A fully integrated electrochemical bioMEMS fabrication process for cytokine detection: application for heart failure

التفاصيل البيبلوغرافية
العنوان: A fully integrated electrochemical bioMEMS fabrication process for cytokine detection: application for heart failure
المؤلفون: Baraket, Abdoullatif, Lee, Michael, Zine, Nadia, Sigaud, Monique, Zabala, Miguel, Bausells, Joan, Errachid, Abdelhamid
المساهمون: ISA-Micro & Nanobiotechnologies, Institut des Sciences Analytiques (ISA), Université Claude Bernard Lyon 1 (UCBL), Université de Lyon-Université de Lyon-Institut de Chimie - CNRS Chimie (INC-CNRS)-Centre National de la Recherche Scientifique (CNRS)-Université Claude Bernard Lyon 1 (UCBL), Université de Lyon-Université de Lyon-Institut de Chimie - CNRS Chimie (INC-CNRS)-Centre National de la Recherche Scientifique (CNRS), Instituto de Microelectrònica de Barcelona (IMB-CNM), Consejo Superior de Investigaciones Cientificas España = Spanish National Research Council Spain (CSIC)-Centro Nacional de Microelectronica Spain (CNM)
المصدر: EUROSENSORS 2014, the 28th European Conference on Solid-State Transducers ; https://hal.science/hal-01363713Test ; EUROSENSORS 2014, the 28th European Conference on Solid-State Transducers, Sep 2014, Brescia, Italy. pp.377-379, ⟨10.1016/j.proeng.2014.11.737⟩
بيانات النشر: HAL CCSD
سنة النشر: 2014
المجموعة: HAL Lyon 1 (University Claude Bernard Lyon 1)
مصطلحات موضوعية: BioMEMS, heart failure, impedance spectroscopy, cytokine biomarkers, microtechnology, [CHIM.ANAL]Chemical Sciences/Analytical chemistry
جغرافية الموضوع: Brescia, Italy
الوصف: International audience ; In this present study, a fully integrated BioMEMS was developed using silicon technology to simultaneously detect varying cytokine biomarkers: interleukin-1 (IL-1), interleukin-10 (IL-10), and interleukin-6 (IL-6) using eight gold working microelectrodes (WE). The biomarkers are one of many antigens that are secreted in acute stages of inflammation after left ventricle assisted device (LVAD) implantation for patients suffering from heart failure (HF). The monoclonal antibodies (mAb): anti-human IL-1, IL-10, and IL-6 were immobilized onto gold microelectrodes through functionalization with carboxyl diazonium, respectively. Cyclic voltammetry (CV) was applied during the microelectrode functionalization process to characterize the gold microelectrode surface properties, while electrochemical impedance spectroscopy (EIS) was used to characterize the modified gold microelectrodes. The BioMEMS was highly sensitive towards the three cytokines in a range of 1 pg/mL to 15 pg/mL, which is the window where acute inflammations were observed.
نوع الوثيقة: conference object
اللغة: English
العلاقة: hal-01363713; https://hal.science/hal-01363713Test
DOI: 10.1016/j.proeng.2014.11.737
الإتاحة: https://doi.org/10.1016/j.proeng.2014.11.737Test
https://hal.science/hal-01363713Test
رقم الانضمام: edsbas.7A0C987
قاعدة البيانات: BASE
ResultId 1
Header edsbas
BASE
edsbas.7A0C987
800
3
Conference
conference
799.518249511719
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsbas&AN=edsbas.7A0C987&custid=s6537998&authtype=sso
FullText Array ( [Availability] => 0 )
Array ( [0] => Array ( [Url] => https://doi.org/10.1016/j.proeng.2014.11.737# [Name] => EDS - BASE [Category] => fullText [Text] => View record in BASE [MouseOverText] => View record in BASE ) )
Items Array ( [Name] => Title [Label] => Title [Group] => Ti [Data] => A fully integrated electrochemical bioMEMS fabrication process for cytokine detection: application for heart failure )
