دورية أكاديمية

Detection of gastrointestinal and abdominal infections by, Tc-99m-ciprofloxacin

التفاصيل البيبلوغرافية
العنوان: Detection of gastrointestinal and abdominal infections by, Tc-99m-ciprofloxacin
المؤلفون: Artiko, V, Davidovic, B, Nikolic, N, Petrović, M, Vlajkovic, M, Pesko, P, Knežević, S., Dukić, V, Stefanovic, B, Tulic, C, Popovic, N, Milosavljevic, T, Obradović, V
المصدر: Hepato-gastroenterology
سنة النشر: 2005
المجموعة: VinaR Repository (Vinča Institute of Nuclear Sciences / University of Belgrade)
مصطلحات موضوعية: 99mTc-ciprofloxacin, abdomen, gastrointestinal, infection
الوصف: Background/Aims: The aim of the study is detection and evaluation of the abdominal and gastrointestinal; infective foci using Tc-99m-ciprofloxacin (Laboratory for radioactive isotopes, Vinca). Methodology: In total 21 patients with clinical suspicion on abdominal or gastrointestinal infection were investigated. In all the patients, planar liver/spleen scintigraphy was performed. Ciprofloxacin chloride (3.5mg) was mixed with 555MBq of Tc-99m in 3mL of physiological solution and incubated for 20 min. After slow i.v. injection in a cubital vein, dynamic acquisition (1 f/min) was performed during the first 60 min in the position of interest, followed by static acquisition (500 000 imp) anterior and posterior view, abdomen and pelvis after 1 h and 4 h in all patients. When necessary, additional scintigrams were acquired after 24h. In all the patients with negative or equivocal findings of planar scintigraphy, emission computerized tomography (SPECT) was performed (60 positions, 6 degrees). Interpretation was made by three independent observers. Additional data were provided using clinical findings, ultrasonography, computed tomography and magnetic resonance imaging, laboratory analyses, and surgical or microbiological confirmation of infection. Results: There were eleven true-positive findings, seven true negative, two were false negative while one was false positive due to intestinal obstruction. Sensitivity was 79%, specificity 91%, positive predictive value 92%, negative predictive value 77% accuracy 84%. Conclusions: According to our results, scintigraphy with radiolabeled ciprofloxacin is a useful method for detection and assessment of exact localization of abdominal and gastrointestinal infections.
نوع الوثيقة: article in journal/newspaper
اللغة: unknown
تدمد: 0172-6390
العلاقة: https://vinar.vin.bg.ac.rs/handle/123456789/2874Test; 000227976800037; https://hdl.handle.net/21.15107/rcub_vinar_2874Test
الإتاحة: https://vinar.vin.bg.ac.rs/handle/123456789/2874Test
https://hdl.handle.net/21.15107/rcub_vinar_2874Test
حقوق: restrictedAccess
رقم الانضمام: edsbas.71F13C55
قاعدة البيانات: BASE