-
1مؤتمر
المؤلفون: Balmer, J., Pretty, C., Kamoi, S., Davidson, S., Pironet, A., Desaive, Thomas, Shaw, G.M., Chase, J. G.
المصدر: IFAC-PapersOnLine, 50 (1), 856-861 (2017); 20th IFAC world congress, 11-17 juillet 2017
مصطلحات موضوعية: Bio-signals analysis, Biomedical systems, Cardiovascular, Electrocardiogram, Pre-ejection Period, Pulse transit time, Pulse wave velocity, Human health sciences, Anesthesia & intensive care, Sciences de la santé humaine, Anesthésie & soins intensifs
العلاقة: urn:issn:2405-8971; urn:issn:2405-8963
الوصول الحر: https://orbi.uliege.be/handle/2268/248184Test
-
2دورية أكاديمية
المؤلفون: Sun, Q.H., Chase, J.G., Zhou, C., Tawhai, M.H., Knopp, J.L., Moller, K., Heines, S.J., Bergmans, D.C., Shaw, G.M.
المصدر: Sun , Q H , Chase , J G , Zhou , C , Tawhai , M H , Knopp , J L , Moller , K , Heines , S J , Bergmans , D C & Shaw , G M 2022 , ' Prediction and estimation of pulmonary response and elastance evolution for volume-controlled and pressure-controlled ventilation ' , Biomedical Signal Processing and Control , vol. 72 , 103367 . https://doi.org/10.1016/j.bspc.2021.103367Test
مصطلحات موضوعية: Volume control ventilation, Pressure control ventilation, Positive end expiratory pressure, Respiratory mechanics, Elastance, Basis function, RESPIRATORY-DISTRESS-SYNDROME, END-EXPIRATORY PRESSURE, ACUTE LUNG INJURY, MECHANICAL VENTILATION, RECRUITMENT MANEUVERS, MODEL, PEEP, OPTIMIZATION, PARAMETER, STRATEGY
وصف الملف: application/pdf
الإتاحة: https://doi.org/10.1016/j.bspc.2021.103367Test
https://cris.maastrichtuniversity.nl/en/publications/ec3472de-02b1-449e-9a70-b57768541d85Test
https://cris.maastrichtuniversity.nl/ws/files/88051224/Bergmans_2022_Prediction_and_estimation_of_pulmonary.pdfTest -
3دورية أكاديمية
المؤلفون: Cushway, James, Murphy, L., Chase, J.G., Shaw, G.M., Desaive, Thomas
المصدر: Computer Methods and Programs in Biomedicine, 220 (2022)
مصطلحات موضوعية: Cardio-pulmonary, Cardiovascular, Positive end-expiratory pressure, Stressed blood volume, Thoracic pressure, Cardiovascular system, Economic and social effects, Hemodynamics, Mammals, Physiological models, Ventilation, Blood volumes, Chamber model, Hemodynamic parameters, Mechanical ventilation, Parameters estimation, Positive end expiratory pressures, Parameter estimation, airway pressure, animal experiment, animal model, aortic pressure, article, artificial ventilation, blood volume, cava vein, compliance (physical), controlled study, heart left ventricle volume, lung model
العلاقة: urn:issn:0169-2607; urn:issn:1872-7565; https://orbi.uliege.be/handle/2268/310638Test; info:hdl:2268/310638; https://orbi.uliege.be/bitstream/2268/310638/1/1-s2.0-S0169260722002012-main.pdfTest; scopus-id:2-s2.0-85128672129; info:pmid:35461125
الإتاحة: https://doi.org/10.1016/j.cmpb.2022.106819Test
https://orbi.uliege.be/handle/2268/310638Test
https://orbi.uliege.be/bitstream/2268/310638/1/1-s2.0-S0169260722002012-main.pdfTest -
4مؤتمر
المؤلفون: Thomas, Felicity Louise, Pretty, C.P., Shaw, G.M., Chase, J.G.
