Clinical benchmarking of a commercial software for skin dose estimation in cardiac, abdominal, and neurology interventional procedures.

التفاصيل البيبلوغرافية
العنوان: Clinical benchmarking of a commercial software for skin dose estimation in cardiac, abdominal, and neurology interventional procedures.
المؤلفون: Hadid‐Beurrier, Lama, Geryes, Bouchra Habib, Jean‐Pierre, Antonella, Gaudin, Paul‐Adrien, Feghali, Joëlle Ann
المصدر: Medical Physics; May2024, Vol. 51 Issue 5, p3687-3697, 11p
مصطلحات موضوعية: MEDIAN (Mathematics), NEUROLOGY, RADIATION measurements, ANGIOGRAPHY, INTERVENTIONAL radiology, IMAGING phantoms
مستخلص: Background: Radiation exposure from interventional radiology (IR) could lead to potential risk of skin injury in patients. Several dose monitoring software like radiation dose monitor (RDM) were developed to estimate the patient skin dose (PSD) distribution in IR. Purpose: This study benchmarked the accuracy of RDM software in estimating PSD as compared to GafChromic film baseline in‐vivo measurements on patients during cardiac, abdominal, and neurology IR procedures. Methods: The prospective study conducted in four IR departments included 81 IR procedures (25 cardiac, 31 abdominal, and 25 neurology procedures) on three angiographic systems. PSD and field geometry were measured by placing GafChromic film under the patient's back. Statistical analyses were performed to compare the software estimation and film measurement results in terms of PSD and geometric accuracy. Results: Median values of measured/calculated PSD were 1140/1005, 591/655.9, and 538/409.7 mGy for neurology, cardiac, and abdominal procedures, respectively. For all angiographic systems, the median (InterQuartile Range, IQR) difference between calculated and measured PSD was −10.2% (−21.8%–5.7%) for neurology, −4.5% (−19.5%–15.5%) for cardiac, and −21.9% (−38.7%–−3.6%) for abdominal IR procedures. These differences were not significant for all procedures (p > 0.05). Discrepancies increased up to −82% in lower dose regions where the measurement uncertainties are higher. Regarding the geometric accuracy, RDM correctly reproduced the skin dose map and estimated PSD area dimensions closely matched those registered on films with a median (IQR) difference of 0 cm (−1–0.8 cm). Conclusions: RDM is proved to be a useful solution for the estimation of PSD and skin dose distribution during abdominal, cardiac and neurology IR procedures despite a geometry phantom which is not specific to the latter type of IR procedures. [ABSTRACT FROM AUTHOR]
Copyright of Medical Physics is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index