Array ( [Name] => Author [Label] => Authors [Group] => Au [Data] => <searchLink fieldCode="AR" term="%22Baraket%2C+Abdoullatif%22">Baraket, Abdoullatif</searchLink><br /><searchLink fieldCode="AR" term="%22Lee%2C+Michael%22">Lee, Michael</searchLink><br /><searchLink fieldCode="AR" term="%22Zine%2C+Nadia%22">Zine, Nadia</searchLink><br /><searchLink fieldCode="AR" term="%22Sigaud%2C+Monique%22">Sigaud, Monique</searchLink><br /><searchLink fieldCode="AR" term="%22Zabala%2C+Miguel%22">Zabala, Miguel</searchLink><br /><searchLink fieldCode="AR" term="%22Bausells%2C+Joan%22">Bausells, Joan</searchLink><br /><searchLink fieldCode="AR" term="%22Errachid%2C+Abdelhamid%22">Errachid, Abdelhamid</searchLink> )
Array ( [Name] => Author [Label] => Contributors [Group] => Au [Data] => ISA-Micro & Nanobiotechnologies<br />Institut des Sciences Analytiques (ISA)<br />Université Claude Bernard Lyon 1 (UCBL)<br />Université de Lyon-Université de Lyon-Institut de Chimie - CNRS Chimie (INC-CNRS)-Centre National de la Recherche Scientifique (CNRS)-Université Claude Bernard Lyon 1 (UCBL)<br />Université de Lyon-Université de Lyon-Institut de Chimie - CNRS Chimie (INC-CNRS)-Centre National de la Recherche Scientifique (CNRS)<br />Instituto de Microelectrònica de Barcelona (IMB-CNM)<br />Consejo Superior de Investigaciones Cientificas España = Spanish National Research Council Spain (CSIC)-Centro Nacional de Microelectronica Spain (CNM) )
Array ( [Name] => TitleSource [Label] => Source [Group] => Src [Data] => EUROSENSORS 2014, the 28th European Conference on Solid-State Transducers ; https://hal.science/hal-01363713 ; EUROSENSORS 2014, the 28th European Conference on Solid-State Transducers, Sep 2014, Brescia, Italy. pp.377-379, ⟨10.1016/j.proeng.2014.11.737⟩ )
Array ( [Name] => Publisher [Label] => Publisher Information [Group] => PubInfo [Data] => HAL CCSD )
Array ( [Name] => DatePubCY [Label] => Publication Year [Group] => Date [Data] => 2014 )
Array ( [Name] => Subset [Label] => Collection [Group] => HoldingsInfo [Data] => HAL Lyon 1 (University Claude Bernard Lyon 1) )
Array ( [Name] => Subject [Label] => Subject Terms [Group] => Su [Data] => <searchLink fieldCode="DE" term="%22BioMEMS%22">BioMEMS</searchLink><br /><searchLink fieldCode="DE" term="%22heart+failure%22">heart failure</searchLink><br /><searchLink fieldCode="DE" term="%22impedance+spectroscopy%22">impedance spectroscopy</searchLink><br /><searchLink fieldCode="DE" term="%22cytokine+biomarkers%22">cytokine biomarkers</searchLink><br /><searchLink fieldCode="DE" term="%22microtechnology%22">microtechnology</searchLink><br /><searchLink fieldCode="DE" term="%22[CHIM%2EANAL]Chemical+Sciences%2FAnalytical+chemistry%22">[CHIM.ANAL]Chemical Sciences/Analytical chemistry</searchLink> )
Array ( [Name] => Subject [Label] => Subject Geographic [Group] => Su [Data] => <searchLink fieldCode="DE" term="%22Brescia%22">Brescia</searchLink><br /><searchLink fieldCode="DE" term="%22Italy%22">Italy</searchLink> )
Array ( [Name] => Abstract [Label] => Description [Group] => Ab [Data] => International audience ; In this present study, a fully integrated BioMEMS was developed using silicon technology to simultaneously detect varying cytokine biomarkers: interleukin-1 (IL-1), interleukin-10 (IL-10), and interleukin-6 (IL-6) using eight gold working microelectrodes (WE). The biomarkers are one of many antigens that are secreted in acute stages of inflammation after left ventricle assisted device (LVAD) implantation for patients suffering from heart failure (HF). The monoclonal antibodies (mAb): anti-human IL-1, IL-10, and IL-6 were immobilized onto gold microelectrodes through functionalization with carboxyl diazonium, respectively. Cyclic voltammetry (CV) was applied during the microelectrode functionalization process to characterize the gold microelectrode surface properties, while electrochemical impedance spectroscopy (EIS) was used to characterize the modified gold microelectrodes. The BioMEMS was highly sensitive towards the three cytokines in a range of 1 pg/mL to 15 pg/mL, which is the window where acute inflammations were observed. )
