دورية أكاديمية

Comparison of three commonly used CT perfusion software packages in patients with acute ischemic stroke.

التفاصيل البيبلوغرافية
العنوان: Comparison of three commonly used CT perfusion software packages in patients with acute ischemic stroke.
المؤلفون: Koopman, Miou S., Berkhemer, Olvert A., Geuskens, Ralph R. E. G., Emmer, Bart J., van Walderveen, Marianne A. A., Jenniskens, Sjoerd F. M., van Zwam, Wim H., van Oostenbrugge, Robert J., van der Lugt, Aad, Dippel, Diederik W. J., Beenen, Ludo F., Roos, Yvo B. W. E. M., Marquering, Henk A., Majoie, Charles B. L. M.
المصدر: Journal of NeuroInterventional Surgery; Dec2019, Vol. 11 Issue 12, p1249-1256, 8p, 2 Diagrams, 5 Charts, 2 Graphs
مصطلحات موضوعية: CEREBRAL ischemia, COMPUTED tomography, COMPUTER software, PERFUSION, RADIONUCLIDE imaging, STROKE, DECISION making in clinical medicine, CONTRAST media, INTRACLASS correlation
مستخلص: Background and purpose CT perfusion (CTP) might support decision making in patients with acute ischemic stroke by providing perfusion maps of ischemic tissue. Currently, the reliability of CTP is hampered by varying results between different post-processing software packages. The purpose of this study is to compare ischemic core volumes estimated by IntelliSpace Portal (ISP) and syngo.via with core volumes as estimated by RAPID. Methods Thirty-five CTP datasets from patients in the MR CLEAN trial were post-processed. Core volumes were estimated with ISP using default settings and with syngo.via using three different settings: default settings (method A); additional smoothing filter (method B); and adjusted settings (method C). The results were compared with RAPID. Agreement between methods was assessed using Bland-Altman analysis and intraclass correlation coefficient (ICC). Accuracy for detecting volumes up to 25 mL, 50 mL, and 70 mL was assessed. Final infarct volumes were determined on follow-up non-contrast CT. Results Median core volume was 50 mL with ISP, 41 mL with syngo.via method A, 20 mL with method B, 36 mL with method C, and 11 mL with RAPID. Agreement ranged from poor (ISP: ICC 0.41; method A: ICC 0.23) to good (method B: ICC 0.83; method C: ICC 0.85). The bias (1.8 mL) and limits of agreement (-27, 31 mL) were the smallest with syngo.via with additional smoothing (method B). Agreement for detecting core volumes ≤25 mL with ISP was 54% and 57%, 85% and 74% for syngo.via methods A, B, and C, respectively. Conclusion Best agreement with RAPID software is provided by syngo.via default settings with additional smoothing. Moreover, this method has the highest agreement in categorizing patients with small core volumes. [ABSTRACT FROM AUTHOR]
Copyright of Journal of NeuroInterventional Surgery is the property of BMJ Publishing Group and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:17598478
DOI:10.1136/neurintsurg-2019-014822