دورية أكاديمية

Steinmann pin augmentation versus locking plate constructs.

التفاصيل البيبلوغرافية
العنوان: Steinmann pin augmentation versus locking plate constructs.
المؤلفون: Ruskin, Jeremy, Caravaggi, Paolo, Beebe, Kathleen, Corgan, Sondra, Chen, Linda, Yoon, Richard, Patterson, Francis, Hwang, John, Beebe, Kathleen S, Yoon, Richard S, Patterson, Francis R, Hwang, John S
المصدر: Journal of Orthopaedics & Traumatology; Sep2016, Vol. 17 Issue 3, p249-254, 6p
مصطلحات موضوعية: ORTHOPEDIC implants, CURETTAGE, GIANT cell tumors, TRAUMATIC bone defects, ONCOLOGY, TIBIA surgery, COMPARATIVE studies, DEAD, FRACTURE fixation, BONE fractures, RESEARCH methodology, MEDICAL cooperation, POLYMETHYLMETHACRYLATE, RESEARCH, TIBIA, EVALUATION research, TREATMENT effectiveness, IN vitro studies
مستخلص: Background: Aggressive bone neoplasms, such as giant cell tumors, often affect the proximal tibia warranting bony resection via curettage leaving behind massive defects that require extensive reconstruction. Reconstruction is usually accomplished with poly(methyl methacrylate) (PMMA) packing supplemented with an internal fixation construct. The purpose of this study is to compare Steinmann pin augmentation to locking plate constructs to determine which offers the stiffer reconstruction option.Materials and Methods: Large defects were created below the lateral condyle of fresh frozen tibias. The defects extended for an average of 35 mm beneath the lateral plateau in the frontal plane, and from the anterior to posterior cortex in the sagittal plane. Distally the defect extended for an average of 35 mm to the metadiaphyseal junction. In the Pin group, the tibias were reconstructed with three 4-mm diameter Steinmann pins placed in the medullary canal and PMMA packing. In the Plate group, the tibias were reconstructed with a 6-hole 3.5-mm LCP Proximal locking plate fixed to the proximal-lateral tibia utilizing seven 3.5-mm screws and PMMA packing. The tibias were tested for stiffness on a MTS machine by applying up to 400 N to the tibial plateau in force control at 5 N/s. Fatigue properties were tested by applying a haversine loading waveform between 200 N and 1,200 N at 3 Hz simulating walking upstairs/downstairs.Results: Locking plate constructs (801.8 ± 78 N/mm) had greater (p = 0.041) stiffness than tibial constructs fixed with Steinmann pins (646.5 ± 206.3 N/mm).Conclusions: Permanent deformation was similar between the Pin and Plate group; however, two tibia from the Pin group exhibited displacements >5 mm which we considered failure.Level Of Evidence: n/a. [ABSTRACT FROM AUTHOR]
Copyright of Journal of Orthopaedics & Traumatology is the property of Springer Nature and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Complementary Index
الوصف
تدمد:15909921
DOI:10.1007/s10195-016-0394-y