Array ( [Name] => TypeDocument [Label] => Document Type [Group] => TypDoc [Data] => conference object )
Array ( [Name] => Language [Label] => Language [Group] => Lang [Data] => English )
Array ( [Name] => NoteTitleSource [Label] => Relation [Group] => SrcInfo [Data] => hal-01363713; https://hal.science/hal-01363713 )
Array ( [Name] => DOI [Label] => DOI [Group] => ID [Data] => 10.1016/j.proeng.2014.11.737 )
Array ( [Name] => URL [Label] => Availability [Group] => URL [Data] => https://doi.org/10.1016/j.proeng.2014.11.737<br />https://hal.science/hal-01363713 )
Array ( [Name] => AN [Label] => Accession Number [Group] => ID [Data] => edsbas.7A0C987 )
RecordInfo Array ( [BibEntity] => Array ( [Identifiers] => Array ( [0] => Array ( [Type] => doi [Value] => 10.1016/j.proeng.2014.11.737 ) ) [Languages] => Array ( [0] => Array ( [Text] => English ) ) [Subjects] => Array ( [0] => Array ( [SubjectFull] => Brescia [Type] => general ) [1] => Array ( [SubjectFull] => Italy [Type] => general ) [2] => Array ( [SubjectFull] => BioMEMS [Type] => general ) [3] => Array ( [SubjectFull] => heart failure [Type] => general ) [4] => Array ( [SubjectFull] => impedance spectroscopy [Type] => general ) [5] => Array ( [SubjectFull] => cytokine biomarkers [Type] => general ) [6] => Array ( [SubjectFull] => microtechnology [Type] => general ) [7] => Array ( [SubjectFull] => [CHIM.ANAL]Chemical Sciences/Analytical chemistry [Type] => general ) ) [Titles] => Array ( [0] => Array ( [TitleFull] => A fully integrated electrochemical bioMEMS fabrication process for cytokine detection: application for heart failure [Type] => main ) ) ) [BibRelationships] => Array ( [HasContributorRelationships] => Array ( [0] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Baraket, Abdoullatif ) ) ) [1] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Lee, Michael ) ) ) [2] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Zine, Nadia ) ) ) [3] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Sigaud, Monique ) ) ) [4] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Zabala, Miguel ) ) ) [5] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Bausells, Joan ) ) ) [6] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Errachid, Abdelhamid ) ) ) [7] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => ISA-Micro & Nanobiotechnologies ) ) ) [8] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Institut des Sciences Analytiques (ISA) ) ) ) [9] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Université Claude Bernard Lyon 1 (UCBL) ) ) ) [10] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Université de Lyon-Université de Lyon-Institut de Chimie - CNRS Chimie (INC-CNRS)-Centre National de la Recherche Scientifique (CNRS)-Université Claude Bernard Lyon 1 (UCBL) ) ) ) [11] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Université de Lyon-Université de Lyon-Institut de Chimie - CNRS Chimie (INC-CNRS)-Centre National de la Recherche Scientifique (CNRS) ) ) ) [12] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Instituto de Microelectrònica de Barcelona (IMB-CNM) ) ) ) [13] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Consejo Superior de Investigaciones Cientificas España = Spanish National Research Council Spain (CSIC)-Centro Nacional de Microelectronica Spain (CNM) ) ) ) ) [IsPartOfRelationships] => Array ( [0] => Array ( [BibEntity] => Array ( [Dates] => Array ( [0] => Array ( [D] => 01 [M] => 01 [Type] => published [Y] => 2014 ) ) [Identifiers] => Array ( [0] => Array ( [Type] => issn-locals [Value] => edsbas ) ) [Titles] => Array ( [0] => Array ( [TitleFull] => EUROSENSORS 2014, the 28th European Conference on Solid-State Transducers ; https://hal.science/hal-01363713 ; EUROSENSORS 2014, the 28th European Conference on Solid-State Transducers, Sep 2014, Brescia, Italy. pp.377-379, ⟨10.1016/j.proeng.2014.11.737⟩ [Type] => main ) ) ) ) ) ) )
IllustrationInfo