Comparison of Noninvasive Measurements of Intracranial with Tap Test Results in Patients with Idiopathic Normal Pressure Hydrocephalus

التفاصيل البيبلوغرافية
العنوان: Comparison of Noninvasive Measurements of Intracranial with Tap Test Results in Patients with Idiopathic Normal Pressure Hydrocephalus
المؤلفون: Mendes GAS, Hayashi CY, Vilela GHF, Kido L, Teixeira MJ, Pinto FCG
المصدر: Neuropsychiatric Disease and Treatment, Vol Volume 19, Pp 1127-1143 (2023)
بيانات النشر: Dove Medical Press, 2023.
سنة النشر: 2023
المجموعة: LCC:Neurosciences. Biological psychiatry. Neuropsychiatry
LCC:Neurology. Diseases of the nervous system
مصطلحات موضوعية: normal pressure hydrocephalus, intracranial pressure, biomedical technology, cerebrospinal fluid pressure., Neurosciences. Biological psychiatry. Neuropsychiatry, RC321-571, Neurology. Diseases of the nervous system, RC346-429
الوصف: Gabriel André da Silva Mendes,1,2 Cintya Yukie Hayashi,2,3 Gustavo Henrique Frigieri Vilela,3 Lissa Kido,3 Manoel Jacobsen Teixeira,2 Fernando Campos Gomes Pinto2 1Physiotherapy Nucleous, Hospital of the State Public Servant of São Paulo, São Paulo City, São Paulo State, Brazil; 2Brain Hydrodynamics Group, Department of Neurosurgery, Hospital das Clínicas, University of São Paulo, São Paulo City, São Paulo State, Brazil; 3Braincare Desenvolvimento e Inovação Tecnológica S.A, São Carlos City, São Paulo State, BrazilCorrespondence: Gabriel André da Silva Mendes, Email mendes1986@yahoo.com.brBackground: Normal pressure hydrocephalus is a disease directly related to the change in intracranial compliance and consequent repercussions in the brain parenchyma. Invasive monitoring of such parameters proves to be reliable especially for prognosis in neurocritical patients; however, it is not applicable in an outpatient service setting. The present study describes the comparison between the tap test results and the parameters obtained with a non-invasive sensor for monitoring intracranial compliance in patients with suspected NPH.Methods: Twenty-eight patients were evaluated before and after lumbar puncture of 50mL of CSF (the tap test), comprising clinical assessment, magnetic resonance imaging, physical therapy assessment using the Timed Up and Go test, Dynamic Gait Index, BERG test, neuropsychological assessment, and recording of non-invasive intracranial compliance data using the Brain4care® device in three different positions (lying, sitting, and standing) for 5 min each. The tap test results were compared to the Time to Peak and P2/P1 ratio parameters obtained by the device.Results: The group that had a positive Tap test result presented a median P2/P1 ratio greater than 1.0, suggesting a change in intracranial compliance. In addition, there was also a significant difference between patients with positive, negative, and inconclusive results, especially in the lying position.Conclusion: A non-invasive intracranial compliance device when used with the patient lying down and standing up obtained parameters that suggest correspondence with the result of the tap test.Keywords: normal pressure hydrocephalus, intracranial pressure, biomedical technology, cerebrospinal fluid pressure
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1178-2021
العلاقة: https://www.dovepress.com/comparison-of-noninvasive-measurements-of-intracranial-with-tap-test-r-peer-reviewed-fulltext-article-NDTTest; https://doaj.org/toc/1178-2021Test
الوصول الحر: https://doaj.org/article/5e11c6fc1e4c46b2baa4376b5ba99b57Test
رقم الانضمام: edsdoj.5e11c6fc1e4c46b2baa4376b5ba99b57
قاعدة البيانات: Directory of Open Access Journals