دورية أكاديمية

Initial in vivo PET imaging of 5-HT1A receptors with 3-[(18)F]mefway.

التفاصيل البيبلوغرافية
العنوان: Initial in vivo PET imaging of 5-HT1A receptors with 3-[(18)F]mefway.
المؤلفون: Wooten, Dustin W, Hillmer, Ansel T, Murali, Dhanabalan, Barnhart, Todd E, Thio, Joanne P, Bajwa, Alisha K, Bonab, Ali A, Normandin, Marc D, Schneider, Mary L, Mukherjee, Jogeshwar, Christian, Bradley T
المصدر: Am j nucl med mol imaging, vol 4, iss 5
بيانات النشر: eScholarship, University of California
سنة النشر: 2014
المجموعة: University of California: eScholarship
مصطلحات موضوعية: Biological Psychology, Biomedical and Clinical Sciences, Psychology, Biomedical Imaging, 5-HT1A, PET, serotonin, mefway
جغرافية الموضوع: 483 - 489
الوصف: 4-trans-[(18)F]Mefway is a PET radiotracer with high affinity for 5-HT1A receptors. Our preliminary work indicated the positional isomer, 3-[(18)F]mefway, would be suitable for PET imaging of 5-HT1A receptors. We now compare the in vivo behaviour of 3-mefway with 4-mefway to evaluate 3-[(18)F]mefway as a potential 5-HT1A PET radiotracer. Two male rhesus macaques were given bolus injections of both 3- and 4-trans-[(18)F]mefway in separate experiments. 90 minute dynamic PET scans were acquired. TACs were extracted in the mesial temporal lobe (MTL) and caudal anterior cingulate gyrus (cACg). The cerebellum (CB) was used as a reference region. In vivo behavior of the radiotracers in the CB was compared based upon the ratio of normalized PET uptake for 3- and 4-trans-[(18)F]mefway. Specific binding was compared by examining MTL/CB and cACg/CB ratios. The subject-averaged ratio of 3-[(18)F]mefway to 4-trans-[(18)F]mefway in the cerebellum was 0.96 for 60-90 minutes. MTL/CB reached plateaus of ~2.7 and ~6 by 40 minutes and 90 minutes for 3- and 4-trans-[(18)F]mefway, respectively. cACg/CB reached plateaus of ~2.5 and ~6 by 40 minutes and 70 minutes for 3- and 4-trans-[(18)F]mefway, respectively. The short pseudoequilibration times and sufficient uptake of 3-[(18)F]mefway may be useful in studies requiring short scan times. Furthermore, the similar nondisplaceable clearance in the CB to 4-trans-[(18)F]mefway suggests the lower BPND of 3-[(18)F]mefway is due to a lower affinity. The lower affinity of 3-[(18)F]mefway may make it useful for measuring changes in endogenous 5-HT levels, however, this remains to be ascertained.
نوع الوثيقة: article in journal/newspaper
وصف الملف: application/pdf
اللغة: unknown
العلاقة: qt36g9x70d; https://escholarship.org/uc/item/36g9x70dTest
الإتاحة: https://escholarship.org/uc/item/36g9x70dTest
حقوق: public
رقم الانضمام: edsbas.41F1AFD4
قاعدة البيانات: BASE