دورية أكاديمية

Complement and Non-Complement Binding Anti-HLA Antibodies Are Differentially Detected with Different Antigen Bead Assays in Renal Transplant Recipients

التفاصيل البيبلوغرافية
العنوان: Complement and Non-Complement Binding Anti-HLA Antibodies Are Differentially Detected with Different Antigen Bead Assays in Renal Transplant Recipients
المؤلفون: Konstantinos Ouranos, Manolis Panteli, Georgios Petasis, Marianthi Papachristou, Artemis Maria Iosifidou, Myrto Aikaterini Iosifidou, Aikaterini Anastasiou, Margarita Samali, Maria Stangou, Ioannis Theodorou, Georgios Lioulios, Asimina Fylaktou
المصدر: Journal of Clinical Medicine, Vol 12, Iss 24, p 7733 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Medicine
مصطلحات موضوعية: anti-HLA antibodies, transplant, complement binding, Immucor, One-Lambda, Luminex, Medicine
الوصف: Two semi-quantitative, Luminex-based, single-antigen bead (SAB) assays are available to detect anti-HLA antibodies and evaluate their reactivity with complement binding. Sera from 97 patients with positive panel reactive antibody tests (>5%) were analyzed with two SAB tests, Immucor (IC) and One-Lambda (OL), for anti-HLA antibody detection and the evaluation of their complement-binding capacity. IC detected 1608/8148 (mean fluorescent intensity (MFI) 4195 (1995–11,272)) and 1136/7275 (MFI 6706 (2647–13,184)) positive anti-HLA class I and II specificities, respectively. Accordingly, OL detected 1942/8148 (MFI 6185 (2855–12,099)) and 1247/7275 (MFI 9498 (3630–17,702)) positive anti-HLA class I and II specificities, respectively. For the IC assay, 428/1608 (MFI 13,900 (9540–17,999)) and 409/1136 (MFI 11,832 (7128–16,531)) positive class I and II specificities bound C3d, respectively. Similarly, OL detected 485/1942 (MFI 15,452 (9369–23,095)) and 298/1247 (MFI18,852 (14,415–24,707)) C1q-binding class I and II specificities. OL was more sensitive in detecting class I and II anti-HLA antibodies than IC was, although there was no significant difference in the number of class II specificities per case. MFI was higher for complement vs. non-complement-binding anti-HLA antibodies in both assays. Both methods were equal in detecting complement-binding anti-HLA class I antibodies, whereas the C3d assay was more sensitive in detecting complement-binding anti-HLA class II antibodies.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2077-0383
العلاقة: https://www.mdpi.com/2077-0383/12/24/7733Test; https://doaj.org/toc/2077-0383Test
DOI: 10.3390/jcm12247733
الوصول الحر: https://doaj.org/article/c3dfa10a10884330993ed0b5f822f63dTest
رقم الانضمام: edsdoj.3dfa10a10884330993ed0b5f822f63d
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20770383
DOI:10.3390/jcm12247733