Effect of surface electrode recording area on compound muscle action potential scan processing for motor unit number estimation

التفاصيل البيبلوغرافية
العنوان: Effect of surface electrode recording area on compound muscle action potential scan processing for motor unit number estimation
المؤلفون: Dan Zhang, Zhiyuan Lu, Weijun Gong, Ping Zhou
المصدر: Frontiers in Neuroscience, Vol 18 (2024)
بيانات النشر: Frontiers Media S.A., 2024.
سنة النشر: 2024
المجموعة: LCC:Neurosciences. Biological psychiatry. Neuropsychiatry
مصطلحات موضوعية: MScanFit, motor unit number estimation, compound muscle action potential scan, electromyography, electrode recording area, Neurosciences. Biological psychiatry. Neuropsychiatry, RC321-571
الوصف: IntroductionMScanFit is a model-based algorithm for motor unit number estimation (MUNE) from compound muscle action potential (CMAP) scan data. It is a clinically applicable tool because of its quick and automatic implementation. Electrodes with different recording areas were employed to record CMAP scan data in existing studies. However, the effect of electrode recording area on MScanFit MUNE and other CMAP scan parameters has not been studied.MethodsCMAP scan was performed on the abductor pollicis brevis muscle of both hands on 14 healthy subjects using three different electrodes with recording areas of 10 mm × 10 mm, 11 mm × 14 mm, and 22 mm × 26 mm, respectively. Motor unit number was estimated using MScanFit for each CMAP scan. Two motor unit number index parameters, i.e., D50 and step index (STEPIX), were also derived from the CMAP scan data.ResultsNo significant difference in D50, STEPIX, and MScanFit MUNE was observed across three different electrode recording areas, although the amplitude of CMAP decreased significantly when a larger electrode was used. Intraclass correlation coefficients of 0.792 and 0.782 were obtained for MScanFit MUNE and STEPIX, respectively.DiscussionCompared with CMAP amplitude, D50, STEPIX, and MScanFit MUNE are less sensitive to variation in electrode recording area. However, the repeatability of MScanFit MUNE could be compromised by the inconsistency in the electrode recording area.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1662-453X
العلاقة: https://www.frontiersin.org/articles/10.3389/fnins.2024.1382871/fullTest; https://doaj.org/toc/1662-453XTest
DOI: 10.3389/fnins.2024.1382871
الوصول الحر: https://doaj.org/article/3f8b7702d2ee442297968687f6a5bbb0Test
رقم الانضمام: edsdoj.3f8b7702d2ee442297968687f6a5bbb0
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1662453X
DOI:10.3389/fnins.2024.1382871