دورية أكاديمية

The reliability, variability and minimal detectable change of multiplanar isometric trunk strength testing using a fixed digital dynamometer.

التفاصيل البيبلوغرافية
العنوان: The reliability, variability and minimal detectable change of multiplanar isometric trunk strength testing using a fixed digital dynamometer.
المؤلفون: Bucke, Jonathan, Mattiussi, Adam, May, Karen, Shaw, Joseph
المصدر: Journal of Sports Sciences; May2024, Vol. 42 Issue 9, p840-846, 7p
مصطلحات موضوعية: TORSO physiology, BIOMECHANICS, RESEARCH evaluation, STATISTICAL sampling, DESCRIPTIVE statistics, MUSCLE strength, STATISTICAL reliability, EXERCISE tests, ATHLETIC ability, DATA analysis software, MUSCLE contraction, RANGE of motion of joints
مستخلص: Trunk strength plays a vital role in athletic performance, rehabilitation and general health, however, current assessment methods are expensive, non-portable or unreliable. This study aimed to investigate the within- and between-session reliability, variability, standard error of measurement and minimal detectable change (MDC) of trunk strength in the sagittal (flexion and extension) and frontal planes (left and right lateral flexion) using a fixed digital dynamometer. Eighteen participants (ten men and eight women) attended two sessions separated by 7 days. Participants were fitted with a trunk harness which was secured to an immovable base via a digital dynamometer. Three maximal voluntary isometric contractions were completed across four positions (prone, supine, left-side recumbent and right-side recumbent, respectively) on a glute-hamstring raise machine. All positions demonstrated excellent reliability and low variability within session (ICC: 0.95–0.98; CV: 5–7%) and between sessions (ICC: 0.98–0.99; CV: 4–6%), across all positions. The between-session MDC ranged from 8% (prone) to 13% (right-side recumbent), translating to absolute values between 2.9 and 3.2 kg across all positions. Maximal isometric force testing using a fixed digital dynamometer provides reliable measurements of multiplanar trunk strength, providing a practical method for use in clinical practice. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Sports Sciences is the property of Taylor & Francis Ltd and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:02640414
DOI:10.1080/02640414.2024.2368785