دورية أكاديمية

Research on data diagnosis method of acoustic array sensor device based on spectrogram

التفاصيل البيبلوغرافية
العنوان: Research on data diagnosis method of acoustic array sensor device based on spectrogram
المؤلفون: Xing Lei, Hang Ji, Qiang Xu, Ting Ye, Shengfu Zhang, Chengjun Huang
المصدر: Global Energy Interconnection, Vol 5, Iss 4, Pp 418-433 (2022)
بيانات النشر: KeAi Communications Co., Ltd., 2022.
سنة النشر: 2022
مصطلحات موضوعية: Acoustic array sensor device, Acoustic spectrogram, Partial discharge, Power equipment, False alarm rate, Energy conservation, TJ163.26-163.5, Energy industries. Energy policy. Fuel trade, HD9502-9502.5
الوصف: Acoustic array sensor device for partial discharge detection is widely used in power equipment inspection with the advantages of non-contact and precise positioning compared with partial discharge detection methods such as ultrasonic method and pulse current method. However, due to the sensitivity of the acoustic array sensor and the influence of the equipment operation site interference, the acoustic array sensor device for partial discharge type diagnosis by phase resolved partial discharge (PRPD) map might occasionally presents incorrect results, thus affecting the power equipment operation and maintenance strategy. The acoustic array sensor detection device for power equipment developed in this paper applies the array design model of equal-area multi-arm spiral with machine learning fast fourier transform clean (FFT-CLEAN) sound source localization identification algorithm to avoid the interference factors in the noise acquisition system using a single microphone and conventional beam forming algorithm, improves the spatial resolution of the acoustic array sensor device, and proposes an acoustic array sensor device based on the acoustic spectrogram. The analysis and diagnosis method of discharge type of acoustic array sensor device can effectively reduce the system misjudgment caused by factors such as the resolution of the acoustic imaging device and the time domain pulse of the digital signal, and reduce the false alarm rate of the acoustic array sensor device. The proposed method is tested by selecting power cables as the object, and its effectiveness is proved by laboratory verification and field verification.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2096-5117
العلاقة: http://www.sciencedirect.com/science/article/pii/S2096511722000810Test; https://doaj.org/toc/2096-5117Test
DOI: 10.1016/j.gloei.2022.08.008
الوصول الحر: https://doaj.org/article/950604178eb8478084d5c5e26e4c75fdTest
رقم الانضمام: edsdoj.950604178eb8478084d5c5e26e4c75fd
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20965117
DOI:10.1016/j.gloei.2022.08.008