-
1دورية أكاديمية
المساهمون: Clinicum, HUS Comprehensive Cancer Center, Department of Oncology
مصطلحات موضوعية: Computer-assisted, Neoplasm metastasis, Palliative care, Radiotherapy planning, Radiotherapy setup errors, 3122 Cancers
وصف الملف: application/pdf
العلاقة: Larjavaara , S , Strengell , S , Seppälä , T , Tenhunen , M & Anttonen , A 2023 , ' Palliative intensity modulated radiotherapy of bone metastases based on diagnostic instead of planning computed tomography scans ' , Physics and Imaging in Radiation Oncology , vol. 27 , 100456 . https://doi.org/10.1016/j.phro.2023.100456Test; http://hdl.handle.net/10138/573367Test; 5980f951-1dbd-4354-aff1-ce8560995d53; 001168013700001
-
2دورية أكاديمية
المؤلفون: Suvi Larjavaara, Satu Strengell, Tiina Seppälä, Mikko Tenhunen, Anu Anttonen
المصدر: Physics and Imaging in Radiation Oncology, Vol 27, Iss , Pp 100456- (2023)
مصطلحات موضوعية: Palliative care, Radiotherapy setup errors, Radiotherapy planning, Computer-assisted, Neoplasm metastasis, Medical physics. Medical radiology. Nuclear medicine, R895-920, Neoplasms. Tumors. Oncology. Including cancer and carcinogens, RC254-282
وصف الملف: electronic resource
العلاقة: http://www.sciencedirect.com/science/article/pii/S2405631623000477Test; https://doaj.org/toc/2405-6316Test
-
3دورية أكاديمية
المؤلفون: Tamil Selvan Kasirajan, Padma Ganesan, Revathy Murugesan Kesavan, Arunai Nambi Raj N, Senthilnathan K, Ramesh Babu P
المصدر: Iranian Journal of Medical Physics, Vol 17, Iss 5, Pp 308-315 (2020)
مصطلحات موضوعية: radiotherapy, patient positioning, radiosurgery, radiotherapy setup errors, immobilization, Medical physics. Medical radiology. Nuclear medicine, R895-920
وصف الملف: electronic resource
العلاقة: http://ijmp.mums.ac.ir/article_14033_43e7e82560ce1e894362e02c63e92160.pdfTest; https://doaj.org/toc/2345-3672Test
-
4دورية أكاديمية
المؤلفون: Chunga-Palomino, Sara Luz
المساهمون: Universidad Universidad de Verona en Italia, Centro Internacional de Física Teórica Abdus Salam, Universidad Nacional de Piura
المصدر: Pinar del Rio Journal of Medical Sciences; Vol. 25, No. 5 (2021): Septiembre-octubre; e5209 ; Revista de Ciencias Médicas de Pinar del Río; Vol. 25, No. 5 (2021): Septiembre-octubre; e5209 ; 1561-3194
مصطلحات موضوعية: NEOPLASIAS DE LA PRÓSTATA, ADENOCARCINOMA, ERRORES DE CONFIGURACIÓN EN RADIOTERAPIA, TOMOGRAFÍA COMPUTARIZADA POR RAYOS X, PACIENTE, PROSTATIC NEOPLASMS, RADIOTHERAPY SETUP ERRORS, TOMOGRAPHY, X-RAY COMPUTED, PATIENT
وصف الملف: application/pdf
العلاقة: http://revcmpinar.sld.cu/index.php/publicaciones/article/view/5209/pdfTest; http://revcmpinar.sld.cu/index.php/publicaciones/article/downloadSuppFile/5209/1015Test; http://revcmpinar.sld.cu/index.php/publicaciones/article/downloadSuppFile/5209/1016Test; Muñoz Á. Personalidades históricas de la radioterapia. Revista Medicina [Internet]. 2021 [citado 28/8/2021]; 43(1): 11-17. Disponible en: http://revistamedicina.net/ojsanm/index.php/Medicina/article/view/1580Test; Raaymakers B W, Jürgenliemk-Schulz I M, Bol G H, Glitzner M, Kotte A N T J, Van Asselen B, et al. First patients treated with a 1.5 T MRI-Linac: Clinical proof of concept of a high-precision, high-field MRI guided radiotherapy treatment. Phys Med Biol [Internet]. 2017 [citado 28/8/2021]; 62(23): 41-50. Disponible en: https://doi.org/10.1088/1361-6560/aa9517Test; Pouget JP, Georgakilas AG, Ravanat JL. Targeted and off-target (bystander and abscopal) effects of radiation therapy: redox mechanisms and risk/benefit analysis. Antioxid Redox Signal [Internet]. 