دورية أكاديمية

Finite Element Analysis of Femoral-Acetabular Impingement (FAI) Based on Three-Dimensional Reconstruction.

التفاصيل البيبلوغرافية
العنوان: Finite Element Analysis of Femoral-Acetabular Impingement (FAI) Based on Three-Dimensional Reconstruction.
المؤلفون: Luo, Xi, Zhang, Jun, Cai, Guofeng, Wu, Yuqiong, Ma, Kun
المصدر: Journal of Healthcare Engineering; 2/27/2022, p1-13, 13p
مصطلحات موضوعية: FINITE element method, HIP joint, IMAGE registration, RANGE of motion of joints
مستخلص: In order to solve the problem that people often have pain in the hip joint, it is more meaningful to study femoral-acetabular impingement syndrome in the future. This article aims to study the finite element analysis of femoral-acetabular impingement based on three-dimensional reconstruction. This paper proposes a selective image matching strategy. In the feature matching stage, all images are not matched in pairs, but the corresponding camera distance between the images is calculated initially, which has little effect on the number of features and greatly reduces the time of feature matching, thereby reducing the time cost of 3D reconstruction. In this experiment, a double-blind experiment was used to check the range of motion of all hip joints. Two senior radiologists read the obtained hip joint orthographic films to screen out the hip joint orthographic films that meet the requirements. Experimental data shows that although the initial matching points of the algorithm in this paper are lower than those of the traditional algorithm, the final number of matching points is higher than that of the traditional algorithm. When the final number of patches is fixed to 10000, the initial patch required by the algorithm in this paper is more than that required by the SAD algorithm, nearly 13%, but the total storage requirement is 56.4% of the SAD algorithm, which is a big improvement. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Healthcare Engineering is the property of Hindawi Limited and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:20402295
DOI:10.1155/2022/2937056