دورية أكاديمية

Novel A20-gene-eluting stent inhibits carotid artery restenosis in a porcine model

التفاصيل البيبلوغرافية
العنوان: Novel A20-gene-eluting stent inhibits carotid artery restenosis in a porcine model
المؤلفون: Zhou ZH, Peng J, Meng ZY, Chen L, Huang JL, Huang HQ, Li L, Zeng W, Wei Y, Zhu CH, Chen KN
المصدر: Drug Design, Development and Therapy, Vol 2016, Iss Issue 1, Pp 2341-2351 (2016)
بيانات النشر: Dove Medical Press, 2016.
سنة النشر: 2016
المجموعة: LCC:Therapeutics. Pharmacology
مصطلحات موضوعية: Restenosis, A20, Gene therapy, Stent, Endothelialization, Therapeutics. Pharmacology, RM1-950
الوصف: Zhen-hua Zhou,1 Jing Peng,1 Zhao-you Meng,1 Lin Chen,1 Jia-Lu Huang,1 He-qing Huang,1 Li Li,2 Wen Zeng,2 Yong Wei,2 Chu-Hong Zhu,2 Kang-Ning Chen1 1Department of Neurology, Cerebrovascular Disease Research Institute, Southwest Hospital, 2Department of Anatomy, Key Laboratory for Biomechanics of Chongqing, Third Military Medical University, Chongqing, People’s Republic of China Background: Carotid artery stenosis is a major risk factor for ischemic stroke. Although carotid angioplasty and stenting using an embolic protection device has been introduced as a less invasive carotid revascularization approach, in-stent restenosis limits its long-term efficacy and safety. The objective of this study was to test the anti-restenosis effects of local stent-mediated delivery of the A20 gene in a porcine carotid artery model.Materials and methods: The pCDNA3.1EHA20 was firmly attached onto stents that had been collagen coated and treated with N-succinimidyl-3-(2-pyridyldithiol)propionate solution and anti-DNA immunoglobulin fixation. Anti-restenosis effects of modified vs control (the bare-metal stent and pCDNA3.1 void vector) stents were assessed by Western blot and scanning electron microscopy, as well as by morphological and inflammatory reaction analyses.Results: Stent-delivered A20 gene was locally expressed in porcine carotids in association with significantly greater extent of re-endothelialization at day 14 and of neointimal hyperplasia inhibition at 3 months than stenting without A20 gene expression.Conclusion: The A20-gene-eluting stent inhibits neointimal hyperplasia while promoting re-endothelialization and therefore constitutes a novel potential alternative to prevent restenosis while minimizing complications. Keywords: restenosis, A20, gene therapy, stent, endothelialization
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1177-8881
العلاقة: https://www.dovepress.com/novel-a20-gene-eluting-stent-inhibits-carotid-artery-restenosis-in-a-p-peer-reviewed-article-DDDTTest; https://doaj.org/toc/1177-8881Test
الوصول الحر: https://doaj.org/article/119027fa2aa4450c86232b5052683b0fTest
رقم الانضمام: edsdoj.119027fa2aa4450c86232b5052683b0f
قاعدة البيانات: Directory of Open Access Journals