دورية أكاديمية

Ten-year outcomes following small incision lenticule extraction for up to -10Dioptres myopia.

التفاصيل البيبلوغرافية
العنوان: Ten-year outcomes following small incision lenticule extraction for up to -10Dioptres myopia.
المؤلفون: Xia, Fei1 (AUTHOR), Chen, Zhuoyi1 (AUTHOR), Miao, Huamao1 (AUTHOR), Wei, Ruoyan1 (AUTHOR), Li, Meiyan1 (AUTHOR), Zhao, Jing1 (AUTHOR), Zhou, Xingtao1 (AUTHOR) doctzhouxingtao@163.com
المصدر: Clinical & Experimental Optometry. Apr2024, Vol. 107 Issue 3, p285-290. 6p.
مصطلحات موضوعية: *PHOTOREFRACTIVE keratectomy, *SMALL-incision lenticule extraction, *MYOPIA, *VISUAL acuity
مستخلص: More than 6 million small-incision lenticule extraction (SMILE) procedures have been performed worldwide since 2011. Therefore, its long-term safety and efficacy should be investigated. This study aimed to evaluate 10-year refractive outcomes, corneal stability, axial length, and wavefront aberrations in patients who underwent SMILE to correct myopia. Thirty two patients (32 eyes) who underwent SMILE-based myopic correction. Corrected distance visual acuity, uncorrected distance visual acuity, corneal stability, axial length, and wavefront aberrations were evaluated preoperatively and at 1 month and 1, 5, and 10 years postoperatively. At 10 years postoperatively, the safety and efficacy indices for the patients included in this study were 1.19 ± 0.21 and 1.04 ± 0.27, respectively. For 26 (81%) and 30 eyes (94%), correction to within ±0.50 D and ±1.00 D of the target was achieved, respectively. Over the 10-year follow-up duration, a mean −0.32 ± 0.56 D regression was observed (−0.03 ± 0.06 D/year). Relative to baseline, horizontal and vertical comas significantly increased, as did the incidence of higher-order aberrations (all P < 0.001), whereas axial length and corneal elevation remained stable during follow-up. These results indicate that the SMILE-based correction for myopia of up to -10 Dioptres is safe, effective, and stable, with relatively constant wavefront aberrations and corneal stability over time after treatment. [ABSTRACT FROM AUTHOR]
قاعدة البيانات: Academic Search Index
ResultId 1
Header asx
Academic Search Index
176532582
1430
6
Academic Journal
academicJournal
1430.19006347656
PLink https://search.ebscohost.com/login.aspx?direct=true&site=eds-live&scope=site&db=asx&AN=176532582&custid=s6537998&authtype=sso
FullText Array ( [Availability] => 0 )
Items Array ( [Name] => Title [Label] => Title [Group] => Ti [Data] => Ten-year outcomes following small incision lenticule extraction for up to -10Dioptres myopia. )
Array ( [Name] => Author [Label] => Authors [Group] => Au [Data] => &lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Xia%2C+Fei%22&quot;&gt;Xia, Fei&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Chen%2C+Zhuoyi%22&quot;&gt;Chen, Zhuoyi&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Miao%2C+Huamao%22&quot;&gt;Miao, Huamao&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Wei%2C+Ruoyan%22&quot;&gt;Wei, Ruoyan&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Li%2C+Meiyan%22&quot;&gt;Li, Meiyan&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Zhao%2C+Jing%22&quot;&gt;Zhao, Jing&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;br /&gt;&lt;searchLink fieldCode=&quot;AR&quot; term=&quot;%22Zhou%2C+Xingtao%22&quot;&gt;Zhou, Xingtao&lt;/searchLink&gt;&lt;relatesTo&gt;1&lt;/relatesTo&gt; (AUTHOR)&lt;i&gt; doctzhouxingtao@163.com&lt;/i&gt; )
Array ( [Name] => TitleSource [Label] => Source [Group] => Src [Data] => &lt;searchLink fieldCode=&quot;JN&quot; term=&quot;%22Clinical+%26+Experimental+Optometry%22&quot;&gt;Clinical &amp; Experimental Optometry&lt;/searchLink&gt;. Apr2024, Vol. 107 Issue 3, p285-290. 6p. )
