رسالة جامعية

Korener arter baypas greft cerrahisinde geleneksel ve mini devre (MECC) vücut dışı dolaşım sistemlerinin serum laktat düzeyine etkisi ; Effect of the conventional and mini cycle (MECC) extracorporeal circulation systems on serum lactate level during coronary artery bypass surgery

التفاصيل البيبلوغرافية
العنوان: Korener arter baypas greft cerrahisinde geleneksel ve mini devre (MECC) vücut dışı dolaşım sistemlerinin serum laktat düzeyine etkisi ; Effect of the conventional and mini cycle (MECC) extracorporeal circulation systems on serum lactate level during coronary artery bypass surgery
المؤلفون: Okyay, Türkan
المساهمون: Türkoğlu, Halil
بيانات النشر: İstanbul Medipol Üniversitesi Sağlık Bilimleri Enstitüsü
سنة النشر: 2019
المجموعة: İstanbul Medipol University Institutional Repository (DSpace@Medipol)
مصطلحات موضوعية: Centrifugal Pompa, Ekstrakorporeal Dolaşım, Kardiyopulmoner Bypass, Koroner Arter Bypass, L-Laktat Dehidrogenaz, Cardiopulmonary Bypass, Centrifugal Pumps, Coronary Artery Bypass, Extracorporeal Circulation, L-Lactate Dehydrogenase
الوصف: Bu çalışmada koroner arter baypas (KABG) ameliyatlarında geleneksel ve mini devre (MECC) vücut dışı dolaşım sistemlerinde serum laktat düzeylerini karşılaştırıp doku perfüzyonuna etkisini değerlendirmeyi amaçladık. Çalışma 2017-2018 yılları arasında Ahi Evren Göğüs Kalp ve Damar Cerrahisi Hastanesinde izole KABG ameliyatı olan 40 hasta üzerinde yapılmıştır. Çalışma gubumuz ejeksiyon fraksiyonu (EF) % 40 ve üzerinde olan, revize edilmemiş hastalardan oluşmaktadır. Ardışık randomize hastalar, Grup 1 (n: 20) geleneksel grup ve Grup 2 (n: 20) MECC grubu olmak üzere iki gruba ayrıldı. Bu çalışma retrospektif kesitsel bir çalışmadır. Veriler, hazırlanan hasta veri takip formu ile toplanmıştır. Veriler incelendiğinde ACT düzeyi grup 1'de 440,80 ± 33,44 saniye ve grup 2'de 286,35 ± 38,22 saniye (p<0,001) bulunmuştur. Drenaj grup 1'de 800 ml (min: 300 - max: 2000) iken grup 2'de 450 ml (min: 300 - max: 1000) (p<0,001) istatiksel olarak anlamlıdır. Gruplar arasında karşılaştırmada MECC sistemde post-op. ve 3. gün serum laktat düzeyi daha düşük seviyede tespit edilmiştir. MECC sisteminin vücut dışı dolaşımda kullanılmasına bağlı azalan serum laktat düzeyi doku perfüzyonunda geleneksel sistemden daha iyi olduğuna işaret etmektedir. MECC, KABG ameliyatlarında doku perfüzyonu için güvenli bir perfüzyon tekniğidir ve riskli hastalarda alternatif olarak kullanabilecek bir yöntemdir. ; In this study, we aimed to compare serum lactate levels in conventional and mini-circuit (MECC) extracorporeal circulatory systems in coronary artery bypass graft (CABG) operations and to evaluate the effect on tissue perfusion. The study was performed on 40 patients with isolated CABG surgery in Ahi Evren Thoracic and Cardiovascular Surgery Hospital between 2017-2018. Our study group consisted of non-revised patients with ejection fraction (EF) % 40 and above. The consecutive randomized patients were divided into two groups as Group 1 (n: 20) conventional group and Group 2 (n: 20) MECC group. This study is a retrospective cross-sectional ...