2018 [citado 28/8/2021]; 29(15): 1447-1487. Disponible en: http://doi.org/10.1089/ars.2017.7267Test; Van Herk M, Kooy HM. Automatic three-dimensional correlation of CT-CT, CT-MRI, and CT-SPECT using chamfer matching. Med. Phys [Internet]. 1994 [citado 28/8/2021]; 21(7): 1163–1178. Disponible en: https://doi.org/10.1118/1.597344Test; Zhong R, Song Y, Yang Y, Wang X, Li S, Zhou J, et al. Analysis of which local set-up errors can be covered by a 5-mm margin for cone beam CT-guided radiotherapy for nasopharyngeal carcinoma. Br J Radiol [Internet]. 2018 [citado 28/8/2021]; 91(1088): 20160849. Disponible en: http://doi.org/10.1259/bjr.20160849Test; Meier V, Staudinger C, Radonic S, Besserer J, Schneider U, Walsh L, et al. Reducing margins for abdominopelvic tumours in dogs: Impact on dose‐coverage and normal tissue complication probability. Vet Comp Oncol [Internet]. 2021 [citado 28/8/2021]; 19(2): 266-274. Disponible en: http://doi.org/10.1111/vco.12671Test; Castro P, Roch M, Zapatero A, Buchser D, Garayoa J, Anson C, et al. Multicomponent Assessment of the Geometrical Uncertainty and Consequent Margins in Prostate Cancer Radiotherapy Treatment Using Fiducial Markers. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology [Internet]. 2018 [citado 28/8/2021]; 7(4): 503-521. Disponible en: https://doi.org/10.4236/ijmpcero.2018.74043Test; García-Mollá R, Sánchez Rubio P, Bonaque Alandí J, Carrasco Herrera MA, Lliso Valverde F. Implementación y uso clínico de la radioterapia adaptativa. Informe del grupo de trabajo de radioterapia adaptativa de la Sociedad Española de Física Médica (SEFM). Rev Fis Med [Internet]. 2021 [citado 28/8/2021]; 22(1): 123-66. Disponible en: https://doi.org/10.37004/sefm/2021.22.1.004Test; Yock AD, Mohan R, Flampouri S, Bosch W, Taylor PA, Gladstone D, et al. Robustness analysis for external beam radiation therapy treatment plans: describing uncertainty scenarios and reporting their dosimetric consequences. Pract Radiat Oncol [Internet] 2019 [citado 28/8/2021]; 9(4): 200-207. Disponible en: https://pubmed.ncbi.nlm.nih.gov/30562614Test/; Basu T, Goldsworthy S, Gkoutos GV. A Sentence Classification Framework to Identify Geometric Errors in Radiation Therapy from Relevant Literature. Information [Internet]. 2021 [citado 28/8/2021]; 12(4): 139. Disponible en: https://doi.org/10.3390/info12040139Test; Kershaw L, Van Zadelhoff L, Heemsbergen W, Pos F, Van Herk M. Image guided radiation therapy strategies for pelvic lymph node irradiation in high-risk prostate cancer: motion and margins. Int J Radiat Oncol Biol Phys [Internet]. 2018 [citado 28/8/2021]; 100(1): 68-77. Disponible en: http://doi.org/10.1016/j.ijrobp.2017.08.044Test; 13. Banos‐Capilla MC, Lago-Martin JD, Gil P, Larrea LM. Sensitivity and specificity analysis of 2D small field measurement array: Patient‐specific quality assurance of small target treatments and spatially fractionated radiotherapy. J Appl Clin Med Phys [Internet]. 2021 [citado 28/8/2021]; 22(10): 104-119. Disponible en: http://doi.org/10.1002/acm2.13402Test; Guzmán-Rivera JV, Alvira-Guauña DC. Efectos secundarios de las ter¬apias oncológicas en pacientes con cáncer de cérvix. Rev. cienc. cui¬dad [Internet]. 