Extraction of high-frequency SSVEP for BCI control using iterative filtering based empirical mode decomposition.

التفاصيل البيبلوغرافية
العنوان: Extraction of high-frequency SSVEP for BCI control using iterative filtering based empirical mode decomposition.
المؤلفون: Hsu, Chuan-Chih, Yeh, Chia-Lung, Lee, Wai-Keung, Hsu, Hao-Teng, Shyu, Kuo-Kai, Li, Lieber Po-Hung, Wu, Tien-Yu, Lee, Po-Lei
المصدر: Biomedical Signal Processing & Control; Aug2020, Vol. 61, pN.PAG-N.PAG, 1p
مصطلحات موضوعية: HILBERT-Huang transform, VISUAL evoked potentials, IMPEDANCE matching, COMPUTER interfaces, VISUAL perception, COMPUTER engineering
مستخلص: • The effectiveness of using IF-EMD in extracting high-frequency SSVEP has been demonstrated. • The superiority of IF-EMD in avoidance of mode mixing was testified. • A real-time BCI cursor system using SSVEP higher than 40 Hz was established. • The feasibility of extracting high-frequency SSVEP using dry EEG electrode with an impedance matching circuit was confirmed. Steady-state visual evoked potential (SSVEP) has been regarded as an efficient way to design a brain computer interface (BCI). Most SSVEP-based BCIs utilize visual stimuli with flashing frequencies lower than 30 Hz, owing to their better signal-to-noise ratio (SNR). However, the practical applications of low-frequency SSVEP-based BCI are limited, because low-frequency SSVEP usually incur uncomfortable visual experience and the risk of photosensitive epilepsy. In contrast, SSVEP-based BCIs using higher stimulation frequencies (>40 Hz) can induce flicker fusion effect for better visualization. In this study, we studied the feasibility of using iterative filtering - empirical mode decomposition (IF-EMD) to implement a BCI cursor system. EEG signals were recorded from dry EEG electrodes with impedance matching circuits. Three stimulation frequencies, designed at 47, 50, and 53 Hz, were chosen to induce high-frequency SSVEPs, in order to control the leftward, forward and rightward movements of the BCI cursor. Ten subjects were recruited, and each subject was requested to complete a control experiment and an application experiment. In the control experiment, subjects were requested to gaze at each flickering target for thirty seconds. In the application experiment, subjects were instructed to move a cursor to reach three targets on a PC screen. The mean accuracy (Acc), command transfer interval (CTI), and information transfer rate (ITR) in the control experiment were 90.7 ± 2.9%, 1.14 ± 0.07 s, and 54.94 ± 5.41 bits/min, respectively. In the application experiment, the mean execution time and CTI were 30.0 ± 4.69 s and 1.50 ± 0.31 s, respectively. [ABSTRACT FROM AUTHOR]
Copyright of Biomedical Signal Processing & Control is the property of Elsevier B.V. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Supplemental Index
الوصف
تدمد:17468094
DOI:10.1016/j.bspc.2020.102022