دورية أكاديمية

Robustness and Generalizability of Deep Learning Synthetic Computed Tomography for Positron Emission Tomography/Magnetic Resonance Imaging–Based Radiation Therapy Planning of Patients With Head and Neck Cancer

التفاصيل البيبلوغرافية
العنوان: Robustness and Generalizability of Deep Learning Synthetic Computed Tomography for Positron Emission Tomography/Magnetic Resonance Imaging–Based Radiation Therapy Planning of Patients With Head and Neck Cancer
المؤلفون: Anders B. Olin, MSc, PhD, Christopher Thomas, MPhys, MSc, Adam E. Hansen, MSc, PhD, Jacob H. Rasmussen, MD, PhD, Georgios Krokos, MSc, PhD, Teresa Guerrero Urbano, PhD, FRCR, MRCPI, LMS, Andriana Michaelidou, MBBS, MSc, FRCR, MD, Björn Jakoby, MSc, PhD, Claes N. Ladefoged, MSc, PhD, Anne K. Berthelsen, MD, Katrin Håkansson, MSc, PhD, Ivan R. Vogelius, MSc, PhD, DMSc, Lena Specht, MD, PhD, DMSc, Sally F. Barrington, MBBS, MSc, FRCP, FRCR, MD, Flemming L. Andersen, MSc, PhD, Barbara M. Fischer, MD, PhD, DMSc
المصدر: Advances in Radiation Oncology, Vol 6, Iss 6, Pp 100762- (2021)
بيانات النشر: Elsevier, 2021.
سنة النشر: 2021
المجموعة: LCC:Medical physics. Medical radiology. Nuclear medicine
LCC:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
مصطلحات موضوعية: Medical physics. Medical radiology. Nuclear medicine, R895-920, Neoplasms. Tumors. Oncology. Including cancer and carcinogens, RC254-282
الوصف: Purpose: Radiotherapy planning based only on positron emission tomography/magnetic resonance imaging (PET/MRI) lacks computed tomography (CT) information required for dose calculations. In this study, a previously developed deep learning model for creating synthetic CT (sCT) from MRI in patients with head and neck cancer was evaluated in 2 scenarios: (1) using an independent external dataset, and (2) using a local dataset after an update of the model related to scanner software-induced changes to the input MRI. Methods and Materials: Six patients from an external site and 17 patients from a local cohort were analyzed separately. Each patient underwent a CT and a PET/MRI with a Dixon MRI sequence over either one (external) or 2 (local) bed positions. For the external cohort, a previously developed deep learning model for deriving sCT from Dixon MRI was directly applied. For the local cohort, we adapted the model for an upgraded MRI acquisition using transfer learning and evaluated it in a leave-one-out process. The sCT mean absolute error for each patient was assessed. Radiotherapy dose plans based on sCT and CT were compared by assessing relevant absorbed dose differences in target volumes and organs at risk. Results: The MAEs were 78 ± 13 HU and 76 ± 12 HU for the external and local cohort, respectively. For the external cohort, absorbed dose differences in target volumes were within ± 2.3% and within ± 1% in 95% of the cases. Differences in organs at risk were
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2452-1094
العلاقة: http://www.sciencedirect.com/science/article/pii/S2452109421001202Test; https://doaj.org/toc/2452-1094Test
DOI: 10.1016/j.adro.2021.100762
الوصول الحر: https://doaj.org/article/9150efecbfb245fc843b7348e9d49adeTest
رقم الانضمام: edsdoj.9150efecbfb245fc843b7348e9d49ade
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:24521094
DOI:10.1016/j.adro.2021.100762