دورية أكاديمية

Rapid analysis of antimicrobial metabolites monoacetylphloroglucinol and 2,4-diacetylphlorogucinol using capillary zone electrophoresis

التفاصيل البيبلوغرافية
العنوان: Rapid analysis of antimicrobial metabolites monoacetylphloroglucinol and 2,4-diacetylphlorogucinol using capillary zone electrophoresis
المؤلفون: E Guihen (10000475), JD Glennon (10000478), Meabh Cullinane (9478391), F O'Gara (10000406)
سنة النشر: 2021
المجموعة: Smithsonian Institution: Digital Repository
مصطلحات موضوعية: Uncategorized, Science & Technology, Life Sciences & Biomedicine, Physical Sciences, Biochemical Research Methods, Chemistry, Analytical, Biochemistry & Molecular Biology, antibiotics, capillary zone electrophoresis, 2,4-diacetylphloroglucinol, monoacetylphloroglucinol, phloroglucinol, HUMAN PLASMA, PSEUDOMONAS, Pseudomonas fluorescens, Silicon Dioxide, Buffers, Electrophoresis, Capillary, Spectrophotometry, Ultraviolet, Hydrogen-Ion Concentration, Analytical Chemistry
الوصف: A rapid capillary electrophoretic (CE) method was developed for the determination of phloroglucinol compounds, monoacetylphloroglucinol (MAPG) and 2,4-diacetylphloroglucinol (DAPG), in microbial supernatants of Pseudomonas fluorescens F113 over a 24-h growth cycle. Prior to electrophoretic separation, solid-phase extraction of supernatant samples on octadecylsilica for the purpose of sample cleanup is recommended. The optimum electrophoretic conditions were found to be 25 mM sodium tetraborate running buffer at pH 9.3, temperature at 25°C with an applied voltage of 25 kV. The capillary was an Agilent fused-silica capillary of total length 33 cm × 50 μm inner diameter, 375 μ m outer diameter, with effective length 24.5 cm. While MAPG and DAPG were monitored at selected wavelengths in the range of 214-320 nm, analysis at 214 nm was used and a CE separation time of less than 2 min was achieved. A partial method validation study was performed in accordance with European Agency for Evaluation of Medicinal Products (EMEA) guidelines. The method displayed linearity over the investigated range of 10-200 μg/mL, with limits of detection of 1.2 μg/mL for MAPG and 1.3 μ g/mL for DAPG. © 2004 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
نوع الوثيقة: article in journal/newspaper
اللغة: unknown
العلاقة: https://figshare.com/articles/journal_contribution/Rapid_analysis_of_antimicrobial_metabolites_monoacetylphloroglucinol_and_2_4-diacetylphlorogucinol_using_capillary_zone_electrophoresis/13604615Test
DOI: 10.26181/602c4f309a55f
الإتاحة: https://doi.org/10.26181/602c4f309a55fTest
حقوق: CC BY 4.0
رقم الانضمام: edsbas.A93F55ED
قاعدة البيانات: BASE