دورية أكاديمية

Influences of topical cyclopentolate on anterior chamber parameters with a dual-scheimpflug analyzer in healthy children

التفاصيل البيبلوغرافية
العنوان: Influences of topical cyclopentolate on anterior chamber parameters with a dual-scheimpflug analyzer in healthy children
المؤلفون: Güler, E., Güragaç, F.B., Tenlik, A., Yagci, R., Arslanyilmaz, Z., Balci, M.
بيانات النشر: Slack Incorporated
سنة النشر: 2015
المجموعة: Pamukkale University Repository / Pamukkale Üniversitesi Açık Erişim Arşivi
مصطلحات موضوعية: eye drops, cyclopentolate, mydriatic agent, adolescent, anterior chamber volume, anterior eye chamber, anterior eye chamber angle, anterior eye chamber depth, anterior segment parameter, Article, central corneal thickness, child, clinical article, cornea topographer, drug effect, female, human, male, pupil, Student t test, visual system parameters, anatomy and histology, cornea, devices, normal human, physiology, preschool child, prospective study, topical drug administration, visual system examination
الوصف: Purpose: To evaluate the changes of anterior segment parameters following the topical instillation of cyclopentolate hydrochloride 1% with the Galilei dual-Scheimpflug analyzer (GSA) (Ziemer Ophthalmology Co., Port, Switzerland) in healthy children. Methods: Fifty children (29 boys, 21 girls) were evaluated before and 60 minutes after instillation of three drops of 1% cyclopentolate hydrochloride using the GSA. The measurements before and after cycloplegia, including anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), central corneal thickness (CCT), and pupil size, were evaluated using the paired t test. Results: The mean age of the patients was 10.27 ± 3.32 years (range: 5 to 15 years). Measurements between the two sessions were significantly different for all parameters (P .05), except for CCT (P > .05). Conclusions: The GSA demonstrated a statistically significant increase in ACD, ACV, ACA, and pupil size following the topical application of cyclopentolate hydrochloride 1%. These results should be considered during biometric measurement and refractive surgery planning. © SLACK Incorporated.
نوع الوثيقة: article in journal/newspaper
اللغة: English
تدمد: 0191-3913
العلاقة: Journal of Pediatric Ophthalmology and Strabismus; Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı; https://doi.org/10.3928/01913913-20141111-02Test; https://hdl.handle.net/11499/10497Test; 52; 26; 30; 2-s2.0-84928190734; WOS:000351639500008
DOI: 10.3928/01913913-20141111-02
الإتاحة: https://doi.org/10.3928/01913913-20141111-02Test
https://hdl.handle.net/11499/10497Test
حقوق: none
رقم الانضمام: edsbas.A3C5EFA6
قاعدة البيانات: BASE
الوصف
تدمد:01913913
DOI:10.3928/01913913-20141111-02