دورية أكاديمية

Non-Ventilator ICU-Acquired Pneumonia After Cardiothoracic Surgery: Accuracy of Diagnostic Tools and Outcomes.

التفاصيل البيبلوغرافية
العنوان: Non-Ventilator ICU-Acquired Pneumonia After Cardiothoracic Surgery: Accuracy of Diagnostic Tools and Outcomes.
المؤلفون: Stéphan, François, Zarrouki, Youssef, Mougeot, Christine, Imbert, Audrey, Kortchinsky, Talna, Pilorge, Catherine, Rézaiguia-Delclaux, Saida
المصدر: Respiratory Care; Mar2016, Vol. 61 Issue 3, p324-332, 9p, 3 Diagrams, 3 Charts
مصطلحات موضوعية: PNEUMONIA diagnosis, SPUTUM microbiology, BRONCHOALVEOLAR lavage, BRONCHOSCOPY, CARDIOVASCULAR surgery, CHI-squared test, CONFIDENCE intervals, CLINICAL pathology, FISHER exact test, FLUIDS, INTENSIVE care units, LONGITUDINAL method, MICROBIOLOGICAL techniques, MICROSCOPY, PROBABILITY theory, RESEARCH funding, SURGICAL complications, T-test (Statistics), DATA analysis, DATA analysis software, DESCRIPTIVE statistics, MANN Whitney U Test
مستخلص: BACKGROUND: Non-ventilator ICU-acquired pneumonia after cardiothoracic surgery is challenging to diagnose, and little is known about its impact on patient outcomes. Here, our primary objective was to compare the sensitivity and specificity of cultures of 2 types of fiberoptic bronchoscopy (FOB) specimens: endotracheal aspirates (FOB-EA) and bronchoalveolar lavage fluid (FOB-BAL). The secondary objectives were to evaluate the sensitivity and specificity of spontaneous sputum cultures and of the modified Clinical Pulmonary Infection Score (CPIS) and to describe patient outcomes. METHODS: We conducted a prospective observational study of consecutive cardiothoracic surgery subjects with suspected non-ventilator ICU-acquired pneumonia. Using FOB-BAL cultures ≥104 cfu/mL as the reference standard, we evaluated the accuracy of FOB-EA ≥105 cfu/mL and spontaneous sputum ≥107 cfu/mL. On the day of FOB, we determined the modified CPIS. Mortality and antibiotic treatments were recorded. RESULTS: Of 105 subjects, 57 (54.3%) received a diagnosis of non-ventilator ICU-acquired pneumonia. FOB-EA cultures had 82% (95% CI 69-91%) sensitivity and 100% (95% CI 89-100%) specificity and were significantly less sensitive than FOB-BAL cultures (P < .004). Spontaneous sputum was obtained from one-third of subjects. Spontaneous sputum cultures had 82% (95% CI 56-95%) sensitivity and 94% (95% CI 68-100%) specificity and were non-significantly less sensitive than FOB-BAL (P = .061). A modified CPIS >6 had 42% (95% CI 29-56%) sensitivity and 87% (95% CI 74-95%) specificity for non-ventilator ICU-acquired pneumonia. Antibiotic therapy was stopped in all subjects without non-ventilator ICU-acquired pneumonia, after 1.6 ± 1.2 d, without deleterious effects. CONCLUSIONS: The modified CPIS has low diagnostic accuracy for non-ventilator ICU-acquired pneumonia. FOB-EA cultures perform less well than do FOB-BAL cultures for diagnosing non-ventilator ICU-acquired pneumonia. Spontaneous sputum is valuable when FOB cannot be performed but could be obtained in only a minority of subjects. When cultures are negative, antibiotic discontinuation is safe. [ABSTRACT FROM AUTHOR]
Copyright of Respiratory Care is the property of American Association for Respiratory Care and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
قاعدة البيانات: Supplemental Index
الوصف
تدمد:00201324
DOI:10.4187/respcare.04059