دورية أكاديمية

MODERATED POSTER SESSION: New imaging techniques in classical scenarios: Saturday 6 December 2014, 08:30-12:30 * Location: Moderated Poster area

التفاصيل البيبلوغرافية
العنوان: MODERATED POSTER SESSION: New imaging techniques in classical scenarios: Saturday 6 December 2014, 08:30-12:30 * Location: Moderated Poster area
المؤلفون: Fukuyama, A, Takeuchi, M, Wu, V, Nagata, Y, Hayashi, A, Otani, K, Fukuda, S, Yoshitani, H, Lin, F, Otsuji, Y, Islas, F, Olmos, C, Almeria, C, Rodrigo, JL, De Agustin, A, Marcos-Alberca, P, Clavero, M, Saltijeral, A, Perez De Isla, L, Atout, W, Cairo University Hospitals- Echocardiography Unit Diagnostic U/S Centre, Maceira Gonzalez, A M, Igual, B, Cosin-Sales, J, Diago, JL, Aguilar, J, Ruvira, J, Sotillo, J, Bertella, E, Baggiano, A, Loguercio, M, Mushtaq, S, Petulla', M, Segurini, C, Conte, E, Andreini, D, Pontone, G, Tong, L, Ramalli, A, Tortoli, P, Luo, J, D'hooge, J, Galanti, G, Toncelli, L, Stefani, L, Pedri, S, Pedrizzetti, G, Kaminska-Kegel, AB, Jaroch, J, Brzezinska, BE, Kruszynska, E, Kusmierz, M, Loboz-Grudzien, K, Hagendorff, A, Stoebe, S, Tarr, A, Pfeiffer, D, Fazlinezhad, A, Fazlinezhad, AFSOON, Azimi, SARA, Vejdan Parast, MOHAMM, Hashemi Doost, AFSANE
بيانات النشر: Oxford University Press
سنة النشر: 2014
المجموعة: HighWire Press (Stanford University)
مصطلحات موضوعية: Saturday 6 December 2014
الوصف: Purpose: Although 2D strain is widely used to assess left ventricular mechanics, strain values derived from vendor specific 2D strain software are different even in the same subjects and are not interchangeable. We hypothesized that vendor-independent software will provide lower inter-vendor variability of 2D strain measurements. Methods: We acquired two sets of three apical images using 2 of 3 ultrasound machine (Philips, GE and Toshiba) in 81 healthy volunteers (GE vs. Philips in 26, Philips vs. Toshiba in 31 and GE vs. Toshiba in 24). Regional 2D longitudinal strain was measured using vendor-specific software and 2 vendor-independent software (TomTec and Epsilon) in each set of apical images. Then, global longitudinal strain (GLS) values were directly compared between vendor specific software and vendor independent software. Results: Correlation of GLS values between vendor specific software showed wide range of r values (0.23, 0.42 and 0.72) with significant bias except one comparison. Vendor independent software provided modest degree of correlation (TomTec: 0.65, 0.66 and 0.77, Epsilon: 0.64, 0.74 and 0.77) without significant bias in one and with significant bias in the other. Conclusions: Although vendor independent 2D strain software provided moderate correlation of GLS values between ultrasound images obtained from different ultrasound machine in the same subjects, relatively large limit agreement had a still major limitation. Our results suggest that the same ultrasound machine and the same 2D speckle tracking software should be used for the longitudinal analysis of strain values in the same subjects as well as cross sectional study. Comparison (Machine- Software)rbiasLOAp (bias)Philips-Philips vs. GE-GE
نوع الوثيقة: text
وصف الملف: text/html
اللغة: English
العلاقة: http://ehjcimaging.oxfordjournals.org/cgi/content/short/15/suppl_2/ii232Test; http://dx.doi.org/10.1093/ehjci/jeu266Test
DOI: 10.1093/ehjci/jeu266
الإتاحة: https://doi.org/10.1093/ehjci/jeu266Test
http://ehjcimaging.oxfordjournals.org/cgi/content/short/15/suppl_2/ii232Test
حقوق: Copyright (C) 2014, European Society of Cardiology
رقم الانضمام: edsbas.D93B50D
قاعدة البيانات: BASE