دورية أكاديمية

Eccentric exercise increases EMG amplitude and force fluctuations during submaximal contractions of elbow flexor muscles

التفاصيل البيبلوغرافية
العنوان: Eccentric exercise increases EMG amplitude and force fluctuations during submaximal contractions of elbow flexor muscles
المؤلفون: Semmler, John G., Tucker, Kylie J., Allen, Trevor J., Proske, Uwe
بيانات النشر: American Physiological Society
سنة النشر: 2007
المجموعة: The University of Queensland: UQ eSpace
مصطلحات موضوعية: Motor-unit synchronization, skeletal muscle, voluntary activation, concentric exercise, induced injury, maximal force, hand muscle, surface emg, old adults, damage, 1116 Medical Physiology
الوصف: The purpose of this study was to determine the effect of eccentric exercise on the ability to exert steady submaximal forces with muscles that cross the elbow joint. Eight subjects performed two tasks requiring isometric contraction of the right elbow flexors: a maximum voluntary contraction (MVC) and a constant-force task at four submaximal target forces (5, 20, 35, 50% MVC) while electromyography (EMG) was recorded from elbow flexor and extensor muscles. These tasks were performed before, after, and 24 h after a period of eccentric (fatigue and muscle damage) or concentric exercise (fatigue only). MVC force declined after eccentric exercise (45% decline) and remained depressed 24 h later (24%), whereas the reduced force after concentric exercise (22%) fully recovered the following day. EMG amplitude during the submaximal contractions increased in all elbow flexor muscles after eccentric exercise, with the greatest change in the biceps brachii at low forces (3-4 times larger at 5 and 20% MVC) and in the brachialis muscle at moderate forces (2 times larger at 35 and 50% MVC). Eccentric exercise resulted in a twofold increase in coactivation of the triceps brachii muscle during all submaximal contractions. Force fluctuations were larger after eccentric exercise, particularly at low forces (3-4 times larger at 5% MVC, 2 times larger at 50% MVC), with a twofold increase in physiological tremor at 8-12 Hz. These data indicate that eccentric exercise results in impaired motor control and altered neural drive to elbow flexor muscles, particularly at low forces, suggesting altered motor unit activation after eccentric exercise.
نوع الوثيقة: article in journal/newspaper
اللغة: English
تدمد: 8750-7587
العلاقة: orcid:0000-0003-4976-7483
الإتاحة: https://doi.org/10.1152/japplphysiol.01310.2006Test
https://espace.library.uq.edu.au/view/UQ:138030Test
رقم الانضمام: edsbas.2D86FD59
قاعدة البيانات: BASE
ResultId 1
Header edsbas
BASE
edsbas.2D86FD59
767
3
Academic Journal
academicJournal
767.334289550781
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsbas&AN=edsbas.2D86FD59&custid=s6537998&authtype=sso
FullText Array ( [Availability] => 0 )
Array ( [0] => Array ( [Url] => https://doi.org/10.1152/japplphysiol.01310.2006# [Name] => EDS - BASE [Category] => fullText [Text] => View record in BASE [MouseOverText] => View record in BASE ) [1] => Array ( [Url] => https://resolver.ebscohost.com/openurl?custid=s6537998&groupid=main&authtype=ip,guest&sid=EBSCO:edsbas&genre=article&issn=87507587&ISBN=&volume=&issue=&date=20070101&spage=&pages=&title=Eccentric exercise increases EMG amplitude and force fluctuations during submaximal contractions of elbow flexor muscles&atitle=Eccentric%20exercise%20increases%20EMG%20amplitude%20and%20force%20fluctuations%20during%20submaximal%20contractions%20of%20elbow%20flexor%20muscles&id=DOI: [Name] => Full Text Finder (s6537998api) [Category] => fullText [Text] => Full Text Finder [Icon] => https://imageserver.ebscohost.com/branding/images/FTF.gif [MouseOverText] => Full Text Finder ) )
Items Array ( [Name] => Title [Label] => Title [Group] => Ti [Data] => Eccentric exercise increases EMG amplitude and force fluctuations during submaximal contractions of elbow flexor muscles )
Array ( [Name] => Author [Label] => Authors [Group] => Au [Data] => <searchLink fieldCode="AR" term="%22Semmler%2C+John+G%2E%22">Semmler, John G.</searchLink><br /><searchLink fieldCode="AR" term="%22Tucker%2C+Kylie+J%2E%22">Tucker, Kylie J.</searchLink><br /><searchLink fieldCode="AR" term="%22Allen%2C+Trevor+J%2E%22">Allen, Trevor J.</searchLink><br /><searchLink fieldCode="AR" term="%22Proske%2C+Uwe%22">Proske, Uwe</searchLink> )
Array ( [Name] => Publisher [Label] => Publisher Information [Group] => PubInfo [Data] => American Physiological Society )
Array ( [Name] => DatePubCY [Label] => Publication Year [Group] => Date [Data] => 2007 )
Array ( [Name] => Subset [Label] => Collection [Group] => HoldingsInfo [Data] => The University of Queensland: UQ eSpace )
