From Scan to Simulation—A Novel Workflow for Developing Bioinspired Heart Valves

التفاصيل البيبلوغرافية
العنوان: From Scan to Simulation—A Novel Workflow for Developing Bioinspired Heart Valves
المؤلفون: Aeryne, Lee, Syamak, Farajikhah, Matthew, Crago, Luke, Mosse, David Frederick, Fletcher, Fariba, Dehghani, David Scott, Winlaw, Sina, Naficy
المصدر: Journal of Biomechanical Engineering. 145
بيانات النشر: ASME International, 2022.
سنة النشر: 2022
مصطلحات موضوعية: Sheep, Heart Valve Prosthesis, Aortic Valve, Physiology (medical), Models, Cardiovascular, Biomedical Engineering, Animals, X-Ray Microtomography, Stress, Mechanical, Prosthesis Design, Heart Valves, Workflow
الوصف: Current heart valve replacements lack durability and prolonged performance, especially in pediatric patients. In part, these problems may be attributed to the materials chosen for these constructs, but another important contributing factor is the design of the valve, as this dictates hemodynamic performance and impacts leaflet stresses which may accelerate structural valve deterioration. Most current era bioprosthetic valves adhere to a fundamental design where flat leaflets are supported by commissural posts, secured to a sewing ring. This overall design strategy is effective, but functionality and durability can be improved by incorporating features of the native valve geometry. This paper presents a novel workflow for developing and analyzing bio-inspired valve designs computationally. The leaflet curvature was defined using a mathematical equation whose parameters were derived from the three-dimensional model of a native sheep pulmonary valve obtained via microcomputed tomography. Finite element analysis was used to screen the various valve designs proposed in this study by assessing the effect of leaflet thickness, Young's modulus, and height/curvature on snap-through (where leaflets bend against their original curvature), geometric orifice area (GOA) and the stress in the leaflets. This workflow demonstrated benefits for valve designs with leaflet thicknesses between 0.1 and 0.3 mm, Young's moduli less than 50 MPa, and elongated leaflets with higher curvatures. The proposed workflow brings substantial efficiency gains at the design stage, minimizing manufacturing and animal testing during iterative improvements, and offers a bridge between in vitro and more complex in silico studies in the future.
تدمد: 1528-8951
0148-0731
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::081b532f14c4f5429139c9b5c0563658Test
https://doi.org/10.1115/1.4056353Test
حقوق: CLOSED
رقم الانضمام: edsair.doi.dedup.....081b532f14c4f5429139c9b5c0563658
قاعدة البيانات: OpenAIRE
ResultId 1
Header edsair
OpenAIRE
edsair.doi.dedup.....081b532f14c4f5429139c9b5c0563658
901
3

unknown
900.968627929688
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=edsair&AN=edsair.doi.dedup.....081b532f14c4f5429139c9b5c0563658&custid=s6537998&authtype=sso
FullText Array ( [Availability] => 0 )
Items Array ( [Name] => Title [Label] => Title [Group] => Ti [Data] => From Scan to Simulation—A Novel Workflow for Developing Bioinspired Heart Valves )
Array ( [Name] => Author [Label] => Authors [Group] => Au [Data] => <searchLink fieldCode="AR" term="%22Aeryne%2C+Lee%22">Aeryne, Lee</searchLink><br /><searchLink fieldCode="AR" term="%22Syamak%2C+Farajikhah%22">Syamak, Farajikhah</searchLink><br /><searchLink fieldCode="AR" term="%22Matthew%2C+Crago%22">Matthew, Crago</searchLink><br /><searchLink fieldCode="AR" term="%22Luke%2C+Mosse%22">Luke, Mosse</searchLink><br /><searchLink fieldCode="AR" term="%22David+Frederick%2C+Fletcher%22">David Frederick, Fletcher</searchLink><br /><searchLink fieldCode="AR" term="%22Fariba%2C+Dehghani%22">Fariba, Dehghani</searchLink><br /><searchLink fieldCode="AR" term="%22David+Scott%2C+Winlaw%22">David Scott, Winlaw</searchLink><br /><searchLink fieldCode="AR" term="%22Sina%2C+Naficy%22">Sina, Naficy</searchLink> )
Array ( [Name] => TitleSource [Label] => Source [Group] => Src [Data] => <i>Journal of Biomechanical Engineering</i>. 145 )
Array ( [Name] => Publisher [Label] => Publisher Information [Group] => PubInfo [Data] => ASME International, 2022. )
Array ( [Name] => DatePubCY [Label] => Publication Year [Group] => Date [Data] => 2022 )
Array ( [Name] => Subject [Label] => Subject Terms [Group] => Su [Data] => <searchLink fieldCode="DE" term="%22Sheep%22">Sheep</searchLink><br /><searchLink fieldCode="DE" term="%22Heart+Valve+Prosthesis%22">Heart Valve Prosthesis</searchLink><br /><searchLink fieldCode="DE" term="%22Aortic+Valve%22">Aortic Valve</searchLink><br /><searchLink fieldCode="DE" term="%22Physiology+%28medical%29%22">Physiology (medical)</searchLink><br /><searchLink fieldCode="DE" term="%22Models%2C+Cardiovascular%22">Models, Cardiovascular</searchLink><br /><searchLink fieldCode="DE" term="%22Biomedical+Engineering%22">Biomedical Engineering</searchLink><br /><searchLink fieldCode="DE" term="%22Animals%22">Animals</searchLink><br /><searchLink fieldCode="DE" term="%22X-Ray+Microtomography%22">X-Ray Microtomography</searchLink><br /><searchLink fieldCode="DE" term="%22Stress%2C+Mechanical%22">Stress, Mechanical</searchLink><br /><searchLink fieldCode="DE" term="%22Prosthesis+Design%22">Prosthesis Design</searchLink><br /><searchLink fieldCode="DE" term="%22Heart+Valves%22">Heart Valves</searchLink><br /><searchLink fieldCode="DE" term="%22Workflow%22">Workflow</searchLink> )
