دورية أكاديمية

Can imaging be the new yardstick for diagnosing peripheral neuropathy?—a comparison between high resolution ultrasound and MR neurography with an approach to diagnosis.

التفاصيل البيبلوغرافية
العنوان: Can imaging be the new yardstick for diagnosing peripheral neuropathy?—a comparison between high resolution ultrasound and MR neurography with an approach to diagnosis.
المؤلفون: Agarwal, Aakanksha, Chandra, Abhishek, Jaipal, Usha, Bagarhatta, Meenu, Mendiratta, Kuldeep, Goyal, Alka, Kumar, Raghav, Mangalhara, Naresh
المصدر: Insights into Imaging; Jan2019, Vol. 10 Issue 1, p1-13, 13p
مصطلحات موضوعية: ULTRASONIC imaging, NEUROMAS, DIAGNOSIS, PERIPHERAL neuropathy, PERIPHERAL nervous system, SYMPTOMS, MAGNETIC resonance neurography
مستخلص: Purpose: Peripheral neuropathies are a group of disorders which affect the peripheral nervous system which have been conventionally diagnosed using electrodiagnostic studies. This study was carried out to assess the role of imaging in diagnosing peripheral mononeuropathy as exact anatomical localisation of the pathology is possible using high-resolution ultrasound and MR neurography, the modalities assessed in this study. Method: A hospital-based prospective analytical study was carried out in a resource-limited setting on 180 peripheral nerves in 131 patients with symptoms of peripheral mononeuropathy after taking IRB approval. Each patient underwent high-resolution ultrasound examination and MR neurography, findings of which were then compared and statistically analysed assuming electrodiagnostic findings as the gold standard. Results: Overall, the diagnostic accuracy was highest for the proton density fat-saturated MR sequence (93.89%) followed by high-resolution ultrasound (80%). The sensitivity was highest for proton density fat-saturated sequence while the T1 MR sequence had the highest specificity. Combined diagnostic accuracy of both modalities was calculated to be 93.33% with a negative predictive value of 80%. High-resolution ultrasound and MRI equally detected the cases with nerve discontinuity, while neuromas were better identified on MRI. Conclusion: With the advent of higher frequency probes and improved MR field strength, imaging of peripheral nerves is possible with better accuracy. Imaging assessment of nerves allows anatomical delineation with identification of exact site of involvement. This comparative study demonstrates the role of imaging in diagnosing peripheral nerve pathologies with the accuracy of MRI as high as 93.89% which may serve as an imaging gold standard. High-resolution ultrasound, being quicker, cost effective and a comparable accuracy of 80% can serve as a reliable screening tool. This study incorporates a larger study group and compares HRUS with MRI, taking NCV as gold standard, which has not been done in the preceding studies. With this study, we conclude that these two imaging modalities are not mutually exclusive. Rather, they complement each other and can be used in conjunction as an imaging yardstick for diagnosing peripheral neuropathies. [ABSTRACT FROM AUTHOR]
Copyright of Insights into Imaging is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:18694101
DOI:10.1186/s13244-019-0787-6