2021 [citado 28/8/2021]; 18(2): 55-68. Disponible en: https://doi.org/10.22463/17949831.2842Test; Thaper D, Oinam AS, Kamal R, Singh G, Handa B, Kumar V, et al. Interplay effect modeling in stereotactic body radiotherapy treatment of liver cancer using volumetric modulated arc therapy. Phys Eng Sci Med [Internet]. 2021 [citado 28/8/2021]; 44(1): 123-134. Disponible en: http://doi.org/10.1007/s13246-020-00961-5Test; Sanchez Forero RA, Olejua Villa PA, Rocha Morales A, Murillo R. Evaluación de Errores de Posicionamiento en los 6 Grados de Libertad en Pacientes con Cáncer de próstata tratados con radioterapia. Urol Colomb [Internet]. 2021 [citado 28/8/2021]; 30(1): 23–33. Disponible en: https://www.thieme-connect.com/products/ejournals/abstract/10.1055/s-0040-1714726Test; Dai X, Lei Y, Wang T, Dhabaan AH, McDonald M, Beitler JJ, et al. Synthetic MRI-aided Head-and-Neck Organs-at-Risk Auto-Delineation for CBCT-guided Adaptive Radiotherapy. arXiv [Internet]. 2020 [citado 28/8/2021]; 1. Disponible en: https://arxiv.org/pdf/2010.04275.pdfTest; Pokhrel D, Sanford L, Halfman M, Molloy J. Potential reduction of lung dose via VMAT with jaw tracking in the treatment of single‐isocenter/two‐lesion lung SBRT. J Appl Clin Med Phys [Internet]. 2019 [citado 28/8/2021]; 20(5): 55-63. Disponible en: http://doi.org/10.1002/acm2.12580Test; Patni N, Burela N, Pasricha R, Goyal J, Soni TP, Kumar TS, et al. Assessment of three-dimensional setup errors in image-guided pelvic radiotherapy for uterine and cervical cancer using kilovoltage cone-beam computed tomography and its effect on planning target volume margins. J Cancer Res Ther [Internet]. 2017 [citado 28/8/2021]; 13(1): 131-136. Disponible en: http://doi.org/10.4103/0973-1482.199451Test; Lee DS, Lee YK, Kang YM, Won YG, Park S, Kim Y, et al. Assessment of planning reproducibility in three-dimensional field-in-field radiotherapy technique for breast cancer: impact of surgery-simulation interval. Sci Rep [Internet]. 2021 [citado 28/8/2021]; 11(1): 1556. Disponible en: http://doi.org/10.1038/s41598-020-78666-8Test; Chen Z, Yang Z, Wang J, Hu W. Dosimetric impact of different bladder and rectum filling during prostate cancer radiotherapy. Radiat Oncol [Internet]. 2016 [citado 28/8/2021]; 11(103). Disponible en: https://doi.org//10.1186/s13014-016-0681-zTest; http://revcmpinar.sld.cu/index.php/publicaciones/article/view/5209Test
الإتاحة: https://doi.org/10.1088/1361-6560/aa9517Test
https://doi.org/10.1089/ars.2017.7267Test
https://doi.org/10.1118/1.597344Test
https://doi.org/10.1259/bjr.20160849Test
https://doi.org/10.1111/vco.12671Test
https://doi.org/10.4236/ijmpcero.2018.74043Test
https://doi.org/10.37004/sefm/2021.22.1.004Test
https://doi.org/10.3390/info12040139Test
https://doi.org/10.1016/j.ijrobp.2017.08.044Test
https://doi.org/10.1002/acm2.13402Test -
5دورية أكاديمية
المؤلفون: Chunga-Palomino, Sara Luz
المساهمون: Universidad Universidad de Verona en Italia, Centro Internacional de Física Teórica Abdus Salam, Universidad Nacional de Piura
المصدر: Revista de ciencias médicas de Pinar del Río; Vol. 25, No. 5 (2021); e5209 ; 1561-3194
مصطلحات موضوعية: PROSTATIC NEOPLASMS, ADENOCARCINOMA, RADIOTHERAPY SETUP ERRORS, TOMOGRAPHY, X-RAY COMPUTED, PATIENT, NEOPLASIAS DE LA PRÓSTATA, ERRORES DE CONFIGURACIÓN EN RADIOTERAPIA, TOMOGRAFÍA COMPUTARIZADA POR RAYOS X, PACIENTE
وصف الملف: application/pdf
