In vitro, in vivo, and clinical tests of a novel flexible ureteroscope for the diagnosis and treatment of kidney and ureteral diseases
العنوان: | In vitro, in vivo, and clinical tests of a novel flexible ureteroscope for the diagnosis and treatment of kidney and ureteral diseases |
---|---|
المؤلفون: | Dai Hee Kim, Jung Hyun Shin, Se Young Choi, Dalsan You, Choung-Soo Kim, Hyung Keun Park |
المصدر: | Investigative and Clinical Urology, Vol 59, Iss 5, Pp 328-334 (2018) |
بيانات النشر: | Korean Urological Association, 2018. |
سنة النشر: | 2018 |
المجموعة: | LCC:Diseases of the genitourinary system. Urology |
مصطلحات موضوعية: | Lithotripsy, Nephrolithiasis, Ureteroscopes, Diseases of the genitourinary system. Urology, RC870-923 |
الوصف: | Purpose: Despite advances in flexible ureteroscopy, the high cost and long repair time of ureteroscopes limit their use in the urology. We compared the performance of a novel flexible ureteroscope (fURS) ‘HF-EH’ with that of the two contemporary fURSs ‘URF-P6’ and ‘COBRA’. Materials and Methods: We compared in vitro measurements of deflection angle, irrigation flow rate, and image quality between HF-EH and URF-P6 while also inspecting renal collecting systems in five female pigs. For clinical testing, we performed retrograde intrarenal surgeries using HF-EH in four patients. Experienced urologists compared performance parameters (irrigation, convenience, and maneuverability) between the HF-EH and COBRA. Results: The flow rate of HF-EH (21.0 mL/min) was worse, and its resolution (1.59 line pairs/mm) was inferior to that of URF-P6 (28.7 mL/min and 3.17 line pairs/mm, respectively). However, HF-EH was superior to URF-P6 in terms of loss of deflection angle with the insertion of accessories (1.8% vs. 12.7%). In vivo and clinical testing revealed that the performance parameters of HF-EH were slightly inferior to those of conventional domestic fURSs. We successfully performed retrograde intrarenal surgeries using HF-EH in four patients and achieved stone-free statuses in two. None of the patients exhibited any procedure-related complications. Conclusions: Although we observed that two of the three performance parameters of the novel ureteroscope ‘HF-EH’ were inferior to those of the conventional ureteroscope, we successfully used HF-EH to perform retrograde intrarenal surgeries in patients. Further studies on performance and durability are warranted for making HF-EH commercially available. |
نوع الوثيقة: | article |
وصف الملف: | electronic resource |
اللغة: | English |
تدمد: | 2466-0493 2466-054X |
العلاقة: | https://www.icurology.org/Synapse/Data/PDFData/2020ICU/icu-59-328.pdfTest; https://doaj.org/toc/2466-0493Test; https://doaj.org/toc/2466-054XTest |
DOI: | 10.4111/icu.2018.59.5.328 |
الوصول الحر: | https://doaj.org/article/afb923c99ab24e458f9f217b05efa94eTest |
رقم الانضمام: | edsdoj.fb923c99ab24e458f9f217b05efa94e |
قاعدة البيانات: | Directory of Open Access Journals |
تدمد: | 24660493 2466054X |
---|---|
DOI: | 10.4111/icu.2018.59.5.328 |