Efficacy of Non-contact BallistocardiographySystem to Determine Heart Rate Variability.

التفاصيل البيبلوغرافية
العنوان: Efficacy of Non-contact BallistocardiographySystem to Determine Heart Rate Variability.
المؤلفون: Parchani, Gaurav, Kumar, Gulshan, Rao, Raghavendra, Udupa, Kaviraja, Saran, Vibhor
المصدر: Annals of Neurosciences; Jan2022, Vol. 29 Issue 1, p16-20, 5p
مصطلحات موضوعية: HEART beat, AUTONOMIC nervous system, CHRONIC kidney failure, ROOT-mean-squares, RANK correlation (Statistics)
مصطلحات جغرافية: KENDALL (Fla.)
مستخلص: Background: Functions of the autonomic nervous system have cardinal importance in day-to-day life. Heart rate variability (HRV) has been shown to estimate the functioning of the autonomic nervous system. Imbalance in the functioning of the autonomic nervous system is seen to be associated with chronic conditions such as chronic kidney disease, cardiovascular diseases, diabetes mellitus, and so on. Purpose: To evaluate the efficacy of a non-contact ballistocardiography (BCG) system to calculate HRV parameters by comparing them to the parameters derived from a standard commercial software that uses an electrocardiogram (ECG). Methods: Current study captured an ECG signal using a three-channel ECG Holter machine, whereas the BCG signal was captured using a BCG sensor sheet consisting of vibroacoustic sensors placed under the mattress of the participants of the study. Results: The study was conducted on 24 subjects for a total of 54 overnight recordings. The proposed method covered 97.92% epochs of the standard deviation of NN intervals (SDNN) and 99.27% epochs of root mean square of successive differences (RMSSD) within 20 ms and 30 ms tolerance, respectively, whereas 98.84% of two-min intervals for low-frequency (LF) to high-frequency (HF) ratio was covered within a tolerance of 1. Kendall's coefficient of concordance was also calculated, giving a P <.001 for all the three parameters and coefficients 0.66, 0.55, and 0.44 for SDNN, RMSSD, and LF/HF, respectively. Conclusion: The results show that HRV parameters captured using unobtrusive and non-invasive BCG sensors are comparable to HRV calculated using ECG. [ABSTRACT FROM AUTHOR]
Copyright of Annals of Neurosciences is the property of Indian Academy of Neurosciences and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:09727531
DOI:10.1177/09727531211063426