مصطلحات موضوعية: Engineering, computing & technology :: Mechanical engineering, Ingénierie, informatique & technologie :: Ingénierie mécanique
جغرافية الموضوع: international
العلاقة: 14th Annual Diabetes Technology Meeting (DTM) (06-11-2014 to 08-11-2014)
الوصول الحر: https://orbi.uliege.be/handle/2268/196590Test
-
5مؤتمر
المؤلفون: Thomas, Felicity Louise, Signal, M.K., Shaw, G.M., Chase, J.G.
مصطلحات موضوعية: Engineering, computing & technology :: Multidisciplinary, general & others, Ingénierie, informatique & technologie :: Multidisciplinaire, généralités & autres
جغرافية الموضوع: international
العلاقة: 13th Annual Diabetes Technology Meeting (DTM) (31-10-2013 to 02-11-2013)
الوصول الحر: https://orbi.uliege.be/handle/2268/196591Test
-
6دورية أكاديمية
المؤلفون: Sun, Q.H., Chase, J.G., Zhou, C., Tawhai, M.H., Knopp, J.L., Moller, K., Heines, S.J., Bergmans, D.C., Shaw, G.M.
المصدر: Sun , Q H , Chase , J G , Zhou , C , Tawhai , M H , Knopp , J L , Moller , K , Heines , S J , Bergmans , D C & Shaw , G M 2021 , Minimal Lung Mechanics Basis-functions for a Mechanical Ventilation Virtual Patient . in IFAC PAPERSONLINE . 15 edn , vol. 54 , Elsevier , pp. 127-132 , 11th IFAC Symposium on Biological and Medical Systems , Ghent , Belgium , 19/09/21 . https://doi.org/10.1016/j.ifacol.2021.10.243Test
مصطلحات موضوعية: Mechanical ventilation, PEEP, Respiratory mechanics, Elastance, Prediction, VILI, Basis function, System identification, Virtual patient, PRESSURE, MODEL
وصف الملف: application/pdf
الإتاحة: https://doi.org/10.1016/j.ifacol.2021.10.243Test
https://cris.maastrichtuniversity.nl/en/publications/8cda812f-c417-4387-9672-d0f35c880cecTest
https://cris.maastrichtuniversity.nl/ws/files/88051289/Bergmans_2021_Minimal_lung_mechanics_basis_functions_for.pdfTest -
7دورية أكاديمية
المؤلفون: Zhou, C., Chase, J.G., Knopp, J., Sun, Q.H., Tawhai, M., Moller, K., Heines, S.J., Bergmans, D.C., Shaw, G.M., Desaive, T.
المصدر: Zhou , C , Chase , J G , Knopp , J , Sun , Q H , Tawhai , M , Moller , K , Heines , S J , Bergmans , D C , Shaw , G M & Desaive , T 2021 , ' Virtual patients for mechanical ventilation in the intensive care unit ' , Computer Methods and Programs in Biomedicine , vol. 199 , 105912 . https://doi.org/10.1016/j.cmpb.2020.105912Test
مصطلحات موضوعية: digital twins, hysteresis loop analysis, hysteresis model, lung mechanics, mechanical ventilation, virtual patient
وصف الملف: application/pdf
الإتاحة: https://doi.org/10.1016/j.cmpb.2020.105912Test
https://cris.maastrichtuniversity.nl/en/publications/e420aeea-8927-4bc4-9874-b3326c1f11ddTest
https://cris.maastrichtuniversity.nl/ws/files/88051339/Bergmans_2021_Virtual_patients_for_mechanical_ventilation.pdfTest -
8دورية أكاديمية
المؤلفون: Smith, R., Pretty, C.G., Shaw, G.M., Desaive, Thomas, Chase, J.G.
