دورية أكاديمية

Fluorescence grid analysis for the evaluation of piecemeal surgery in sinonasal inverted papilloma: a proof-of-concept study.

التفاصيل البيبلوغرافية
العنوان: Fluorescence grid analysis for the evaluation of piecemeal surgery in sinonasal inverted papilloma: a proof-of-concept study.
المؤلفون: Vonk, J, Voskuil, FJ, de Wit, JG, Heeman, WT, Nagengast, WB, van Dam, GM, Feijen, RA, Korsten-Meijer, AGW, van der Vegt, B, Witjes, MJH
المصدر: European Journal of Nuclear Medicine & Molecular Imaging; Apr2022, Vol. 49 Issue 5, p1640-1649, 10p, 2 Color Photographs, 2 Diagrams, 1 Chart, 1 Graph
مصطلحات موضوعية: MOLECULAR diagnosis, IMMUNOHISTOCHEMISTRY, PAPILLOMA, PARANASAL sinus cancer, MANN Whitney U Test, DIAGNOSTIC imaging, GENE expression, DESCRIPTIVE statistics, VASCULAR endothelial growth factors, DATA analysis software
مستخلص: Purpose: Local recurrence occurs in ~ 19% of sinonasal inverted papilloma (SNIP) surgeries and is strongly associated with incomplete resection. During surgery, it is technically challenging to visualize and resect all SNIP tissue in this anatomically complex area. Proteins that are overexpressed in SNIP, such as vascular endothelial growth factor (VEGF), may serve as a target for fluorescence molecular imaging to guide surgical removal of SNIP. A proof-of-concept study was performed to investigate if the VEGF-targeted near-infrared fluorescent tracer bevacizumab-800CW specifically localizes in SNIP and whether it could be used as a clinical tool to guide SNIP surgery. Methods: In five patients diagnosed with SNIP, 10 mg of bevacizumab-800CW was intravenously administered 3 days prior to surgery. Fluorescence molecular imaging was performed in vivo during surgery and ex vivo during the processing of the surgical specimen. Fluorescence signals were correlated with final histopathology and VEGF-A immunohistochemistry. We introduced a fluorescence grid analysis to assess the fluorescence signal in individual tissue fragments, due to the nature of the surgical procedure (i.e., piecemeal resection) allowing the detection of small SNIP residues and location of the tracer ex vivo. Results: In all patients, fluorescence signal was detected in vivo during endoscopic SNIP surgery. Using ex vivo fluorescence grid analysis, we were able to correlate bevacizumab-800CW fluorescence of individual tissue fragments with final histopathology. Fluorescence grid analysis showed substantial variability in mean fluorescence intensity (FImean), with SNIP tissue showing a median FImean of 77.54 (IQR 50.47–112.30) compared to 35.99 (IQR 21.48–57.81) in uninvolved tissue (p < 0.0001), although the diagnostic ability was limited with an area under the curve of 0.78. Conclusions: A fluorescence grid analysis could serve as a valid method to evaluate fluorescence molecular imaging in piecemeal surgeries. As such, although substantial differences were observed in fluorescence intensities, VEGF-A may not be the ideal target for SNIP surgery. Trial registration: NCT03925285. [ABSTRACT FROM AUTHOR]
Copyright of European Journal of Nuclear Medicine & Molecular Imaging is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:16197070
DOI:10.1007/s00259-021-05567-x