دورية أكاديمية

Photon dose response functions for accurate skeletal dosimetry for Korean and Asian populations

التفاصيل البيبلوغرافية
العنوان: Photon dose response functions for accurate skeletal dosimetry for Korean and Asian populations
المؤلفون: Bangho Shin, Chansoo Choi, Rui Qiu, Suhyeon Kim, Hyeonil Kim, Sungho Moon, Gahee Son, Jaehyo Kim, Haegin Han, Yeon Soo Yeom, Chan Hyeong Kim
المصدر: Nuclear Engineering and Technology, Vol 56, Iss 6, Pp 2195-2207 (2024)
بيانات النشر: Elsevier, 2024.
سنة النشر: 2024
المجموعة: LCC:Nuclear engineering. Atomic power
مصطلحات موضوعية: Photon fluence-to-skeletal dose response function, Mesh-type reference Korean phantom, Red bone marrow, Bone endosteum, Monte Carlo dose calculation, Nuclear engineering. Atomic power, TK9001-9401
الوصف: To enhance skeletal dosimetry in conjunction with the adult mesh-type reference Korean phantoms (MRKPs), Korean/Asian photon fluence-to-skeletal dose response functions (DRFs) were established utilizing an updated version of micro-CT-based detailed bone models from Tsinghua University. These bone models were incorporated into the MRKPs using the parallel geometry feature of Geant4. We calculated bone-site-specific electron absorbed fractions and used them to generate DRFs, following a similar methodology employed for ICRP-116 DRFs that have been used with the ICRP reference phantoms for skeletal dosimetry. To assess dosimetric implications of the Korean/Asian DRFs, we calculated RBM and BE doses for the MRKPs exposed to photon beams in the antero-posterior direction using the Korean/Asian and ICRP-116 DRFs. For energies ≥200 keV, the Korean/Asian DRFs-based skeletal doses exhibited excellent agreement with the ICRP-116 DRFs-based skeletal doses, attributed to the existence of charged particle equilibrium across the bone site. Conversely, significant differences of up to ∼2.3 times were observed at lower energies, due to differences in the skeletal tissue distributions of bone models used to derive the Korean/Asian and ICRP-116 DRFs. The DRFs established in this study are expected to yield more accurate skeletal doses for Korean and Asian populations compared to the ICRP-116 DRFs.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1738-5733
العلاقة: http://www.sciencedirect.com/science/article/pii/S1738573324000305Test; https://doaj.org/toc/1738-5733Test
DOI: 10.1016/j.net.2024.01.029
الوصول الحر: https://doaj.org/article/c9a54b6c397c42a1b5b2424f3f37bfa0Test
رقم الانضمام: edsdoj.9a54b6c397c42a1b5b2424f3f37bfa0
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:17385733
DOI:10.1016/j.net.2024.01.029