دورية أكاديمية

Survey of newborn direct antiglobulin testing practice in United States and Canadian transfusion services.

التفاصيل البيبلوغرافية
العنوان: Survey of newborn direct antiglobulin testing practice in United States and Canadian transfusion services.
المؤلفون: Crowe, Elizabeth P., Goel, Ruchika, Andrews, Jennifer, Meyer, Erin K., Wong, Trisha E., Sloan, Steven R., Delaney, Meghan, Lieberman, Lani, Cushing, Melissa M.
المصدر: Transfusion; Apr2021, Vol. 61 Issue 4, p1080-1092, 13p
مصطلحات موضوعية: COOMBS' test, CHILDREN'S hospitals, ERYTHROCYTES, ERYTHROBLASTOSIS fetalis, UMBILICAL cord
مصطلحات جغرافية: UNITED States, CANADA
مستخلص: Background: We hypothesized that variability in practice exists for newborn immunohematology testing due to lack of consensus guidelines. We report the results of a survey assessing that variability at hospitals in the United States and Canada.Study Design and Methods: An AABB Pediatric Subsection working party developed and validated a survey of newborn immunohematology testing practice. The survey was sent electronically to transfusion service leadership at teaching institutions.Results: The response rate was 67% (61/91); 56 surveys meeting inclusion criteria were analyzed. Approximately 90% (50/56) were from birth hospitals and 16.1% (9/56) were from pediatric hospitals. Newborn immunohematology testing is ordered as a panel by 66.0% (33/50) of birth hospitals. ABO group and DAT is mandated before discharge in 14/56 (25.0%) and 13/56 (23.2%), respectively. About 76.8% (43/56) selectively perform a DAT according to blood blank or clinical parameters. The most common DAT practices include anti-IgG only testing by 73.2% (41/56) and use of umbilical cord specimen type by 67.9% (38/56). A positive DAT is a critical value for 26.8% (15/56) and followed with eluate testing when a maternal antibody screen is positive for 48.2% (27/56). In the setting of a non-ABO maternal red cell antibody, 55.4% (31/56), phenotype neonatal red cells when the DAT is positive. Group O RBC are transfused irrespective of the DAT result for 82.1%, (46/56).Conclusion: There is variability in newborn immunohematology testing and transfusion practice and potential overutilization of the DAT. Evidence-based consensus guidelines should be developed to standardize practice and to improve safety. [ABSTRACT FROM AUTHOR]
Copyright of Transfusion is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:00411132
DOI:10.1111/trf.16335