Cross-sectional audit assessing the quality of dried bloodspot specimens received by UK metabolic biochemistry laboratories for the biochemical monitoring of individuals with Phenylketonuria.

التفاصيل البيبلوغرافية
العنوان: Cross-sectional audit assessing the quality of dried bloodspot specimens received by UK metabolic biochemistry laboratories for the biochemical monitoring of individuals with Phenylketonuria.
المؤلفون: Hogg, Sarah L, Carling, Rachel S, Cantley, Nathan WP, Hamilton, Gillian, Goddard, Philippa, Aitkenhead, Helen, Barski, Robert, Collingwood, Catherine, Moat, Stuart J, Kemp, Helena J
المصدر: Annals of Clinical Biochemistry; May2023, Vol. 60 Issue 3, p208-211, 4p
مصطلحات موضوعية: PHENYLKETONURIA, BLOOD collection, DRIED blood spot testing, AUDITING, BIOCHEMISTRY, PHENYLALANINE
مصطلحات جغرافية: UNITED Kingdom, ENGLAND
مستخلص: Background: Sapropterin has been approved as a treatment option for individuals with Phenylketonuria in the United Kingdom. Individuals are assessed as responsive to Sapropterin by a ≥30% reduction in Phenylalanine (Phe) concentrations using dried blood spot (DBS) specimens. DBS quality is critical for accurate and precise measurement of Phe. Currently, UK national guidelines for DBS specimen acceptance do not exist for patient-collected DBS specimens. We adopted evidence-based guidelines for specimen acceptance criteria and retrospectively assessed the impact of introducing these guidelines on specimen rejection rates. Methods: Laboratories were invited to audit the quality of DBS specimens routinely received for Phe monitoring using: (1) existing acceptance/rejection criteria and (2) proposed national guidelines. Results: Ten laboratories audited 2111 specimens from 1094 individuals. Using existing local guidelines, the median rejection rate was 4.0% (IQR 1.5–7.2%). This increased to 21.9% (IQR 10.0–33.0%) using the proposed guidelines. Where reason(s) for rejection were provided (n = 299); 211/299 (70.6%) of DBS specimens were too small or multi-spotted. 380 individuals had more than one sample evaluated; 231/380 (60.8%) provided specimens of acceptable quality, 37/380 (9.7%) consistently provided poor-quality DBS specimens. Conclusions: There is significant variability in the quality of patient-collected DBS specimens. If unacceptable specimens are not rejected, imprecise/inaccurate results will be used in clinical decision making. Using annual workload data for England, this equates to 12,410 incorrect results. Individuals and parents/carers should receive ongoing training in blood collection technique to ensure use of evidence-based acceptability criteria does not cause undue distress from increased sample rejection rates. [ABSTRACT FROM AUTHOR]
Copyright of Annals of Clinical Biochemistry is the property of Sage Publications Inc. and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00045632
DOI:10.1177/00045632231156035