نوع الوثيقة: master thesis
وصف الملف: application/pdf
اللغة: Turkish
العلاقة: Tez; Okyay, T. (2019). Korener arter baypas greft cerrahisinde geleneksel ve mini devre (MECC) vücut dışı dolaşım sistemlerinin serum laktat düzeyine etkisi. (Yayınlanmamış yüksek lisans tezi). İstanbul Medipol Üniversitesi Sağlık Bilimleri Enstitüsü, İstanbul.; https://hdl.handle.net/20.500.12511/7558Test
الإتاحة: https://doi.org/20.500.12511/7558Test
https://hdl.handle.net/20.500.12511/7558Test
حقوق: info:eu-repo/semantics/openAccess
رقم الانضمام: edsbas.89104560
قاعدة البيانات: BASE
ResultId 1
Header edsbas
BASE
edsbas.89104560
826
3
Dissertation/ Thesis
dissertation
825.687927246094
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsbas&AN=edsbas.89104560&custid=s6537998&authtype=sso
FullText Array ( [Availability] => 0 )
Array ( [0] => Array ( [Url] => https://doi.org/20.500.12511/7558# [Name] => EDS - BASE [Category] => fullText [Text] => View record in BASE [MouseOverText] => View record in BASE ) )
Items Array ( [Name] => Title [Label] => Title [Group] => Ti [Data] => Korener arter baypas greft cerrahisinde geleneksel ve mini devre (MECC) v&#252;cut dışı dolaşım sistemlerinin serum laktat d&#252;zeyine etkisi ; Effect of the conventional and mini cycle (MECC) extracorporeal circulation systems on serum lactate level during coronary artery bypass surgery )
Array ( [Name] => Author [Label] => Authors [Group] => Au [Data] => &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Okyay%2C+T&#252;rkan%22&quot;&gt;Okyay, T&#252;rkan&lt;/searchLink&gt; )
Array ( [Name] => Author [Label] => Contributors [Group] => Au [Data] => T&#252;rkoğlu, Halil )
Array ( [Name] => Publisher [Label] => Publisher Information [Group] => PubInfo [Data] => İstanbul Medipol &#220;niversitesi Sağlık Bilimleri Enstit&#252;s&#252; )
Array ( [Name] => DatePubCY [Label] => Publication Year [Group] => Date [Data] => 2019 )
Array ( [Name] => Subset [Label] => Collection [Group] => HoldingsInfo [Data] => İstanbul Medipol University Institutional Repository (DSpace@Medipol) )
Array ( [Name] => Subject [Label] => Subject Terms [Group] => Su [Data] => &lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Centrifugal+Pompa%22&quot;&gt;Centrifugal Pompa&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Ekstrakorporeal+Dolaşım%22&quot;&gt;Ekstrakorporeal Dolaşım&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Kardiyopulmoner+Bypass%22&quot;&gt;Kardiyopulmoner Bypass&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Koroner+Arter+Bypass%22&quot;&gt;Koroner Arter Bypass&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22L-Laktat+Dehidrogenaz%22&quot;&gt;L-Laktat Dehidrogenaz&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Cardiopulmonary+Bypass%22&quot;&gt;Cardiopulmonary Bypass&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Centrifugal+Pumps%22&quot;&gt;Centrifugal Pumps&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Coronary+Artery+Bypass%22&quot;&gt;Coronary Artery Bypass&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22Extracorporeal+Circulation%22&quot;&gt;Extracorporeal Circulation&lt;/searchLink&gt;&lt;br /&gt;&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22L-Lactate+Dehydrogenase%22&quot;&gt;L-Lactate Dehydrogenase&lt;/searchLink&gt; )
Array ( [Name] => Abstract [Label] => Description [Group] => Ab [Data] => Bu &#231;alışmada koroner arter baypas (KABG) ameliyatlarında geleneksel ve mini devre (MECC) v&#252;cut dışı dolaşım sistemlerinde serum laktat d&#252;zeylerini karşılaştırıp doku perf&#252;zyonuna etkisini değerlendirmeyi ama&#231;ladık. &#199;alışma 2017-2018 yılları arasında Ahi Evren G&#246;ğ&#252;s Kalp ve Damar Cerrahisi Hastanesinde izole KABG ameliyatı olan 40 hasta &#252;zerinde yapılmıştır. &#199;alışma gubumuz ejeksiyon fraksiyonu (EF) % 40 ve &#252;zerinde olan, revize edilmemiş hastalardan oluşmaktadır. Ardışık randomize hastalar, Grup 1 (n: 20) geleneksel grup ve Grup 2 (n: 20) MECC grubu olmak &#252;zere iki gruba ayrıldı. Bu &#231;alışma retrospektif kesitsel bir &#231;alışmadır. Veriler, hazırlanan hasta veri takip formu ile toplanmıştır. Veriler incelendiğinde ACT d&#252;zeyi grup 1&#39;de 440,80 &#177; 33,44 saniye