دورية أكاديمية

Validation of OMPS Suomi NPP and OMPS NOAA‐20 Formaldehyde Total Columns With NDACC FTIR Observations

التفاصيل البيبلوغرافية
العنوان: Validation of OMPS Suomi NPP and OMPS NOAA‐20 Formaldehyde Total Columns With NDACC FTIR Observations
المؤلفون: H.‐A. Kwon, G. González Abad, C. R. Nowlan, H. Chong, A. H. Souri, C. Vigouroux, A. Röhling, R. Kivi, M. Makarova, J. Notholt, M. Palm, H. Winkler, Y. Té, R. Sussmann, M. Rettinger, E. Mahieu, K. Strong, E. Lutsch, S. Yamanouchi, T. Nagahama, J. W. Hannigan, M. Zhou, I. Murata, M. Grutter, W. Stremme, M. DeMazière, N. Jones, D. Smale, I. Morino
المصدر: Earth and Space Science, Vol 10, Iss 5, Pp n/a-n/a (2023)
بيانات النشر: American Geophysical Union (AGU), 2023.
سنة النشر: 2023
المجموعة: LCC:Astronomy
LCC:Geology
مصطلحات موضوعية: formaldehyde, OMPS, Suomi NPP, NOAA‐20, FTIR, validation, Astronomy, QB1-991, Geology, QE1-996.5
الوصف: Abstract We validate formaldehyde (HCHO) vertical column densities (VCDs) from Ozone Mapping and Profiler Suite Nadir Mapper (OMPS‐NM) instruments onboard the Suomi National Polar‐orbiting Partnership (Suomi NPP) satellite for 2012–2020 and National Oceanic and Atmospheric Administration‐20 (NOAA‐20) satellite for 2018–2020, hereafter referred to as OMPS‐NPP and OMPS‐N20, with ground‐based Fourier‐Transform Infrared (FTIR) observations of the Network for the Detection of Atmospheric Composition Change (NDACC). OMPS‐NPP/N20 HCHO products reproduce seasonal variability at 24 FTIR sites. Monthly variability of OMPS‐NPP/N20 has a very good agreement with FTIR, showing correlation coefficients of 0.83 and 0.88, respectively. OMPS‐NPP (N20) biases averaged over all sites are −0.9 (4) ± 3 (6)%. However, at clean sites (with VCDs 4.0 × 1015 molecules cm−2, negative biases of −15% ± 4% appear for OMPS‐NPP, but OMPS‐N20 shows smaller bias of 0.5% ± 6% due to its smaller ground pixel footprints. Therefore, smaller satellite footprint sizes are important in distinguishing small‐scale plumes. In addition, we discuss a bias correction and provide lower limit for the monthly uncertainty of OMPS‐NPP/N20 HCHO products. The total uncertainty for OMPS‐NPP (N20) at clean sites is 0.7 (0.8) × 1015 molecules cm−2, corresponding to a relative uncertainty of 32 (30)%. In the case of HCHO VCDs > 4.0 × 1015 molecules cm−2, however, the relative uncertainty in HCHO VCDs for OMPS‐NPP (N20) decreases to 31 (18)%.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2333-5084
العلاقة: https://doaj.org/toc/2333-5084Test
DOI: 10.1029/2022EA002778
الوصول الحر: https://doaj.org/article/66ede90bf2fe4c62b5c1b35f36ea1f33Test
رقم الانضمام: edsdoj.66ede90bf2fe4c62b5c1b35f36ea1f33
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:23335084
DOI:10.1029/2022EA002778