العلاقة: https://revcmpinar.sld.cu/index.php/publicaciones/article/view/5209/pdfTest; https://revcmpinar.sld.cu/index.php/publicaciones/article/downloadSuppFile/5209/1015Test; https://revcmpinar.sld.cu/index.php/publicaciones/article/downloadSuppFile/5209/1016Test; Muñoz Á. Personalidades históricas de la radioterapia. Revista Medicina [Internet]. 2021 [citado 28/8/2021]; 43(1): 11-17. Disponible en: http://revistamedicina.net/ojsanm/index.php/Medicina/article/view/1580Test; Raaymakers B W, Jürgenliemk-Schulz I M, Bol G H, Glitzner M, Kotte A N T J, Van Asselen B, et al. First patients treated with a 1.5 T MRI-Linac: Clinical proof of concept of a high-precision, high-field MRI guided radiotherapy treatment. Phys Med Biol [Internet]. 2017 [citado 28/8/2021]; 62(23): 41-50. Disponible en: https://doi.org/10.1088/1361-6560/aa9517Test; Pouget JP, Georgakilas AG, Ravanat JL. Targeted and off-target (bystander and abscopal) effects of radiation therapy: redox mechanisms and risk/benefit analysis. Antioxid Redox Signal [Internet]. 2018 [citado 28/8/2021]; 29(15): 1447-1487. Disponible en: http://doi.org/10.1089/ars.2017.7267Test; Van Herk M, Kooy HM. Automatic three-dimensional correlation of CT-CT, CT-MRI, and CT-SPECT using chamfer matching. Med. Phys [Internet]. 1994 [citado 28/8/2021]; 21(7): 1163–1178. Disponible en: https://doi.org/10.1118/1.597344Test; Zhong R, Song Y, Yang Y, Wang X, Li S, Zhou J, et al. Analysis of which local set-up errors can be covered by a 5-mm margin for cone beam CT-guided radiotherapy for nasopharyngeal carcinoma. Br J Radiol [Internet]. 2018 [citado 28/8/2021]; 91(1088): 20160849. Disponible en: http://doi.org/10.1259/bjr.20160849Test; Meier V, Staudinger C, Radonic S, Besserer J, Schneider U, Walsh L, et al. Reducing margins for abdominopelvic tumours in dogs: Impact on dose‐coverage and normal tissue complication probability. Vet Comp Oncol [Internet]. 2021 [citado 28/8/2021]; 19(2): 266-274. Disponible en: http://doi.org/10.1111/vco.12671Test; Castro P, Roch M, Zapatero A, Buchser D, Garayoa J, Anson C, et al. Multicomponent Assessment of the Geometrical Uncertainty and Consequent Margins in Prostate Cancer Radiotherapy Treatment Using Fiducial Markers. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology [Internet]. 2018 [citado 28/8/2021]; 7(4): 503-521. Disponible en: https://doi.org/10.4236/ijmpcero.2018.74043Test; García-Mollá R, Sánchez Rubio P, Bonaque Alandí J, Carrasco Herrera MA, Lliso Valverde F. Implementación y uso clínico de la radioterapia adaptativa. Informe del grupo de trabajo de radioterapia adaptativa de la Sociedad Española de Física Médica (SEFM). Rev Fis Med [Internet]. 2021 [citado 28/8/2021]; 22(1): 123-66. Disponible en: https://doi.org/10.37004/sefm/2021.22.1.004Test; Yock AD, Mohan R, Flampouri S, Bosch W, Taylor PA, Gladstone D, et al. Robustness analysis for external beam radiation therapy treatment plans: describing uncertainty scenarios and reporting their dosimetric consequences. Pract Radiat Oncol [Internet] 2019 [citado 28/8/2021]; 9(4): 200-207. Disponible en: https://pubmed.ncbi.nlm.nih.gov/30562614Test/; Basu T, Goldsworthy S, Gkoutos GV. A Sentence Classification Framework to Identify Geometric Errors in Radiation Therapy from Relevant Literature. Information [Internet]. 2021 [citado 28/8/2021]; 12(4): 139. Disponible en: https://doi.org/10.3390/info12040139Test; Kershaw L, Van Zadelhoff L, Heemsbergen W, Pos F, Van Herk M. Image guided radiation therapy strategies for pelvic lymph node irradiation in high-risk prostate cancer: motion and margins. Int J Radiat Oncol Biol Phys [Internet]. 