Array ( [Name] => Subject [Label] => Subject Terms [Group] => Su [Data] => *&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22PHOTOREFRACTIVE+keratectomy%22&quot;&gt;PHOTOREFRACTIVE keratectomy&lt;/searchLink&gt;&lt;br /&gt;*&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22SMALL-incision+lenticule+extraction%22&quot;&gt;SMALL-incision lenticule extraction&lt;/searchLink&gt;&lt;br /&gt;*&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22MYOPIA%22&quot;&gt;MYOPIA&lt;/searchLink&gt;&lt;br /&gt;*&lt;searchLink fieldCode=&quot;DE&quot; term=&quot;%22VISUAL+acuity%22&quot;&gt;VISUAL acuity&lt;/searchLink&gt; )
Array ( [Name] => Abstract [Label] => Abstract [Group] => Ab [Data] => More than 6 million small-incision lenticule extraction (SMILE) procedures have been performed worldwide since 2011. Therefore, its long-term safety and efficacy should be investigated. This study aimed to evaluate 10-year refractive outcomes, corneal stability, axial length, and wavefront aberrations in patients who underwent SMILE to correct myopia. Thirty two patients (32 eyes) who underwent SMILE-based myopic correction. Corrected distance visual acuity, uncorrected distance visual acuity, corneal stability, axial length, and wavefront aberrations were evaluated preoperatively and at 1 month and 1, 5, and 10 years postoperatively. At 10 years postoperatively, the safety and efficacy indices for the patients included in this study were 1.19 &#177; 0.21 and 1.04 &#177; 0.27, respectively. For 26 (81%) and 30 eyes (94%), correction to within &#177;0.50 D and &#177;1.00 D of the target was achieved, respectively. Over the 10-year follow-up duration, a mean −0.32 &#177; 0.56 D regression was observed (−0.03 &#177; 0.06 D/year). Relative to baseline, horizontal and vertical comas significantly increased, as did the incidence of higher-order aberrations (all P &lt; 0.001), whereas axial length and corneal elevation remained stable during follow-up. These results indicate that the SMILE-based correction for myopia of up to -10 Dioptres is safe, effective, and stable, with relatively constant wavefront aberrations and corneal stability over time after treatment. [ABSTRACT FROM AUTHOR] )
RecordInfo Array ( [BibEntity] => Array ( [Identifiers] => Array ( [0] => Array ( [Type] => doi [Value] => 10.1080/08164622.2023.2203313 ) ) [Languages] => Array ( [0] => Array ( [Code] => eng [Text] => English ) ) [PhysicalDescription] => Array ( [Pagination] => Array ( [PageCount] => 6 [StartPage] => 285 ) ) [Subjects] => Array ( [0] => Array ( [SubjectFull] => PHOTOREFRACTIVE keratectomy [Type] => general ) [1] => Array ( [SubjectFull] => SMALL-incision lenticule extraction [Type] => general ) [2] => Array ( [SubjectFull] => MYOPIA [Type] => general ) [3] => Array ( [SubjectFull] => VISUAL acuity [Type] => general ) ) [Titles] => Array ( [0] => Array ( [TitleFull] => Ten-year outcomes following small incision lenticule extraction for up to -10Dioptres myopia. [Type] => main ) ) ) [BibRelationships] => Array ( [HasContributorRelationships] => Array ( [0] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Xia, Fei ) ) ) [1] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Chen, Zhuoyi ) ) ) [2] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Miao, Huamao ) ) ) [3] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Wei, Ruoyan ) ) ) [4] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Li, Meiyan ) ) ) [5] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Zhao, Jing ) ) ) [6] => Array ( [PersonEntity] => Array ( [Name] => Array ( [NameFull] => Zhou, Xingtao ) ) ) ) [IsPartOfRelationships] => Array ( [0] => Array ( [BibEntity] => Array ( [Dates] => Array ( [0] => Array ( [D] => 01 [M] => 04 [Text] => Apr2024 [Type] => published [Y] => 2024 ) ) [Identifiers] => Array ( [0] => Array ( [Type] => issn-print [Value] => 08164622 ) ) [Numbering] => Array ( [0] => Array ( [Type] => volume [Value] => 107 ) [1] => Array ( [Type] => issue [Value] => 3 ) ) [Titles] => Array ( [0] => Array ( [TitleFull] => Clinical & Experimental Optometry [Type] => main ) ) ) ) ) ) )
IllustrationInfo