دورية أكاديمية

Computational study for the effects of coil configuration on blood flow characteristics in coil-embolized cerebral aneurysm.

التفاصيل البيبلوغرافية
العنوان: Computational study for the effects of coil configuration on blood flow characteristics in coil-embolized cerebral aneurysm.
المؤلفون: Otani, Tomohiro1, Ii, Satoshi1, Shigematsu, Tomoyoshi2, Fujinaka, Toshiyuki2, Hirata, Masayuki2, Ozaki, Tomohiko2, Wada, Shigeo1 shigeo@me.es.osaka-u.ac.jp
المصدر: Medical & Biological Engineering & Computing. May2017, Vol. 55 Issue 5, p697-710. 14p. 7 Color Photographs, 1 Chart, 3 Graphs.
مصطلحات موضوعية: INTRACRANIAL aneurysms, THERAPEUTIC embolization, ELECTRIC coils, BLOOD flow, SHEAR flow, BIOLOGICAL models, CEREBRAL circulation, PHYSICAL & theoretical chemistry, COMPUTER simulation, HEMODYNAMICS, SURGICAL stents
مستخلص: Coil embolization of cerebral aneurysms with inhomogeneous coil distribution leads to an incomplete occlusion of the aneurysm. However, the effects of this factor on the blood flow characteristics are still not fully understood. This study investigates the effects of coil configuration on the blood flow characteristics in a coil-embolized aneurysm using computational fluid dynamics (CFD) simulation. The blood flow analysis in the aneurysm with coil embolization was performed using a coil deployment (CD) model, in which the coil configuration was constructed using a physics-based simulation of the CD. In the CFD results, total flow momentum and kinetic energy in the aneurysm gradually decayed with increasing coil packing density (PD), regardless of the coil configuration attributed to deployment conditions. However, the total shear rate in the aneurysm was relatively high and the strength of the local shear flow varied based on the differences in coil configuration, even at adequate PDs used in clinical practice (20-25 %). Because the sufficient shear rate reduction is a well-known factor in the blood clot formation occluding the aneurysm inside, the present study gives useful insight into the effects of coil configuration on the treatment efficiency of coil embolization. [ABSTRACT FROM AUTHOR]
Copyright of Medical & Biological Engineering & Computing is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Business Source Index
الوصف
تدمد:01400118
DOI:10.1007/s11517-016-1541-6