Accuracy of Flash Glucose Monitoring in Patients with Diabetes Mellitus on Hemodialysis and Its Relationship with Hydration Status

التفاصيل البيبلوغرافية
العنوان: Accuracy of Flash Glucose Monitoring in Patients with Diabetes Mellitus on Hemodialysis and Its Relationship with Hydration Status
المؤلفون: Ana Chico, Juan Manuel Díaz, Esther Martinez, Idoia Genua, Jaume Places, Joan Sánchez-Hernández, María José Martínez, Isabel Pujol, Carmen González
المصدر: J Diabetes Sci Technol
بيانات النشر: SAGE Publications, 2020.
سنة النشر: 2020
مصطلحات موضوعية: Blood Glucose, medicine.medical_specialty, Endocrinology, Diabetes and Metabolism, medicine.medical_treatment, Biomedical Engineering, Bioengineering, Flash (photography), Quality of life, Renal Dialysis, Diabetes mellitus, Internal medicine, Internal Medicine, medicine, Humans, In patient, Prospective Studies, Hydration status, business.industry, Blood Glucose Self-Monitoring, Monitoring system, Original Articles, medicine.disease, Diabetes Mellitus, Type 1, Glucose, Metabolic control analysis, Quality of Life, Hemodialysis, business
الوصف: Background: The use of flash-glucose monitoring system FreeStyle Libre (FSL) has demonstrated benefits in metabolic control and quality of life in different populations with diabetes mellitus (DM), being funded in many countries. Due to this, DM subjects on hemodialysis (HD) are using FSL despite the accuracy in this population being unclear. The aims of the present study are to assess the accuracy of FSL in DM subjects on HD, its relationship to hydration status, and patient satisfaction. Material and Methods: A prospective study in 16 patients with DM in a chronic HD program was conducted. Interstitial glucose values from FSL during a 14-day period were compared to capillary glucose measurements obtained at the same time. Hydration status was measured via bioimpedance spectroscopy. Satisfaction with FSL was obtained from an ad hoc satisfaction questionnaire. Results: A total of 766 paired interstitial and capillary glucose levels were analyzed. A correlation coefficient of 0.936 was determined and a mean absolute relative difference (MARD) value of 23%, increasing to 29% during HD. MARD was not related to hydration status. Interstitial glucose values were lower during HD (100.1 ± 17 mg/dL) than within the 12 hours after (125.1 ± 39 mg/dL; P = .012) and the days without HD (134.2 ± 32 mg/dL; P = .001). Subjects showed high satisfaction with FSL. Conclusion: The accuracy of FSL in DM patients on HD is lower than in other populations, especially during HD sessions and is not related with the hydration status. Despite this, the degree of patient satisfaction with FSL is very high.
تدمد: 1932-2968
الوصول الحر: https://explore.openaire.eu/search/publication?articleId=doi_dedup___::dba85e38a085992da091f21b8cc1000fTest
https://doi.org/10.1177/1932296820975057Test
حقوق: OPEN
رقم الانضمام: edsair.doi.dedup.....dba85e38a085992da091f21b8cc1000f
قاعدة البيانات: OpenAIRE