2018 [citado 28/8/2021]; 100(1): 68-77. Disponible en: http://doi.org/10.1016/j.ijrobp.2017.08.044Test; 13. Banos‐Capilla MC, Lago-Martin JD, Gil P, Larrea LM. Sensitivity and specificity analysis of 2D small field measurement array: Patient‐specific quality assurance of small target treatments and spatially fractionated radiotherapy. J Appl Clin Med Phys [Internet]. 2021 [citado 28/8/2021]; 22(10): 104-119. Disponible en: http://doi.org/10.1002/acm2.13402Test; Guzmán-Rivera JV, Alvira-Guauña DC. Efectos secundarios de las ter¬apias oncológicas en pacientes con cáncer de cérvix. Rev. cienc. cui¬dad [Internet]. 2021 [citado 28/8/2021]; 18(2): 55-68. Disponible en: https://doi.org/10.22463/17949831.2842Test; Thaper D, Oinam AS, Kamal R, Singh G, Handa B, Kumar V, et al. Interplay effect modeling in stereotactic body radiotherapy treatment of liver cancer using volumetric modulated arc therapy. Phys Eng Sci Med [Internet]. 2021 [citado 28/8/2021]; 44(1): 123-134. Disponible en: http://doi.org/10.1007/s13246-020-00961-5Test; Sanchez Forero RA, Olejua Villa PA, Rocha Morales A, Murillo R. Evaluación de Errores de Posicionamiento en los 6 Grados de Libertad en Pacientes con Cáncer de próstata tratados con radioterapia. Urol Colomb [Internet]. 2021 [citado 28/8/2021]; 30(1): 23–33. Disponible en: https://www.thieme-connect.com/products/ejournals/abstract/10.1055/s-0040-1714726Test; Dai X, Lei Y, Wang T, Dhabaan AH, McDonald M, Beitler JJ, et al. Synthetic MRI-aided Head-and-Neck Organs-at-Risk Auto-Delineation for CBCT-guided Adaptive Radiotherapy. arXiv [Internet]. 2020 [citado 28/8/2021]; 1. Disponible en: https://arxiv.org/pdf/2010.04275.pdfTest; Pokhrel D, Sanford L, Halfman M, Molloy J. Potential reduction of lung dose via VMAT with jaw tracking in the treatment of single‐isocenter/two‐lesion lung SBRT. J Appl Clin Med Phys [Internet]. 2019 [citado 28/8/2021]; 20(5): 55-63. Disponible en: http://doi.org/10.1002/acm2.12580Test; Patni N, Burela N, Pasricha R, Goyal J, Soni TP, Kumar TS, et al. Assessment of three-dimensional setup errors in image-guided pelvic radiotherapy for uterine and cervical cancer using kilovoltage cone-beam computed tomography and its effect on planning target volume margins. J Cancer Res Ther [Internet]. 2017 [citado 28/8/2021]; 13(1): 131-136. Disponible en: http://doi.org/10.4103/0973-1482.199451Test; Lee DS, Lee YK, Kang YM, Won YG, Park S, Kim Y, et al. Assessment of planning reproducibility in three-dimensional field-in-field radiotherapy technique for breast cancer: impact of surgery-simulation interval. Sci Rep [Internet]. 2021 [citado 28/8/2021]; 11(1): 1556. Disponible en: http://doi.org/10.1038/s41598-020-78666-8Test; Chen Z, Yang Z, Wang J, Hu W. Dosimetric impact of different bladder and rectum filling during prostate cancer radiotherapy. Radiat Oncol [Internet]. 2016 [citado 28/8/2021]; 11(103). Disponible en: https://doi.org//10.1186/s13014-016-0681-zTest; https://revcmpinar.sld.cu/index.php/publicaciones/article/view/5209Test
الإتاحة: https://doi.org/10.1088/1361-6560/aa951710.1089/ars.2017.726710.1118/1.59734410.1259/bjr.2016084910.1111/vco.1267110.4236/ijmpcero.2018.7404310.37004/sefm/2021.22.1.00410.3390/info1204013910.1016/j.ijrobp.2017.08.04410.1002/acm2.1340210.22463/17949831.284210.1007/s13246-020-00961-510.1002/acm2.1258010.4103/0973-1482.19945110.1038/s41598-020-78666-8Test
https://revcmpinar.sld.cu/index.php/publicaciones/article/view/5209Test -