المصدر: Computers in Biology and Medicine, 139 (2021)
مصطلحات موضوعية: Fluid responsiveness, Fluid resuscitation, Hemodynamic monitoring, Intensive care unit, Mathematical modelling, Forecasting, Mammals, Parameter estimation, Resuscitation, Areas under the curves, Fluid response, Fluid therapy, Mathematical modeling, Model-based OPC, Polar plot, Stroke volumes, Intensive care units, animal experiment, animal model, aortic flow, area under the curve, article, calibration, control system, heart function, heart stroke volume, human, limit of agreement, nonhuman, pig
العلاقة: urn:issn:0010-4825; urn:issn:1879-0534; https://orbi.uliege.be/handle/2268/309464Test; info:hdl:2268/309464; https://orbi.uliege.be/bitstream/2268/309464/1/Predicting%20Fluid%20Responsiveness%20-%20PRINT.pdfTest; scopus-id:2-s2.0-85117398073; info:pmid:34678480
الإتاحة: https://doi.org/10.1016/j.compbiomed.2021.104950Test
https://orbi.uliege.be/handle/2268/309464Test
https://orbi.uliege.be/bitstream/2268/309464/1/Predicting%20Fluid%20Responsiveness%20-%20PRINT.pdfTest -
9دورية أكاديمية
المؤلفون: Smith, R., Chase, J.G., Pretty, C.G., Davidson, S., Shaw, G.M., Desaive, Thomas
المصدر: Computers in Biology and Medicine, 135 (2021)
مصطلحات موضوعية: End-diastolic volume, Fluid responsiveness, Frank-starling curves, Hemodynamic monitoring, Intensive care unit, Preload, Failure (mechanical), Hemodynamics, Intensive care units, Mammals, Patient treatment, Physiological models, End-diastolic, Frank-starling curve, Haemodynamics, Intensive care, Left ventricles, Preloads, Stroke volumes, Catheters, cisatracurium, diazepam, infusion fluid, sufentanil, thiobarbital, tiletamine plus zolazepam, animal experiment, animal model, aortic flow, arterial pressure
العلاقة: urn:issn:0010-4825; urn:issn:1879-0534; https://orbi.uliege.be/handle/2268/309465Test; info:hdl:2268/309465; https://orbi.uliege.be/bitstream/2268/309465/1/Preload___Frank_Starling_Curves%20-%20PRINT.pdfTest; scopus-id:2-s2.0-85109433292; info:pmid:34247132
الإتاحة: https://doi.org/10.1016/j.compbiomed.2021.104627Test
https://orbi.uliege.be/handle/2268/309465Test
https://orbi.uliege.be/bitstream/2268/309465/1/Preload___Frank_Starling_Curves%20-%20PRINT.pdfTest -
10دورية أكاديمية
المؤلفون: Smith, R., Murphy, L., Pretty, C.G., Desaive, Thomas, Shaw, G.M., Chase, J.G.
المصدر: Computer Methods and Programs in Biomedicine, 204 (2021)
مصطلحات موضوعية: Arterial wave reflection, Hemodynamic monitoring, Intensive care, Pulse contour analysis, Stroke volume, Tube-load model, Mammals, Hemodynamic instability, Load models, Pulse transit time, Pulse-contour analysis, States change, Stroke volumes, Hemodynamics, cisatracurium, diazepam, Escherichia coli endotoxin, sodium chloride, sufentanil, thiobarbital, tiletamine plus zolazepam, anesthesia, animal experiment, animal tissue, aorta, aortic flow, aortic valve, arterial pressure, Article, blood vessel tone
العلاقة: urn:issn:0169-2607; urn:issn:1872-7565; https://orbi.uliege.be/handle/2268/309463Test; info:hdl:2268/309463; https://orbi.uliege.be/bitstream/2268/309463/1/Tube_Load_Model_RSmith%20-%20PRINT.pdfTest; scopus-id:2-s2.0-85104120915; info:pmid:33813060
الإتاحة: https://doi.org/10.1016/j.cmpb.2021.106062Test
https://orbi.uliege.be/handle/2268/309463Test
https://orbi.uliege.be/bitstream/2268/309463/1/Tube_Load_Model_RSmith%20-%20PRINT.pdfTest