Are intracranial pressure wave amplitudes measurable through lumbar puncture?

التفاصيل البيبلوغرافية
العنوان: Are intracranial pressure wave amplitudes measurable through lumbar puncture?
المؤلفون: Behrens, A., Lenfeldt, N., Qvarlander, S., Koskinen, L.‐O., Malm, J., Eklund, A.
المصدر: Acta Neurologica Scandinavica; Apr2013, Vol. 127 Issue 4, p233-241, 9p, 1 Chart, 3 Graphs
مصطلحات موضوعية: LUMBAR puncture, INTRACRANIAL pressure, HYDROCEPHALUS, CEREBROSPINAL fluid pressure, INFUSION therapy, PULSE (Heart beat), BODY fluid pressure, PATIENTS
مستخلص: Objective The aim of this study was to investigate whether pulsations measured in the brain correspond to those measured in lumbar space, and subsequently whether lumbar punctures could replace invasive recordings. Methods In ten patients with normal pressure hydrocephalus, simultaneous recordings of the intracranial pressure ( ICP; intraparenchymal) and lumbar pressure ( LP; cerebrospinal fluid pressure) were performed. During registration, pressure was altered between resting pressure and 45 mmHg using an infusion test. Data were analyzed regarding pulsations (i.e., amplitudes). Also, the pressure sensors were compared in a bench test. Results The correlation between intracranial and lumbar amplitudes was 0.98. At resting pressure, and moderately elevated ICP, intracranial pulse amplitudes exceeded that of lumbar space with about 0.9 mmHg. At the highest ICP, the difference changed to −0.2 mmHg. The bench test showed that the agreement of sensor readings was good at resting pressure, but reduced at higher amplitudes. Conclusions Compared to intracranial registrations, amplitudes measured through lumbar puncture were slightly attenuated. The bench test showed that differences were not attributable to dissimilarities of the sensor systems. A lumbar pressure amplitude measurement is an alternative to ICP recording, but the thresholds for what should be interpreted as elevated amplitudes need to be adjusted. [ABSTRACT FROM AUTHOR]
Copyright of Acta Neurologica Scandinavica is the property of Hindawi Limited and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00016314
DOI:10.1111/j.1600-0404.2012.01701.x