Array ( [Name] => Subject [Label] => Subject Terms [Group] => Su [Data] => <searchLink fieldCode="DE" term="%22Motor-unit+synchronization%22">Motor-unit synchronization</searchLink><br /><searchLink fieldCode="DE" term="%22skeletal+muscle%22">skeletal muscle</searchLink><br /><searchLink fieldCode="DE" term="%22voluntary+activation%22">voluntary activation</searchLink><br /><searchLink fieldCode="DE" term="%22concentric+exercise%22">concentric exercise</searchLink><br /><searchLink fieldCode="DE" term="%22induced+injury%22">induced injury</searchLink><br /><searchLink fieldCode="DE" term="%22maximal+force%22">maximal force</searchLink><br /><searchLink fieldCode="DE" term="%22hand+muscle%22">hand muscle</searchLink><br /><searchLink fieldCode="DE" term="%22surface+emg%22">surface emg</searchLink><br /><searchLink fieldCode="DE" term="%22old+adults%22">old adults</searchLink><br /><searchLink fieldCode="DE" term="%22damage%22">damage</searchLink><br /><searchLink fieldCode="DE" term="%221116+Medical+Physiology%22">1116 Medical Physiology</searchLink> )
Array ( [Name] => Abstract [Label] => Description [Group] => Ab [Data] => The purpose of this study was to determine the effect of eccentric exercise on the ability to exert steady submaximal forces with muscles that cross the elbow joint. Eight subjects performed two tasks requiring isometric contraction of the right elbow flexors: a maximum voluntary contraction (MVC) and a constant-force task at four submaximal target forces (5, 20, 35, 50% MVC) while electromyography (EMG) was recorded from elbow flexor and extensor muscles. These tasks were performed before, after, and 24 h after a period of eccentric (fatigue and muscle damage) or concentric exercise (fatigue only). MVC force declined after eccentric exercise (45% decline) and remained depressed 24 h later (24%), whereas the reduced force after concentric exercise (22%) fully recovered the following day. EMG amplitude during the submaximal contractions increased in all elbow flexor muscles after eccentric exercise, with the greatest change in the biceps brachii at low forces (3-4 times larger at 5 and 20% MVC) and in the brachialis muscle at moderate forces (2 times larger at 35 and 50% MVC). Eccentric exercise resulted in a twofold increase in coactivation of the triceps brachii muscle during all submaximal contractions. Force fluctuations were larger after eccentric exercise, particularly at low forces (3-4 times larger at 5% MVC, 2 times larger at 50% MVC), with a twofold increase in physiological tremor at 8-12 Hz. These data indicate that eccentric exercise results in impaired motor control and altered neural drive to elbow flexor muscles, particularly at low forces, suggesting altered motor unit activation after eccentric exercise. )
Array ( [Name] => TypeDocument [Label] => Document Type [Group] => TypDoc [Data] => article in journal/newspaper )
Array ( [Name] => Language [Label] => Language [Group] => Lang [Data] => English )
Array ( [Name] => ISSN [Label] => ISSN [Group] => ISSN [Data] => 8750-7587 )
Array ( [Name] => NoteTitleSource [Label] => Relation [Group] => SrcInfo [Data] => orcid:0000-0003-4976-7483 )
Array ( [Name] => URL [Label] => Availability [Group] => URL [Data] => https://doi.org/10.1152/japplphysiol.01310.2006<br />https://espace.library.uq.edu.au/view/UQ:138030 )
Array ( [Name] => AN [Label] => Accession Number [Group] => ID [Data] => edsbas.2D86FD59 )
RecordInfo Array ( [BibEntity] => Array ( [Languages] => Array ( [0] => Array ( [Text] => English ) ) [Subjects] => Array ( [0] => Array ( [SubjectFull] => Motor-unit synchronization [Type] => general ) [1] => Array ( [SubjectFull] => skeletal muscle [Type] => general ) [2] => Array ( [SubjectFull] => voluntary activation [Type] => general ) [3] => Array ( [SubjectFull] => concentric exercise [Type] => general ) [4] => Array ( [SubjectFull] => induced injury [Type] => general ) [5] => Array ( [SubjectFull] => maximal force [Type] => general ) [6] => Array ( [SubjectFull] => hand muscle [Type] => general ) [7] => Array ( [SubjectFull] => surface emg [Type] => general ) [8] => Array ( [SubjectFull] => old adults [Type] => general ) [9] => Array ( [SubjectFull] => damage [Type] => general ) [10] => Array ( [SubjectFull] => 1116 Medical Physiology [Type] => general ) ) [Titles] => Array ( [0] => Array ( [TitleFull] => Eccentric exercise increases EMG amplitude and force fluctuations during submaximal contractions of elbow flexor muscles [Type] => main ) ) ) [BibRelationships] => Array ( [HasContributorRelationships] => Array ( [0] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Semmler, John G. ) ) ) [1] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Tucker, Kylie J. ) ) ) [2] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Allen, Trevor J. ) ) ) [3] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Proske, Uwe ) ) ) ) [IsPartOfRelationships] => Array ( [0] => Array ( [BibEntity] => Array ( [Dates] => Array ( [0] => Array ( [D] => 01 [M] => 01 [Type] => published [Y] => 2007 ) ) [Identifiers] => Array ( [0] => Array ( [Type] => issn-print [Value] => 87507587 ) [1] => Array ( [Type] => issn-locals [Value] => edsbas ) ) ) ) ) ) )
IllustrationInfo