Miniature magnetically anchored and controlled camera system for trocar-less laparoscopy

التفاصيل البيبلوغرافية
العنوان: Miniature magnetically anchored and controlled camera system for trocar-less laparoscopy
المؤلفون: Fei Xue, Dinghui Dong, Junxi Xiang, Luo Yu, Haoyang Zhu, Yi Lv, Hongke Zhang, Rongqian Wu
المصدر: World Journal of Gastroenterology
بيانات النشر: Baishideng Publishing Group Inc, 2017.
سنة النشر: 2017
مصطلحات موضوعية: Male, Materials science, Time Factors, Trocar-less laparoscopy, Nephrectomy, 03 medical and health sciences, Magnetics, 0302 clinical medicine, Animal model, Light source, Dogs, Minimally invasive surgery, medicine, Animals, Cholecystectomy, Major complication, Laparoscopy, Laparoscopic cholecystectomy, Laparoscopic training, Miniaturization, medicine.diagnostic_test, Hexagonal crystal system, Gastroenterology, General Medicine, Equipment Design, Basic Study, Surgical Instruments, Magnetically anchored and controlled camera, Disease Models, Animal, 030220 oncology & carcinogenesis, Models, Animal, 030211 gastroenterology & hepatology, Biomedical engineering
الوصف: Aim To design a miniature magnetically anchored and controlled camera system to reduce the number of trocars which are required for laparoscopy. Methods The system consists of a miniature magnetically anchored camera with a 30° downward angle, an external magnetically anchored unit, and a vision output device. The camera weighs 12 g, measures Φ10.5 mm × 55 mm and has two magnets, a vision model, a light source, and a metal hexagonal nut. To test the prototype, the camera was inserted through a 12-mm conventional trocar in an ex vivo real liver laparoscopic training system. A trocar-less laparoscopic cholecystectomy was performed 6 times using a 12-mm and a 5-mm conventional trocar. In addition, the same procedure was performed in four canine models. Results Both procedures were successfully performed using only two conventional laparoscopic trocars. The cholecystectomy was completed without any major complication in 42 min (38-45 min) in vitro and in 50 min (45-53 min) using an animal model. This camera was anchored and controlled by an external unit magnetically anchored on the abdominal wall. The camera could generate excellent image. with no instrument collisions. Conclusion The camera system we designed provides excellent optics and can be easily maneuvered. The number of conventional trocars is reduced without adding technical difficulties.
اللغة: English
تدمد: 2219-2840
1007-9327
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::bf31b4042d1263a4b2f654bb466b4f24Test
http://europepmc.org/articles/PMC5374128Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....bf31b4042d1263a4b2f654bb466b4f24
قاعدة البيانات: OpenAIRE