مستخلص: Background: Appropriate balancing of the patellofemoral joint (PFJ) using a lateral release can help to prevent patellar instability in total knee arthroplasty (TKA). Contemporary total knee implant designs are characterized by enhanced trochlear geometry more similar to native knee anatomy to minimize instability and reduce utilization of a lateral release.Methods: We retrospectively reviewed consecutive TKA cases from a single senior surgeon's practice with 3 successive total knee designs: the Press-Fit Condylar (PFC), the Sigma, and the ATTUNE (DePuy, Warsaw, IN). We evaluated the use of lateral release with each implant type to determine if design changes have improved patellar stability, reducing the need for lateral release. We used multivariate analysis to determine the association between implant type and lateral release, adjusting for age, sex, preoperative alignment, and bearing type.Results: We evaluated 1991 records of primary TKAs performed from 1980-2015. As compared with the ATTUNE, the adjusted odds of lateral release were greater for patients receiving PFC implants (Odds ratio [OR] 6.35, 95% confidence interval [CI] 3.85,10.49) and Sigma implants (OR 2.02, 95% CI 1.26, 3.23). In addition, fixed bearing implants were associated with greater adjusted odds of lateral release (OR 1.80, 95% CI 1.24, 2.62).Conclusion: We found that older knee implants were associated with higher use of lateral release, with successive designs the need for lateral release to balance the PFJ decreased. Continued design improvements to match the native knee anatomy may further improve the stability of the PFJ in future designs. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Arthroplasty is the property of Churchill Livingstone, Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Supplemental Index
الوصف
تدمد:08835403
DOI:10.1016/j.arth.2016.11.050