6
المؤلفون: Isabella, Fornacon-Wood, Hitesh, Mistry, Corinne, Johnson-Hart, Corinne, Faivre-Finn, James P B, O'Connor, Gareth J, Price
المصدر: Radiotherapy and Oncology. 176:53-58
مصطلحات موضوعية: Lung Neoplasms, Oncology, Radiotherapy Planning, Computer-Assisted, Humans, Bayes Theorem, Radiology, Nuclear Medicine and imaging, Hematology, Radiotherapy Setup Errors, Retrospective Studies, Radiotherapy, Image-Guided
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::4fb46ec14e168e05d74a9281da3d9de6Test
https://doi.org/10.1016/j.radonc.2022.09.009Test -
7
المصدر: Physica Medica. 98:81-87
مصطلحات موضوعية: Tattooing, Patient positioning, Radiotherapy Planning, Computer-Assisted, Biophysics, General Physics and Astronomy, Breast Neoplasms, General Medicine, Radiotherapy Setup Errors, Radiosurgery, ExacTrac, Breast cancer, Humans, Female, Radiology, Nuclear Medicine and imaging, Radiotherapy, Image-Guided, Motion management
وصف الملف: application/pdf
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::46c9e621e4fde874bf413d8a3a5587e6Test
https://nagoya.repo.nii.ac.jp/records/2003986Test -
8
المؤلفون: Supriya Chopra, Shyamkishore Shrivastava, A. Dheera, D. Epili, Umesh Mahantshetty, P. Naga, Libin Scaria, Yogesh Ghadi, G. Lavanya, A. Nachankar
المصدر: Clinical Oncology. 34:189-197
مصطلحات موضوعية: Tumour regression, medicine.medical_treatment, Planning target volume, Uterine Cervical Neoplasms, Anterior margin, Cervix Uteri, Radiotherapy Setup Errors, Organ Motion, medicine, Humans, Radiology, Nuclear Medicine and imaging, Prospective Studies, Prospective cohort study, Image-guided radiation therapy, Cervical cancer, business.industry, Radiotherapy Planning, Computer-Assisted, Radiotherapy Dosage, Cone-Beam Computed Tomography, medicine.disease, Radiation therapy, Oncology, Female, business, Nuclear medicine, Radiotherapy, Image-Guided
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::5c6f9779210fe86958451b08f8b469b2Test
https://doi.org/10.1016/j.clon.2021.10.010Test -
9دورية أكاديمية
المؤلفون: Kleijnen, Jean Paul J.E., van Asselen, Bram, Van den Begin, Robbe, Intven, Martijn, Burbach, Johannes P.M., Reerink, Onne, Philippens, Marielle E.P., de Ridder, Mark, Lagendijk, Jan J.W., Raaymakers, Bas W.
المساهمون: Ondersteuning Radiotherapie, Experimentele klinische fysica, Cancer, MS Radiotherapie, Onderzoek Radiotherapie, Fysica Radiotherapie Research
مصطلحات موضوعية: Adult, Aged, Datasets as Topic/statistics & numerical data, Dose Fractionation, Radiation, Female, Follow-Up Studies, Humans, Magnetic Resonance Imaging/methods, Male, Middle Aged, Motion, Radiotherapy Planning, Computer-Assisted/methods, Radiotherapy Setup Errors/statistics & numerical data, Radiotherapy, Adjuvant, Image-Guided/methods, Rectal Neoplasms/epidemiology, Time Factors, Tumor Burden/physiology, Journal Article
وصف الملف: image/pdf
-
10
المؤلفون: Ping Jiang, Ziyi Liu, Weijuan Jiang, Ang Qu, Haitao Sun, Junjie Wang
المصدر: Journal of applied clinical medical physics. 23(5)
مصطلحات موضوعية: Radiation, Lasers, Radiotherapy Planning, Computer-Assisted, Humans, Radiology, Nuclear Medicine and imaging, Female, Radiotherapy, Intensity-Modulated, Cone-Beam Computed Tomography, Radiotherapy Setup Errors, Mastectomy, Segmental, Instrumentation, Radiotherapy, Image-Guided
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::2acd6689452684c6bc483755a04cd360Test
https://pubmed.ncbi.nlm.nih.gov/35293667Test