in our study a weight of 90kg or a BMI of 34kg/m2. Prodigy gives weight about similar to scale (+0.5±0.8kg). Both Hologic acquisition modes underestimate fat mass but overestimate lean body mass compared to Prodigy. Conclusions: The QDR4500A NPM is inappropriate in women over 90kg. Unfortunately, the QDR4500A HPM overestimates body weight in the range of 90–150kg. The difference between scale and Prodigy weight remains stable throughout weight ranges. To better assess their accuracies in terms of body composition, QDR4500A NPM, HPM and Prodigy should be tested against phantoms or in vivo multi-compartment models. [Copyright &y& Elsevier]
Copyright of Clinical Nutrition is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Supplemental Index
الوصف
تدمد:02615614
DOI:10.1016/j.clnu.2005.11.002