Gated thoracic magnetic resonance angiography at 3T: noncontrast versus blood pool contrast

التفاصيل البيبلوغرافية
العنوان: Gated thoracic magnetic resonance angiography at 3T: noncontrast versus blood pool contrast
المؤلفون: Zhu, Chengcheng, Haraldsson, Henrik, Kallianos, Kimberly, Ge, Liang, Tseng, Elaine, Henry, Travis, Saloner, David, Hope, Michael D
المصدر: The International Journal of Cardiovascular Imaging, vol 34, iss 3
بيانات النشر: eScholarship, University of California
سنة النشر: 2018
المجموعة: University of California: eScholarship
مصطلحات موضوعية: Biomedical and Clinical Sciences, Cardiovascular Medicine and Haematology, Clinical Sciences, Cardiovascular, Clinical Trials and Supportive Activities, Biomedical Imaging, Clinical Research, Aged, 80 and over, Aorta, Thoracic, Aortic Valve, Aortography, Cardiac-Gated Imaging Techniques, Contrast Media, Electrocardiography, Female, Ferrosoferric Oxide, Humans, Magnetic Resonance Angiography, Male, Middle Aged, Observer Variation, Predictive Value of Tests, Reproducibility of Results, Retrospective Studies, MRA, TAVR, Contrast, Measurement reproducibility
جغرافية الموضوع: 475 - 483
الوصف: Both noncontrast and contrast-enhanced approaches to gated thoracic magnetic resonance angiography (MRA) for aortic root evaluation have been reported at 3T. We compare qualitative and quantitative image quality measures for the two approaches, and assess the reproducibility of standard aortic measurements. Respiratory and cardiac gated MRA of the chest was performed at 3T in 45 patients: 23 after administration of iron-based blood pool contrast, and 22 without contrast. Image quality was assessed with a 5-point Likert scale, vessel lumen-to-muscle contrast ratios, and vessel wall sharpness. Two reviewers measured the ascending aorta diameter and valve annulus area. Interrater agreement was assessed using Bland-Altman plots and coefficient of variation (CV). Qualitative image quality was better with blood pool contrast in all principal vessels of the chest (mean Likert of 4.20 ± 0.79 vs. 2.60 ± 0.77, p < 0.001). Quantitative assessment was also improved with higher contrast ratios in all vessels (5.26 ± 3.3 vs. 1.90 ± 0.53, p < 0.001), and greater sharpness of the aortic annulus and ascending aorta (0.70 ± 0.16 vs. 0.56 ± 0.14mm-1, p < 0.001, and 0.87 ± 0.16 vs. 0.62 ± 0.16mm-1, p = 0.008, respectively). Reproducibility of measurement was marginally better for the ascending aorta diameter (CV of 2.80 vs. 3.23%), but substantially increased for the aortic valve annulus area with blood pool contrast (CV of 4.93 vs. 7.32%). The use of a blood pool contrast agent for gated thoracic MRA improves image quality compared to a noncontrast technique, and provides more reproducible measurements of the aortic valve annulus area.
نوع الوثيقة: article in journal/newspaper
وصف الملف: application/pdf
اللغة: unknown
العلاقة: qt0td198bx; https://escholarship.org/uc/item/0td198bxTest
الإتاحة: https://escholarship.org/uc/item/0td198bxTest
حقوق: public
رقم الانضمام: edsbas.1E76EEF4
قاعدة البيانات: BASE