دورية أكاديمية

Aortic Frequency Response Determination via Bioimpedance Plethysmography.

التفاصيل البيبلوغرافية
العنوان: Aortic Frequency Response Determination via Bioimpedance Plethysmography.
المؤلفون: Kusche, Roman1 (AUTHOR) roman.kusche@th-luebeck.de, Lindenberg, Arthur-Vincent2 (AUTHOR), Hauschild, Sebastian2 (AUTHOR), Ryschka, Martin2 (AUTHOR)
المصدر: IEEE Transactions on Biomedical Engineering. Nov2019, Vol. 66 Issue 11, p3238-3246. 9p.
مصطلحات موضوعية: THORACIC aorta, PLETHYSMOGRAPHY, GROIN, ARTERIAL diseases, WAVE analysis, ELECTRIC circuits
مستخلص: Objective: Arterial stiffness is an important marker to predict cardiovascular events. Common measurement techniques to determine the condition of the aorta are limited to the acquisition of the arterial pulse wave at the extremities. The goal of this paper is to enable non-invasive measurements of the aortic pulse wave velocity, instead. An additional aim is to extract further information, related to the conditions of the aorta, from the pulse wave signal instead of only its velocity. Methods: After discussing the problems of common pulse wave analysis procedures, an approach to determine the frequency response of the aorta is presented. Therefore, the aorta is modeled as an electrical equivalent circuit. To determine the specific numeric values of this system, a measurement approach is presented, which is based on non-invasive bioimpedance plethysmography measurements above the aortic arch and at the inguinal region. The conversion of the measurement results to the system parameters is realized by a digital algorithm, which is proposed in this paper as well. To evaluate the approach, a study on three subjects is performed. Results: The measurement results demonstrate that the proposed approach yields realistic frequency responses. For better approximation of the aortic system function, more complex models are recommended to investigate in the future. Since this paper is limited to three subjects without a ground truth, further measurements will be necessary. Significance: The proposed approach could solve the problems of current methods to determine the condition of the aorta. Its application is non-invasive, harmless, and easy to execute. [ABSTRACT FROM AUTHOR]
Copyright of IEEE Transactions on Biomedical Engineering is the property of IEEE and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Business Source Index
الوصف
تدمد:00189294
DOI:10.1109/TBME.2019.2902721