ve grup 2&#39;de 286,35 &#177; 38,22 saniye (p&lt;0,001) bulunmuştur. Drenaj grup 1&#39;de 800 ml (min: 300 - max: 2000) iken grup 2&#39;de 450 ml (min: 300 - max: 1000) (p&lt;0,001) istatiksel olarak anlamlıdır. Gruplar arasında karşılaştırmada MECC sistemde post-op. ve 3. g&#252;n serum laktat d&#252;zeyi daha d&#252;ş&#252;k seviyede tespit edilmiştir. MECC sisteminin v&#252;cut dışı dolaşımda kullanılmasına bağlı azalan serum laktat d&#252;zeyi doku perf&#252;zyonunda geleneksel sistemden daha iyi olduğuna işaret etmektedir. MECC, KABG ameliyatlarında doku perf&#252;zyonu i&#231;in g&#252;venli bir perf&#252;zyon tekniğidir ve riskli hastalarda alternatif olarak kullanabilecek bir y&#246;ntemdir. ; In this study, we aimed to compare serum lactate levels in conventional and mini-circuit (MECC) extracorporeal circulatory systems in coronary artery bypass graft (CABG) operations and to evaluate the effect on tissue perfusion. The study was performed on 40 patients with isolated CABG surgery in Ahi Evren Thoracic and Cardiovascular Surgery Hospital between 2017-2018. Our study group consisted of non-revised patients with ejection fraction (EF) % 40 and above. The consecutive randomized patients were divided into two groups as Group 1 (n: 20) conventional group and Group 2 (n: 20) MECC group. This study is a retrospective cross-sectional ... )
Array ( [Name] => TypeDocument [Label] => Document Type [Group] => TypDoc [Data] => master thesis )
Array ( [Name] => Format [Label] => File Description [Group] => SrcInfo [Data] => application/pdf )
Array ( [Name] => Language [Label] => Language [Group] => Lang [Data] => Turkish )
Array ( [Name] => NoteTitleSource [Label] => Relation [Group] => SrcInfo [Data] => Tez; Okyay, T. (2019). Korener arter baypas greft cerrahisinde geleneksel ve mini devre (MECC) v&#252;cut dışı dolaşım sistemlerinin serum laktat d&#252;zeyine etkisi. (Yayınlanmamış y&#252;ksek lisans tezi). İstanbul Medipol &#220;niversitesi Sağlık Bilimleri Enstit&#252;s&#252;, İstanbul.; https://hdl.handle.net/20.500.12511/7558 )
Array ( [Name] => URL [Label] => Availability [Group] => URL [Data] => https://doi.org/20.500.12511/7558&lt;br /&gt;https://hdl.handle.net/20.500.12511/7558 )
Array ( [Name] => Copyright [Label] => Rights [Group] => Cpyrght [Data] => info:eu-repo/semantics/openAccess )
Array ( [Name] => AN [Label] => Accession Number [Group] => ID [Data] => edsbas.89104560 )
RecordInfo Array ( [BibEntity] => Array ( [Languages] => Array ( [0] => Array ( [Text] => Turkish ) ) [Subjects] => Array ( [0] => Array ( [SubjectFull] => Centrifugal Pompa [Type] => general ) [1] => Array ( [SubjectFull] => Ekstrakorporeal Dolaşım [Type] => general ) [2] => Array ( [SubjectFull] => Kardiyopulmoner Bypass [Type] => general ) [3] => Array ( [SubjectFull] => Koroner Arter Bypass [Type] => general ) [4] => Array ( [SubjectFull] => L-Laktat Dehidrogenaz [Type] => general ) [5] => Array ( [SubjectFull] => Cardiopulmonary Bypass [Type] => general ) [6] => Array ( [SubjectFull] => Centrifugal Pumps [Type] => general ) [7] => Array ( [SubjectFull] => Coronary Artery Bypass [Type] => general ) [8] => Array ( [SubjectFull] => Extracorporeal Circulation [Type] => general ) [9] => Array ( [SubjectFull] => L-Lactate Dehydrogenase [Type] => general ) ) [Titles] => Array ( [0] => Array ( [TitleFull] => Korener arter baypas greft cerrahisinde geleneksel ve mini devre (MECC) vücut dışı dolaşım sistemlerinin serum laktat düzeyine etkisi ; Effect of the conventional and mini cycle (MECC) extracorporeal circulation systems on serum lactate level during coronary artery bypass surgery [Type] => main ) ) ) [BibRelationships] => Array ( [HasContributorRelationships] => Array ( [0] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Okyay, Türkan ) ) ) [1] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Türkoğlu, Halil ) ) ) ) [IsPartOfRelationships] => Array ( [0] => Array ( [BibEntity] => Array ( [Dates] => Array ( [0] => Array ( [D] => 01 [M] => 01 [Type] => published [Y] => 2019 ) ) [Identifiers] => Array ( [0] => Array ( [Type] => issn-locals [Value] => edsbas ) [1] => Array ( [Type] => issn-locals [Value] => edsbas.oa ) ) ) ) ) ) )
IllustrationInfo