Gross Taper Failure and Fracture of the True Neck in Total Hip Arthroplasty: Retrieval Scanning Electron Microscope Analysis

التفاصيل البيبلوغرافية
العنوان: Gross Taper Failure and Fracture of the True Neck in Total Hip Arthroplasty: Retrieval Scanning Electron Microscope Analysis
المؤلفون: Corrado Ciatti, Michelangelo Moschella, Edoardo Bori, Carlo Doria, Gianfilippo Caggiari, Bernardo Innocenti, Francesco Pisanu
المصدر: Medicina, Vol 60, Iss 3, p 458 (2024)
بيانات النشر: MDPI AG, 2024.
سنة النشر: 2024
المجموعة: LCC:Medicine (General)
مصطلحات موضوعية: metallosis, gross trunnion fracture, Morse cone, SEM analysis, mechanically assisted crevice corrosion, revision surgery, Medicine (General), R5-920
الوصف: Background and objectives: wear and corrosion can lead to the gross failure of the Morse taper junction with the consequent fracture of the true neck of the prosthetic stem in hip arthroplasty. Materials and Methods: 58-year-old male patient, with a BMI of 38 kg/m2. Because of avascular necrosis, in 2007, a metal-on-metal total hip arthroplasty was implanted in him, with a TMZF stem and a Co-Cr head. In December 2020, he complained of acute left hip pain associated with the deterioration of his left leg and total functional impairment, preceded by the crunching of the hip. X-rays and CT scan showed a fracture of the prosthetic neck that necessitated prosthetic revision surgery. A Scanning Electron Microscope (SEM) analysis of the retrieved prosthetic components was conducted. Results: Macroscopically, the trunnion showed a typical bird beak appearance, due to a massive material loss of about half of its volume. The gross material loss apparently due to abrasion extended beyond the trunnion to the point of failure on the true neck about half a centimeter distal from the taper. SEM analysis demonstrated fatigue rupture modes, and the crack began close to the neck’s surface. On the lateral surface, several scratches were found, suggesting an intense wear that could be due to abrasion. Conclusions: The analysis we conducted on the explanted THA showed a ductile rupture, began close to the upper surface of the prosthetic neck where the presence of many scratches had concentrated stresses and led to a fatigue fracture.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1648-9144
1010-660X
العلاقة: https://www.mdpi.com/1648-9144/60/3/458Test; https://doaj.org/toc/1010-660XTest; https://doaj.org/toc/1648-9144Test
DOI: 10.3390/medicina60030458
الوصول الحر: https://doaj.org/article/a13ae3caf7594688826202c71565dbd0Test
رقم الانضمام: edsdoj.13ae3caf7594688826202c71565dbd0
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:16489144
1010660X
DOI:10.3390/medicina60030458