Spurious hyperphosphataemia caused by an IgA paraprotein: a topic revisited

التفاصيل البيبلوغرافية
العنوان: Spurious hyperphosphataemia caused by an IgA paraprotein: a topic revisited
المؤلفون: David Sinclair, Helen Smith, Pamela Woodhead
المصدر: Annals of clinical biochemistry. 41(Pt 2)
سنة النشر: 2004
مصطلحات موضوعية: Immunoglobulin A, Clinical Biochemistry, Biochemistry, Sensitivity and Specificity, Phosphates, immune system diseases, Predictive Value of Tests, Reference Values, hemic and lymphatic diseases, medicine, Humans, cardiovascular diseases, Multiple myeloma, biology, Chemistry, Reproducibility of Results, General Medicine, medicine.disease, Serum samples, Reference values, Immunoglobulin G, Immunology, Calibration, biology.protein, Paraproteins, Multiple Myeloma
الوصف: Background: There are reports in the literature describing artefactually raised phosphate concentrations in serum samples of patients with myeloma. However, IgA paraproteins have been reported only rarely as a potential cause. Methods: Following the detection of a grossly elevated phosphate concentration in a patient with an IgA paraprotein and another with an IgG paraprotein, we estimated phosphate concentrations in a further 73 patients with paraproteins using the Bayer ADVIA 1650 and Ortho Vitros 950 analysers. The latter method has been reported to be unaffected by pseudohyperphosphataemia. Results: Deproteinization of the serum samples containing the IgA and IgG paraproteins showed that they were responsible for the interference. No significant difference in serum phosphate concentrations measured by the two analysers was noted for the larger study of serum IgG or IgM paraproteins. However, a statistically significant but clinically trivial difference in phosphate concentration was noted for serum IgA paraproteins, with the Ortho Vitros 950 giving slightly higher phosphate concentrations. Deproteinization of these samples yielded similar phosphate concentrations. Phosphate estimation in serum samples without paraproteins using both analysers yielded results that were not statistically different. Conclusion: On occasion, serum samples containing IgA paraproteins may give rise to erroneous phosphate concentrations when the Bayer ADVIA is used
تدمد: 0004-5632
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::0f057ecba368e0d39459039cdc6a73bfTest
https://pubmed.ncbi.nlm.nih.gov/15025801Test
حقوق: CLOSED
رقم الانضمام: edsair.doi.dedup.....0f057ecba368e0d39459039cdc6a73bf
قاعدة البيانات: OpenAIRE