Scanning electron microscopy analysis of aligner fitting on anchorage attachments.

التفاصيل البيبلوغرافية
العنوان: Scanning electron microscopy analysis of aligner fitting on anchorage attachments.
العنوان البديل: Rasterelektronenmikroskopische Untersuchung der Paßgenauigkeit von Alignern an Verankerungsattachments. (German)
المؤلفون: Mantovani, Edoardo, Castroflorio, Enrico, Rossini, Gabriele, Garino, Francesco, Cugliari, Giovanni, Deregibus, Andrea, Castroflorio, Tommaso
المصدر: Journal of Orofacial Orthopedics/Fortschritte der Kieferorthopadie; Mar2019, Vol. 80 Issue 2, p79-87, 9p
مصطلحات موضوعية: SCANNING electron microscopy
مصطلحات جغرافية: ITALY, SWEDEN, UNITED States
مستخلص: Purpose: The aims of the study were (1) to evaluate the fitting of three different aligners (Invisalign [Align Technology, Santa Clara, CA, USA], CA Clear Aligner [Scheu-Dental, Iserlohn, Germany] and F22 [Sweden&Martina, Due Carrare, Italy]) on anchorage attachments using scanning electron microscopy (SEM), and (2) to analyze the influence of 2 different types of resin used to build attachments on aligner fitting.Methods: Using STL files of a patient, six resin casts were obtained and rectangular attachments were bonded on them. Conventional bulk-fill resin was used to build upper attachments while a flowable resin was used to build the lower ones. Passive aligners were adapted on each cast and then sectioned buccolingually. Microphotographs of the obtained sections were performed using a SEM and then micrometric measurements of aligner fitting on anchorage attachments were recorded.Results: Analyzing the overall fitting of upper arch aligners, Invisalign provided a significantly better fitting with respect to F22 (P = 0.009); differences were not significant when comparing Invisalign with CA Clear Aligner, and CA Clear Aligner with F22. Analyzing the overall fitting of lower arch aligners, F22 provided a significantly better fitting with respect to CA Clear Aligner (P = 0.008) and Invisalign (P = 0.011). The analysis showed a significantly better fitting on upper attachments, built using conventional bulk-fill resin (P = 0.034).Conclusions: Invisalign, CA Clear Aligner and F22 have comparable performance in terms of fitting on anchorage attachments. Conventional bulk-fill resin provides the best fitting on anchorage attachments. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Orofacial Orthopedics/Fortschritte der Kieferorthopadie is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)