Array ( [Name] => Abstract [Label] => Description [Group] => Ab [Data] => Current heart valve replacements lack durability and prolonged performance, especially in pediatric patients. In part, these problems may be attributed to the materials chosen for these constructs, but another important contributing factor is the design of the valve, as this dictates hemodynamic performance and impacts leaflet stresses which may accelerate structural valve deterioration. Most current era bioprosthetic valves adhere to a fundamental design where flat leaflets are supported by commissural posts, secured to a sewing ring. This overall design strategy is effective, but functionality and durability can be improved by incorporating features of the native valve geometry. This paper presents a novel workflow for developing and analyzing bio-inspired valve designs computationally. The leaflet curvature was defined using a mathematical equation whose parameters were derived from the three-dimensional model of a native sheep pulmonary valve obtained via microcomputed tomography. Finite element analysis was used to screen the various valve designs proposed in this study by assessing the effect of leaflet thickness, Young's modulus, and height/curvature on snap-through (where leaflets bend against their original curvature), geometric orifice area (GOA) and the stress in the leaflets. This workflow demonstrated benefits for valve designs with leaflet thicknesses between 0.1 and 0.3 mm, Young's moduli less than 50 MPa, and elongated leaflets with higher curvatures. The proposed workflow brings substantial efficiency gains at the design stage, minimizing manufacturing and animal testing during iterative improvements, and offers a bridge between in vitro and more complex in silico studies in the future. )
Array ( [Name] => ISSN [Label] => ISSN [Group] => ISSN [Data] => 1528-8951<br />0148-0731 )
Array ( [Name] => URL [Label] => Access URL [Group] => URL [Data] => <link linkTarget="URL" linkTerm="https://explore.openaire.eu/search/publication?articleId=doi_dedup___::081b532f14c4f5429139c9b5c0563658" linkWindow="_blank">https://explore.openaire.eu/search/publication?articleId=doi_dedup___::081b532f14c4f5429139c9b5c0563658</link><br /><link linkTarget="URL" linkTerm="https://doi.org/10.1115/1.4056353" linkWindow="_blank">https://doi.org/10.1115/1.4056353</link> )
Array ( [Name] => Copyright [Label] => Rights [Group] => Cpyrght [Data] => CLOSED )
Array ( [Name] => AN [Label] => Accession Number [Group] => ID [Data] => edsair.doi.dedup.....081b532f14c4f5429139c9b5c0563658 )
RecordInfo Array ( [BibEntity] => Array ( [Languages] => Array ( [0] => Array ( [Text] => Undetermined ) ) [Subjects] => Array ( [0] => Array ( [SubjectFull] => Sheep [Type] => general ) [1] => Array ( [SubjectFull] => Heart Valve Prosthesis [Type] => general ) [2] => Array ( [SubjectFull] => Aortic Valve [Type] => general ) [3] => Array ( [SubjectFull] => Physiology (medical) [Type] => general ) [4] => Array ( [SubjectFull] => Models, Cardiovascular [Type] => general ) [5] => Array ( [SubjectFull] => Biomedical Engineering [Type] => general ) [6] => Array ( [SubjectFull] => Animals [Type] => general ) [7] => Array ( [SubjectFull] => X-Ray Microtomography [Type] => general ) [8] => Array ( [SubjectFull] => Stress, Mechanical [Type] => general ) [9] => Array ( [SubjectFull] => Prosthesis Design [Type] => general ) [10] => Array ( [SubjectFull] => Heart Valves [Type] => general ) [11] => Array ( [SubjectFull] => Workflow [Type] => general ) ) [Titles] => Array ( [0] => Array ( [TitleFull] => From Scan to Simulation—A Novel Workflow for Developing Bioinspired Heart Valves [Type] => main ) ) ) [BibRelationships] => Array ( [HasContributorRelationships] => Array ( [0] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Aeryne, Lee ) ) ) [1] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Syamak, Farajikhah ) ) ) [2] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Matthew, Crago ) ) ) [3] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Luke, Mosse ) ) ) [4] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => David Frederick, Fletcher ) ) ) [5] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Fariba, Dehghani ) ) ) [6] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => David Scott, Winlaw ) ) ) [7] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Sina, Naficy ) ) ) ) [IsPartOfRelationships] => Array ( [0] => Array ( [BibEntity] => Array ( [Dates] => Array ( [0] => Array ( [D] => 21 [M] => 12 [Type] => published [Y] => 2022 ) ) [Identifiers] => Array ( [0] => Array ( [Type] => issn-print [Value] => 15288951 ) [1] => Array ( [Type] => issn-print [Value] => 01480731 ) [2] => Array ( [Type] => issn-locals [Value] => edsair ) ) [Numbering] => Array ( [0] => Array ( [Type] => volume [Value] => 145 ) ) [Titles] => Array ( [0] => Array ( [TitleFull] => Journal of Biomechanical Engineering [Type] => main ) ) ) ) ) ) )
IllustrationInfo