دورية أكاديمية

A liquid chromatography-mass spectrometry method for the enantioselective multiresidue determination of nine chiral agrochemicals in urine using an enrichment procedure based on graphitized carbon black.

التفاصيل البيبلوغرافية
العنوان: A liquid chromatography-mass spectrometry method for the enantioselective multiresidue determination of nine chiral agrochemicals in urine using an enrichment procedure based on graphitized carbon black.
المؤلفون: Lucci, Elena, Antonelli, Lorenzo, Gherardi, Monica, Fanali, Chiara, Fanali, Salvatore, Scipioni, Anita, Lupattelli, Paolo, Gentili, Alessandra, Chankvetadze, Bezhan
المصدر: Analytical & Bioanalytical Chemistry; Feb2024, Vol. 416 Issue 5, p1127-1137, 11p
مصطلحات موضوعية: LIQUID chromatography-mass spectrometry, CHIRAL stationary phases, CARBON-black, POISONS, AGRICULTURAL chemicals, NON-target organisms
الشركة/الكيان: UNITED States. Food & Drug Administration
مستخلص: Many agrochemicals are chiral molecules, and most of them are marketed as racemates or diastereomeric mixtures. Stereoisomers that are not the active enantiomer have little or no pesticidal activity and can exert serious toxic effects towards non-target organisms. Thus, investigating the possible exposure to different isomers of chiral pesticides is an urgent need. The present work was aimed at developing a new enantioselective high-performance liquid chromatography-mass spectrometry method for the simultaneous determination of nine chiral pesticides in urine. Two solid-phase extraction (SPE) procedures, based on different carbon-based sorbents (graphitized carbon black (GCB) and buckypaper (BP)), were developed and compared. By using GCB, all analytes were recovered with yields ranging from 60 to 97%, while BP allowed recoveries greater than 54% for all pesticides except those with acid characteristics. Baseline separation was achieved for the enantiomers of all target agrochemicals on a Lux Cellulose-2 column within 24 min under reversed-phase mode. The developed method was then validated according to the FDA guidelines for bioanalytical methods. Besides recovery, the other evaluated parameters were precision (7–15%), limits of detection (0.26–2.21 µg/L), lower limits of quantitation (0.43–3.68 µg/L), linear dynamic range, and sensitivity. Finally, the validated method was applied to verify the occurrence of the pesticide enantiomers in urine samples from occupationally exposed workers. [ABSTRACT FROM AUTHOR]
Copyright of Analytical & Bioanalytical Chemistry is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:16182642
DOI:10.1007/s00216-023-05098-4